1、建設工程檢測埋地排水管驗收指標鋼筋混凝土排水管技術要求(GB/T 11836-2009)公稱內徑D0/有效長度L/級管級管級管200200030121830152330192930030152330192930274140040172640274140355350050213250324850446860055253860406060538070060284270477170629380070335080548180711079007537569061929080120100085406010069100100891341100954466110741101109814712001004872

2、120811201201071611350115558313590135135122183140011757860.06140931400.101401261890.101500125609015099150150135203160013564961601061591601442161650140669916511017016514822218001507211018012018018016224317 埋地排水管鋼筋混凝土排水管技術要求(續)(GB/T 11836-2009)公稱內徑D0/有效長度L/級管級管級管2000200017080120200134200200181272220018

3、58413022014522022019929924002009014023015223023021732626002201041562351722602352353532800235112168255185280255254381300025012018027519830027527341032002651281922902113172902924383500290140210320231347320321482說明1、尺寸允許偏差,詳見GB/T11836-2009標準表4表11。2、內水壓力檢驗:管子在進行內水壓力檢驗時,在規定的檢驗水壓力下允許有潮片,但潮片面積不得大于總表面積的5%,且

4、不得有水珠流淌。(注:壁厚大于等于150的雨水管,可不作內水壓力檢驗)判定規則:1)外觀質量和尺寸偏差:10根受檢管子中,A類項目必須合格;每項B類項目的超差不超過2根,B類項目的超差不超過2項,則判定該批產品的外觀質量和尺寸偏差合格。 2)力學性能:內水壓力和外壓載荷檢驗分別符合GB/T11836-2009標準6.4、6.5規定時,則判該批產品的力學性能合格。如內水壓力或外壓載荷檢驗不符合標準規定時,允許從同批產品抽取2根管子進行復驗。復驗結果如全部符合標準規定時,則判該批產品力學性能合格。復檢結果如仍有1根管子不符合標準規定時,則判該批產品力學性能不合格。17 埋地排水管鋼筋混凝土排水管技

5、術要求(續)(GB/T 11836-2009)公稱內徑DN管壁厚度h裂縫載荷破壞載荷內水壓力級級級級級級壓力MPa內驗要求優等品一等品合格品6006029.543.559.639.654.474.50.1完好、無潮片潮片面積小于總表面積的2%潮片面積小于總表面積的5%7007034.750.467.343.463.084.18008039.457.977.449.372.496.89009044.365.587.255.481.9109.0100010049.370.394.361.687.9117.9110011049.672.7108.374.4109.1162.5120012053.97

6、8.2119.280.9117.3178.8135013560.090.8134.390.0136.2201.5150015066.1101.7150.899.2152.6226.5165016572.0112.8165.8108.0169.2250.1180018078.0124.3182.9117.0186.5279.3200020085.4139.5203.5128.1218.1327.3220022092.8154.9226.6139.2249.5368.5240024099.9170.8-149.9279.3-2600260106.9187.0-160.4324.4-28002801

7、13.6203.7-171.2357.4-3000300124.1-205.1-1、尺寸允許偏差:詳見KG/T 640-1996 標準表7表102、判定規則: 1)尺寸:從每批樣品中抽樣10根進行檢驗,不符合某一等級的管子超過三根,則視該批產品未達到該等級標準。 2)力學性能:外壓裂縫荷載和內水壓力檢驗,如果一項檢驗不合格,則允許再抽取二根進行復檢;如其中仍有一根不合格,則判定該批不品不合格。17 埋地排水管預應力鋼筋混凝土管抗裂內壓檢驗指標(GB/T19685-2005)管型公稱內徑()工作壓力/MPa0.40.60.81.01.21.41.61.82.0內襯式管4000.700.951.1

8、81.461.742.022.302.582.865000.700.951.181.461.742.022.302.582.866000.700.951.181.461.742.022.302.582.867000.700.951.181.461.742.022.302.582.868000.700.951.181.461.752.032.312.592.879000.700.951.191.491.772.052.332.612.8910000.700.951.211.501.782.062.342.622.9012000.700.941.221.531.812.092.372.652.93

9、14000.700.971.251.601.882.162.442.723.00埋置式管12000.881.161.441.722.002.282.562.843.1214000.901.181.461.742.022.302.582.863.1416000.921.201.481.762.042.322.602.883.1618000.941.221.501.782.062.342.622.903.1820000.981.261.541.822.102.382.662.943.2222001.001.281.561.842.122.402.682.963.2424001.141.421.70

10、1.982.262.542.823.103.3826001.161.441.722.002.282.562.843.123.4028001.181.461.742.022.302.582.863.143.4230001.201.481.762.042.322.602.883.163.4432001.201.481.762.042.322.602.883.163.4434001.211.491.772.052.332.612.893.173.4536001.261.541.822.102.382.662.943.223.5038001.251.531.812.092.372.652.933.21

11、3.4940001.261.541.822.102.382.662.943.223.50注1:抗裂檢驗內壓公式:P t =(A ppe+f t k A n)/b0注2:表列數據適用于鋪設條件為:管頂覆土深度0.82m,土弧基礎(90);2輛汽-20并列;注3:制造廠應根據管線的實際鋪設使用條件進行管子結構驗算;17 埋地排水管預應力混凝土管相關檢驗指標(一階段管抗裂內壓檢驗指標GB5696-2006)公稱內徑/工作壓力/MPa0.20.40.60.81.01.24000.761.031.281.541.701.865000.841.111.341.571.761.956000.891.161.

12、391.621.812.007000.971.241.471.701.892.088000.991.261.491.731.922.109001.011.281.511.741.932.1110001.021.291.521.751.942.1212001.061.331.561.801.992.1714001.101.371.601.842.032.2116001.12(1.27)1.39(1.54)1.62(1.77)1.85(2.00)2.04(2.19)2.22(2.37)18001.12(1.27)1.39(1.54)1.62(1.77)1.85(2.00)2.04(2.19)2.2

13、2(2.37)20001.12(1.27)1.39(1.54)1.62(1.77)1.85(2.00)2.04(2.19)2.22(2.37)注1:抗裂檢驗內壓公式:P t =(A ppe+f t k A cm)/cpb0 臥式水壓試驗時, P t應扣除管道和水重影響:立式水壓試驗時, P t應扣除管子垂直高度水柱的影響。注2:本表數據適用輔設條件:素土基礎、管頂覆土深度0.82m,地面允許2輛汽-20并列;注3:制造廠應根據管線的實際鋪設使用條件進行管子結構驗算;注4:表列帶括弧的數據為立式水壓檢驗指標,其余為臥式水壓檢驗指標17 埋地排水管預應力混凝土管相關檢驗指標(三階段管抗裂內壓檢驗指

14、標GB5696-2006)公稱內徑/工作壓力/MPa0.20.40.60.81.01.24000.680.951.181.411.601.85000.751.021.251.491.671.866000.781.051.291.521.711.897000.841.111.341.571.761.948000.871.141.381.611.791.989000.881.151.381.611.801.9810000.921.191.421.651.842.0212000.981.221.451.681.872.0514000.981.251.491.721.912.0916000.98(1.

15、13)1.25(1.40)1.49(1.64)1.72(1.87)1.91(2.06)2.09(2.24)18000.98(1.13)1.25(1.40)1.49(1.64)1.72(1.87)1.91(2.06)2.09(2.24)20000.98(1.13)1.25(1.40)1.49(1.64)1.72(1.87)1.91(2.06)2.09(2.24)22001.03(1.22)1.30(1.49)1.54(1.73)1.77(1.96)-24001.03(1.23)1.30(1.50)1.57(1.76)-26001.03(1.25)1.30(1.52)-28001.03(1.25)

16、1.30(1.52)-30001.03(1.25)1.30(1.53)-注1:抗裂檢驗內壓公式:P t =(A ppe+f t k A cm)/cpb0 臥式水壓試驗時, P t應扣除管道和水重影響:立式水壓試驗時, P t應扣除管子垂直高度水柱的影響。注2:本表數據適用輔設條件:素土基礎、管頂覆土深度0.82m,地面允許2輛汽-20并列;注3:制造廠應根據管線的實際鋪設使用條件進行管子結構驗算;注4:表列帶括弧的數據為立式水壓檢驗指標,其余為臥式水壓檢驗指標17 埋地排水管預應力混凝土管相關檢驗指標 (抗滲性檢驗指標GB5696-2006)1、抗滲檢驗壓力值應為管道工作壓力的1.5倍,最低的抗滲檢驗

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
  • 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
  • 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論