版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
1、Automaticself-cleaningfilterOperationmanualModelCNAF-JTBeijingLuolun(ExcelEthics)filtrationEquipmenttechnologyCo.,LtdProductintroductionFiltrationisoneimportantpartofwaterpurification,whichfilterstheimpurityinordertoachievethepurposeofwatertreatmentorprotection.Traditionalnetfiltrationapproacheshave
2、beenwidelyappliedinwatertreatmentandindustrialwaterrecyclingsystemowingtoitsgoodfiltrationresultandsmallresistance.However,theseapproacheshavethelimitofvolumeofimpuritytobetreated,easilyblockedandcomplicatedcleaningprocesswhichmustbecleanedafterthewholesystemisdisassembly.Thiskindofcleaningprocesslo
3、sesthemonitorandlowerstheautomationforwholesystem.Automaticcleaningfiltrationfiltersthegreywaterandautomaticallycleansthefilterwithoutstoppingsupplyingthewater.Thesystemisfullyautomaticandtreatsbigvolumeofgreywater.SolenoidmotorsStainlesssteelsbrushPicture1ServiceablerangeJT-automaticself-cleaningfi
4、lterwidelyappliedincircleoracycliccoolingwaterssystem,heatexchangingsystem,centralair-conditioningsystem,andcentralheatingsystem,hot-waterboiler,whichareusedtoprotectcoolingequipment,heatingexchangingsystem,airconditionandboiler.Itissuitabletoindustrycirculatingwaterfiltrations,suchassteelsystem,pet
5、roleumchemicalindustry,metallurgy,electron,papermaking,food.ThisequipmentrequestswatertemperatureflowthefiltercantCsurpass95Therequestofwaterquality:Thesuspendedsubstanceinwaterissmallerthan60mg/L,suspendedsubstancecanbeallowedtoachieve110mg/Lintheshortadequatetime.Ifthewaterqualitycannotmeettherequ
6、irements,itneedstopretreatmentbeforeentertotheinlet.ProductfunctionsandcharacteristicsproductfunctionsAutomaticcleaningfiltrationsystemfiltersthegreywaterandautomaticallycleansthefilterwithoutstoppingsupplyingthewater.Thesystemhastwocontroltypes:Manualandautomatic.Automaticcontrol:Therearetwowaysfor
7、automaticcontrol.Oneistimerandtheotherispressuredifference.Setthetimeforthefiltrationonthetimer.Whenitfinishesthecleaningprocessstartsautomatically.Inthemeantime,thecontrolsystemcomparesthesystempressuredifferencewithpre-setpressuredifference.Ifbothdifferencesmeettogetherthesystemstartstheautomaticc
8、leaning.Thedurationissetbythetimer.Whenthecleaningfinishesthesystemgoesbacktotheinitialstateandisreadyforthenextcycle.Manualcontrol:Turntheswitchtothemanualanditstartstocleanthefiltermanually.Customerscanchooseanymodelofcontrolaccordingtotheneed.Pleaseseethedetailsofoperationintheoperationsection.pr
9、oductCharacteristicsThedefaultfilterfitnessis100micronsandoptionalfrom100micronsto3000microns.Moreover,itsfilterareaislarge,thepollutionalloadishigh,andusercansettingaccordingtoactualworkingcondition.Itiseasytooperateautomaticcleaningundertheelectronicmonitor.Allparametersforthecontrolsystemcanbeadj
10、usted.Thesystemhasdesignedfortheover-loadmotorprotector.Thesystemfeaturesinnon-stopsupplyofwaterwhenthecleaningisprocessed.Itconsumeslittlewatertoclean.Theamountofwaterusedislessthan1%ofthetotalamountofwater.Easytomaintainanduninstall.ThesystemisdesignedFrenchconnectionandeasy.Productmodeldescriptio
11、nsJT-automaticself-cleaningfiltersspecificationsisdistinguishedbyinsidenominaldiameterofwater3456810inletandoutlet,Conventionalproduceshavetwelvespecifications:12、14、16、18、20.PN=1.6MPaRepresentationofthespecificationsasfollowed:CNAF-JTPN(MPa)Insidenominaldiameter(inch)modelModelAutomaticself-cleanin
12、gfilterForexample:10JT-automaticself-cleaningfiltercanbeexpressedasCNAF-JT10-1.6ProductstructuredescriptionsAsshowninpicture1,weadoptthemechanical-electricalintegrationsystemdesignJT-automaticself-cleaningfilterismadeofdriver,controlcircuit(includingtheswitchofpressuredifference),filtration,cleaning
13、parts,Frenchconnectionetc.Electricalcontrol,controlcircuitanddischargevalvearethemainpartsforthecontrolsystemwhichoperatestheautomaticcleaningprocess.Controlcircuitismadeofswitchofpressuredifference,brassandconnectionetc.Thefilterisnormallymadeofstainlesssteelandcanbeotheroptionsaccordingtothewatert
14、emperatureandquality.ProductOutlook1、mountingdimensions(asshowninpicture2)Picture2Sharpchart,asshownintable1Table1ModelpipediameterJJlJ2YY1KWeight(inch)mmmmmmmmmmmm(Kg)CNAF-JT03388637671868325767387CNAF-JT044936411770683257673106CNAF-JT0551018461852683257673132CNAF-JT0661111523951744303725197CNAF-JT
15、08814277151237820349777248CNAF-JT101016858531439874393826360CNAF-JT121218159441569939458908486CNAF-JT141420821094179210265451010653CNAF-JT161623601239201910986081111765CNAF-JT181826321389224511996791213814CNAF-JT202029191547248312887171250920CNAF-JT24243510186528641458864144010387technicalperformanc
16、eparametersTechnicalparametersandmainconstructionsizeasshownintable2:modelparameter、JT03JT04JT05JT06JT08JT10JT12JT14JT16JT18JT20JT24workingvoltalternatingcurrent380V50Hzpower(kW)50.250.370.370.370.550.750.752.202.20Economicoutput(m3/h)45651051502604105908001050132016302350minimumoperating
17、pressure(MPa)0.1maximaloperatingpressure(MPa)1.6Filteringarea(cm2)116513672095301452707867114141555220344257513178642295Inletandoutletinsidenominaldiameter(mm)DN80DN100DN125DN150DN200DN250DN300DN350DN400DN450DN500DN600washwatervalveinsidenominaldiameter(mm)DN50-DN80thetimeforpollutiondischarge(s)106
18、0MattersneedattentionThedevicehasbeendebuggedbeforeleavingthefactory,itcanrundirectlyWwhihleentuhseing.equipmentparameterscannotsatisfytheuserrequest,theusercanactaccordingtotheactualoperatingmodetosetvariousparameters,orselectswayssuchashandcontrol,automatictimingcontroltocarryontheworkcorrespondin
19、gly.Whenrunsforthefirsttime,pleasecarryonaccordingtothebelowstep:Inspectsthefilterwhethertobeatthenormalworkcondition:Whetherthepollutiondischargetubehasbeenconnected,lengthofblowdownpipecantsurpass15meters,cannothavetheupwardinclinationangle,inordertoavoidhasthebackpressure.Examineeachjointwhetherr
20、eliable.Examinethattheelectriccabinetisdry.Power-on,thegreenpowerlightturnbright,indicatedthatelectricalcontrolledpartisatthenormalworkcondition,theequipmentcanputintoserviceNotes:maintainhandsdrywhileinsertstheelectricpowersource.Meanwhilemaintainelectriccontrolpartisdryduringthefilterworking,canno
21、tletthewaterenterinto.InstallandtransportPowerconnectionPleasechoosepowersocketfollowingthehintsaboutvoltageandpoweronthenameplate,select1.5mm2or2mm2wireandswitch-ininputterminaltothebottomoftheelectricalcabinet,asshowninpicture3.Pleaseinstallthetriphasepoweraccordingtothepicture3.BlackBlackBlackBla
22、ckYello123456LIL2L3NPEPicture3TheconnectionaboutcontrolboxElectricalmotorconnection:Theelectricalmotortriple-phaselineswitch-inU3,V3,andW3separately;thegroundwireswitch-inPE.Asshowninpicture4,theyswitch-inendboardontherightoftheelectricallycontrolledboxbottom.Solenoidpilotactuatedvalveconnection:the
23、redlineswitch-intheelectricallycontrolledbox104terminator,theblacklinetoswitch-intheelectricallycontrolledboxNterminator.Theolivinelinesswitch-intheelectricallycontrolledboxPEterminator.Asshowninpicture4,theyswitch-inendboardontherightoftheelectricallycontrolledboxbottom.Pressuregageswitchconnection
24、:TheNOterminatorswitch-intheelectricallycontrolledbox102terminator,theCOMterminationswitch-intheelectricallycontrolledbox108terminator.Asshowninpicture4,theyswitch-inendboardontherightoftheelectricallycontrolledboxbottom.ElectricmotorPressureswitchSolenoidpilotactuatedvalvePicture4Installationandpre
25、cautionThearrowindicatesthewaterflowdirection.Thefiltrationneedstobeinstalledbythisdirection.SewagepipeshouldbeFrenchconnectedontothewatersolenoidvalve.Thepipeshouldnotbelongerthan15metersandnoanglesallowedinordertoavoidthepressuredifference.Therearetwowaysoffilterinstallation.SeePicture57.Pleasenot
26、ethewaterflowdirectionmustbecorrectandthewatersolenoidvalveshouldbeinstalledatahorizontalleveloratlowerplaceinordertohaveafullcleaning.Automaish1-i:1h.ifilterbypassnot已:t上l已五工已cticinofth已;ittuwist上l已已rdii-已ctiijn=門工廣已foriiicis已Picture5Picture6_j_、pollutiondischargeisdown_Thefiltershoulduseatandemcom
27、bination.Toguaranteeuninterruptedwatersupplywhenoverhaulingthedeviceforwatertreatment,Wesuggestyouestablishedthebypassinthesystem,theinletandoutletoffilterandthebypassshouldinstallthecut-offtousethevalve,forexample:Thecut-offvalve,thereedvalveandsoon.Theselectionoffilterspecificationshouldmatchtothe
28、pipelineinstallation.Forexample:Thesystemcaliberis10,thusyoumaychoosefilterofspecification10.Whentheflowratecannotsatisfythepipelinerequests,usersmayusethewayofparallelconnection,asshowninpicture7Picture7Thefiltershouldinstallbeforethewaterequipmentwhichsystemneedtobeprotected,theinstallationshoulda
29、pproachtotheprotecteddeviceasfaraspossible.Installthecheckvalveintheoutletofthefilterintheplacemaycausebackflow.Inthedynamicsystem,thefiltershouldinstallbetweenthepumpandtheequipment,moreapproachestheequipmenttobebetter.IfpressurebetweenthepumpandequipmentsurpassesfiltersEP,shouldinstallthefilterbef
30、orethepump,andapproachthepumpasfaraspossible.InstallationoftheelectricalControllers:Whenelectriccontrolleavingtheplant,tobefixedaccordingtodefaultposition.Iftheactualpositionisdifferentfromthedefaultposition,userscandismantlefourerectionboltsusedfixedelectriccabinet,afteradjustingtheelectriccabinetb
31、racketandelectriccabinetscorrectdirection,andthenfixthefourerectionbolts.Choosethereasonableinstallationenvironment,payattentiontowaterproofing,rainproof,andmoisture-proof.Beforeleavingtheplant,theproductshavebeendebugged,usershouldnotdisassembleordebugatwill.OperationSTserieshasmanualandautomaticwa
32、yofcleaning.Thecontrolpanelisasfollowsinthepicture10.FiltrationtimeCleaningtimeManualAutooooAlamControlPowerPicture10ManualTurnmanual/autotomanualposition.Seepicture10.Motorandwatercontrolareconnectedtothepower.Thewatervalveopensanditstarstoclean.Turnthemanual/autotoautothesystemgoesintoautomaticpro
33、cess.Manualcontrolisawaytocheckwhetherthemotorandwatervalveworkproperly.Ifthesystemcantcleannormallywhenitisundermanualanditcantdounderauto.AutoTurntoautoposition.Setthefiltrationtimeandcleaningtimeontimer.Thesetupfiguresaredisplayedinthebottomofthetimerandthecountingfiguresaredisplayedonthetopofthe
34、timer.Timersetting:Presstheselectbuttonandthefirstdigitpipeflashes.Pressthe“up”buttontoadjustthefigureandpresstheselectbutton.Theseconddigitpipeflashes.Usethiswaytoadjustallfiguresforthetime.Whenthesettingisdonethedigitpipewillflash8timesandthefiguresaresavedtothememorywherealldatawontbelosteventhep
35、owerisoff.Pressthestartbuttonthetimerbeginstocountthetime.Ifthepowerisoffthetimerwillcountthetimewhenthepowerisbacknexttime.Thefiltrationtimemeasuresinminute.Themaximumtimeis9999minutes.Thecleaningtimemeasuresinsecond.Themaximumtimeis99.99seconds.Turntoautostatewhenthepowerison.Thefiltrationprocesss
36、tartsforadurationthatsetsinthetimer.Inthemeanwhilethepressuredifferenceswitchalsocomparesthepressuredifferencebetweentherealsituationandthefigurethatissetupinitially.Ifthedurationoftimeforfiltrationisupbutthepressuredifferenceshaventmetthenthesystemalsostartstoopenthecleaningvalveandbegintoclean.The
37、timeofcleaningisbeingcounted.Whenthetimeofcleaningendsthecleaningvalvecloses.Newcyclebegins.Intheothersituation,iftheofdurationoftimesetonthetimerhasntelapsedandthepressuredifferenceshavemeteachotherthenthesystemalsoopenthecleaningvalvesandstartscleaning.Thefilterstopscountingandcleaningprocessstart
38、stocountthetime.Thesystemwillrepeattheprocesstimebytime.Picture11AdjustmentofPressuredifferenceindicator(Picture11)Thepressuredifferenceindicatorhasbeensetinthefactoryandthepressuredifferenceis0.5Bar.Thereisanadjustingscrewonthelowpressureendoftheindicator.Oneclockwiseturnincreasethepressuredifferen
39、ceby0.06Bar.Oneanticlockwiseturndecreasethepressuredifferenceby0.06Bar.E.g.Ifthecurrentpressuredifferenceis0.5Barandneedstobechangedto0.2Bar,5anticlockwiseturnsareneeded.Viceversa.Adjustmentofpressuredifference:theindicatorcanbeuninstalledfromthesystemandconnectitshighpressureendtothepressure-increa
40、seequipmentandpressuremeteriftheindicatorneedstobeadjusted.Observethemovementofindicator.Increasethepressuretothefigureneededonthehighpressureend.E.g.0.5Barisneededforthepressuredifferenceindicator.Turntheadjustingscrewwhenthepressuremeterreads0.5Bar.Ifthescrewmovestothefigureof0.5Baritisthefigureforthepressuredifferenceindicator.ServicePromiseBeijingLuolun(ExcelEthics)filtrationEquipmenttechnologyCo.,regardsqualityandcreditstandingaslife,insistsonthecorporateprinciple“Createwithheart,Basedonthemarket”.Aimatmeetingcustomersneed,wemakethefollowingPromise:Guaranteeperiodforproduct
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 物聯網標識解析的跨平臺與跨領域研究-洞察闡釋
- 移動文檔版權保護機制-洞察闡釋
- 物聯網對齊線在工業0中的應用研究-洞察闡釋
- 在線家政市場細分策略-洞察闡釋
- 合同約定贈予協議書范本
- 合同簽約履約分離協議書
- 門店啟動合同協議書范本
- 外墻翻新合同協議書模板
- 轉租合同協議書范本模板
- 藝術培訓機構合同協議書
- DL∕T 741-2019 架空輸電線路運行規程
- 【廣州浪奇公司存貨內部控制缺陷的案例探析8100字(論文)】
- 潛水主題素材課件
- 三供一業移交政策規定
- 小班活動學情分析
- 國家開放大學《合同法》章節測試參考答案
- 風電施工安全生產事故案例匯編(第一期)
- 固定資產使用與維護制度
- (正式版)JBT 14694-2024 電氣絕緣用合成有機酯與結構材料的相容性試驗方法
- MOOC 工程制圖-重慶大學 中國大學慕課答案
- 銀川市安置房買賣合同合集3篇
評論
0/150
提交評論