1、目 錄一、工程概況 ··············································2二、工程設(shè)計(jì)要求 

2、3;············································21.保溫斜屋面 ····&

3、#183;········································22剛性屋面 ········

4、·····································23地下室內(nèi)墻 ···········

5、3;·································34地下室外墻 ···············&#

6、183;······························35地下室地面 ··················

7、···························36地下室頂板 ·····················

8、3;························3三、SBS防水卷材施工 ·······················

9、83;················31材料要求 ································&#

10、183;············32操作流程 ····································&

11、#183;········33操作工藝 ········································

12、·····34質(zhì)量標(biāo)準(zhǔn) ············································

13、;·45成品保護(hù) ·············································56應(yīng)注意的問題 ·&

14、#183;·······································5四、高分子涂料防水施工方案 ·······

15、3;···························71施工準(zhǔn)備 ·····················

16、83;·······················72操作工藝 ·························&#

17、183;···················83質(zhì)量標(biāo)準(zhǔn) ·····························&

18、#183;···············104成品保護(hù) ·································

19、;············10五、安全生產(chǎn)、文明施工保證措施 ······························111安全生產(chǎn)措施 ···&

20、#183;·····································112文明施工、環(huán)境保護(hù)措施 ·········

21、3;······················11一、工程概況工程名稱:寧波龍湖滟瀾海岸一期3#地塊一標(biāo)段工程地點(diǎn):寧波市北侖區(qū)春曉鎮(zhèn),地塊位于春曉中直河?xùn)|建設(shè)單位:寧波龍嘉房地產(chǎn)發(fā)展有限公司設(shè)計(jì)單位:中國聯(lián)合工程公司監(jiān)理單位:浙江省工程咨詢有限公司施工單位:紅陽建設(shè)集團(tuán)有限公司本工程位于寧波市北侖區(qū)春曉鎮(zhèn),地塊位于春曉中直河?xùn)|,總建筑面積90566。;屋面防水等級(jí):級(jí),工程

22、質(zhì)量要求以國標(biāo)GB502072002 屋面工程質(zhì)量驗(yàn)收規(guī)范為準(zhǔn)。洋房20#、34#、45#、50#樓為58層多層框架結(jié)構(gòu),別墅為23層,坡屋面+上人平屋面和不上人屋面,總體所用的是SBS卷材防水工程和涂料防水工程。地下室車庫底板下采用SBS瀝青防水卷材,外墻側(cè)面采用聚氨脂911防水涂膜,頂板面采用聚氨脂911防水涂膜和耐根穿刺改性瀝青防水卷材。二、工程設(shè)計(jì)要求設(shè)計(jì)要求:1、保溫斜屋面(保溫非上人屋面)現(xiàn)澆鋼筋混凝土屋面板隨搗隨抹;15厚1:3水泥砂漿找平層;1.5厚雙組分聚氨酯防水涂料(型)上翻300mm;3厚SBS改性瀝青防水卷材(聚酯胎聚乙烯膜型);40厚擠塑聚苯板保溫層(燃燒性能不低于B

23、型);10厚1:3水泥砂漿找平層;最薄處40厚C15細(xì)石混凝土(內(nèi)配6150*150鋼筋網(wǎng))保護(hù)層;1:3水泥砂漿臥瓦層, 最薄處20厚C15細(xì)石混凝土(內(nèi)配6150*150鋼筋網(wǎng));陶土瓦屋面.2、剛性屋面(保溫上人屋面)現(xiàn)澆鋼筋混凝土屋面板隨搗隨抹,設(shè)置與墻體同厚的C20混凝土導(dǎo)墻,高度超過室外完成面至少150;泡沫混凝土2%找坡最薄處30mm;20厚1:3水泥砂漿找平層,陰陽角抹R50圓弧;刷基層處理劑;在山墻四周、屋面管道周圍涂刷1.2 mm厚聚氨脂防水涂膜加強(qiáng)層,寬度至少250,涂刷高度超過完成面250,有攔桿處,刷到平面外外口; 1.5厚雙組分聚氨脂防水涂料(型)上翻300mm,(

24、建筑完成面以上);3mm厚SBS聚酯胎改性瀝青防水卷材防水層,泛水高度從結(jié)構(gòu)面算起500;40厚擠塑聚苯板保溫層(燃燒性能不低于B型);最薄處40厚C15細(xì)石混凝土(內(nèi)配6150*150鋼筋網(wǎng))保護(hù)層,壓實(shí)趕光,坡向地漏;3、 地下室側(cè)內(nèi)墻:鋼筋砼界面劑12厚RP15水泥砂漿打底掃毛8厚RP20水泥砂漿壓實(shí)粉光4、地下室外墻:鋼筋砼防水側(cè)墻,抗?jié)B等級(jí)C35P620厚1:2水泥砂漿找平填實(shí)找平3厚聚氨脂911防水涂料滿涂從底板返到邊20厚1:2.5水泥砂漿填實(shí)50厚膨脹聚苯板保護(hù)層120mm厚磚墻保護(hù) 500范圍內(nèi)素土回填。5、地下室地面(汽車庫):現(xiàn)澆鋼筋混凝土底板涂料3厚滲透結(jié)晶水泥基防水層

25、,沿側(cè)板上翻500,用量不小于1。8K/²最薄處30厚C20細(xì)砼找坡層最薄處50厚C25混凝土隨搗隨抹地坪耐磨漆二度(上翻120)。6、 地下室頂板(景觀屋面):鋼筋混凝土頂板隨搗隨抹平(抗?jié)B)最薄處30厚CL7.5輕集料混凝土找坡層基層整體1:1:2聚合物水泥膩?zhàn)?厚刮平2厚聚氨脂911防水涂膜,遇外墻卷起超過地坪完成面2504mm厚耐根穿刺改性瀝青防水卷材(型APP卷材,PY胎基,PE面),熱熔法鋪貼無紡布隔離層(0.2K/M)² 最薄處70厚C20細(xì)石混凝土,內(nèi)配6200雙向鋼筋網(wǎng)排水板土工布一層種植綠化土三、SBS防水卷材施工1、材料要求SBS改性瀝青防水卷材:產(chǎn)品

26、應(yīng)有出廠合格證及廠家檢驗(yàn)報(bào)告,按設(shè)計(jì)要求選用厚度、規(guī)格;材料進(jìn)場(chǎng)后按規(guī)范要求復(fù)檢;2、操作流程基層清理鋪貼卷材附加層熱熔鋪貼卷材熱熔封邊淋水試驗(yàn)作保護(hù)層3、操作工藝3.1 刷冷底子油一道,要求均勻、沒有透底; 3.2、附加層施工:女兒墻、水落口、管根、檐口、陰陽角等細(xì)部先做附加層,一般用熱熔法使用改性瀝青卷材施工,必須粘貼牢固。3.3 熱熔鋪貼卷材:按彈好標(biāo)準(zhǔn)線的位置,在卷材的一端用煤氣焊槍火焰將卷材涂蓋層熔融,隨即固定在基層表面,用焊槍對(duì)準(zhǔn)卷材卷和基層表面的夾角,距離交界處300mm左右,邊熔融涂蓋層邊跟隨熔融范圍緩慢地滾鋪改性瀝青卷材,卷材下面的空氣應(yīng)排盡,并粘結(jié)牢固,不得空鼓;卷材的長短

27、邊搭接不應(yīng)少于100mm,接縫處采用焊槍的火焰熔焊粘牢,邊緣部位必須溢出熱熔的改性瀝青膠。隨即刮封接口,防止出現(xiàn)張嘴和翹邊。3.4 瀝青防水卷材按設(shè)計(jì)要求施工完,應(yīng)進(jìn)行淋水試驗(yàn), 持續(xù)淋水試驗(yàn)2h后,檢查有無滲漏、積水現(xiàn)象,防水底面無滲漏為合格,合格后方可進(jìn)行下道工序的施工; 3.4卷材鋪貼方向應(yīng)符合下列規(guī)定:3.4.1、 屋面坡度小于3時(shí),卷材宜平行屋脊鋪貼。 3.4.2、 屋面坡度在3以上或屋面受震動(dòng)時(shí),卷材可平行或垂直屋脊鋪貼。 3.4.3、 上下層卷材不得相互垂直鋪貼。 3.4.4、熱熔鋪貼卷材時(shí),焊槍嘴應(yīng)處在成卷卷材與基層夾角中心線上,距粘貼面300mm左右處。3.4.5、雙層鋪貼防

28、水層,第二層鋪貼的卷材,必須與第一層卷材錯(cuò)開1/2寬,其操作方法與第一層方法相同。4 、質(zhì)量標(biāo)準(zhǔn)4.1 主控項(xiàng)目: 4.1.1、防水層所用卷材及其配套材料,必須符合設(shè)計(jì)要求。 4.1.2、 防水層不得有滲漏或積水現(xiàn)象。 4.1.3、 卷材防水層在天溝、檐溝、檐口、水落口、泛水、變形縫和伸出屋面管道的防水構(gòu)造,必須符合設(shè)計(jì)要求。4.2 一般項(xiàng)目: 4.2.1、 卷材防水層的搭接縫應(yīng)粘(焊)牢固,密封嚴(yán)密,不得有皺折、翹邊和鼓泡等缺陷;防水層的收頭應(yīng)與基層粘結(jié)并固定牢固,縫口封嚴(yán),不得翹邊。 4.2.2、 卷材防水層上的撒布材料和淺色涂料保護(hù)層應(yīng)鋪撒或涂刷均勻,粘結(jié)牢固;水泥砂漿、塊材或細(xì)石砼保護(hù)

29、層與卷材防水層間應(yīng)設(shè)置隔離層; 4.2.3、 排汽屋面的排汽道應(yīng)縱橫貫通,不得堵塞。排汽管應(yīng)安裝牢固,位置正確,封閉嚴(yán)密。 4.2.4、 卷材的鋪貼方向應(yīng)正確,卷材搭接寬度的允許偏差為-10mm。4.2.5、地下水位高于防水層的施工部位,應(yīng)先做好降低地下水位和排水工作,將地下水位降至防水層底標(biāo)高以下300mm,并保持到防水層施工完畢。 4.2.6、 鋪貼防水層的基層應(yīng)干燥、平整,并不得有起砂、空鼓、開裂等現(xiàn)象,陰陽角處應(yīng)做成圓弧形或鈍角。 4.2.7、 地面或墻面的預(yù)埋管件、變形縫等處應(yīng)進(jìn)行隱蔽工程檢查驗(yàn)收,使其符合設(shè)計(jì)和施工驗(yàn)收規(guī)范的要求。 4.2.8、 外防水外貼法施工時(shí),清出防水層接槎部

30、位,結(jié)構(gòu)表面應(yīng)按設(shè)計(jì)要求做找平層,干燥后方可做防水層。 4.2.9、 鋼筋混凝土底板下鋪貼油氈卷材防水層前,應(yīng)在墊層上抹好水泥砂漿找平層,待干燥后方可進(jìn)行防水層施工。4.2.10、 瀝青油氈卷材防水層施工的環(huán)境溫度不應(yīng)低于5。5、 成品保護(hù)5.1 已鋪貼好的卷材防水層,應(yīng)及時(shí)采取保護(hù)措施,不得損壞,以免造成隱患。5.2 穿過屋面、墻面等處的管根,不得損傷變位。5.3 變形縫、水落口等處施工中臨時(shí)堵塞的廢紙、麻繩、塑料布等,完工后應(yīng)及時(shí)清理出去,保持管內(nèi)、口內(nèi)暢通無阻。5.4 防水層施工完成后,應(yīng)及時(shí)做好保護(hù)層。6、 應(yīng)注意的問題6.1空鼓:卷材防水層空鼓,發(fā)生在找平層與卷材之間,且多在卷材的接

31、縫處,其原因是防水層中存有水分,找平層不干,含水率過大;空氣排除不徹底,卷材沒有粘貼牢固。施工中應(yīng)控制基層含水率,并應(yīng)把住各道工序的操作關(guān)。6.2滲漏:滲水、漏水發(fā)生在穿過屋面管根、出水口、伸縮縫和卷材搭接處等部位。伸縮縫未斷開,產(chǎn)生防水層撕裂;其他部位由于粘貼不牢、卷材松動(dòng)或襯墊材料不嚴(yán)、有空隙等;接搓處漏水原因是甩出的卷材未保護(hù)好,出現(xiàn)損傷和撕裂,或基層清理不干凈,卷材搭接長度不夠等。施工中應(yīng)加強(qiáng)檢查,嚴(yán)格執(zhí)行工藝規(guī)程認(rèn)真操作。6.2 操作工藝 6.2.1 工藝流程: 6.2.2 平面鋪貼卷材工藝流程:保護(hù)墻放線砌筑保護(hù)墻抹保護(hù)墻找平層抹墊層找平層養(yǎng)護(hù)清理噴涂冷底子油鋪貼附加SBS卷材鋪第

32、一層SBS卷材 立面鋪貼卷材工藝流程:拆除根部臨時(shí)保護(hù)墻結(jié)構(gòu)面抹找平層養(yǎng)護(hù)噴涂冷底子油接鋪陰陽角處附加層鋪第一層SBS卷材3厚聚氨脂911涂料(按,設(shè)計(jì)分層涂抹)底板(保護(hù)層) 保護(hù)墻放線:建筑物基礎(chǔ)底板墊層施工后,按施工圖測(cè)放保護(hù)墻位置線。 砌筑保護(hù)墻:按設(shè)計(jì)要求砌筑保護(hù)墻至基礎(chǔ)底板上平標(biāo)高以上200mm。為使墻體面防水卷材接槎,加砌四皮磚臨時(shí)保護(hù)墻,該四皮磚砌筑時(shí)用石灰砂漿,待做外墻體防水時(shí)拆除以滿足底板防水卷材與墻體防水涂料的搭接寬度。 結(jié)構(gòu)防水面基層抹找平層:為卷材粘貼牢固,在底板墊層、保護(hù)墻、結(jié)構(gòu)基體做防水面,應(yīng)抹找平層,使防水卷材鋪貼在一個(gè)平順的基面上。要求陰陽角抹成圓角。 找平層

33、養(yǎng)護(hù):找平層抹完后應(yīng)澆水養(yǎng)護(hù),使其強(qiáng)度上升后,經(jīng)干燥方可做防水層。 噴涂冷底子油:為使鋪貼瀝青防水卷材與基層結(jié)合,在鋪卷材前,應(yīng)在鋪貼面上,噴涂冷底子油兩道。 冷底子油配制比例和方法: 比例:重量比30%的瀝青:70%的汽油。 配制方法:將瀝青加熱至不起泡沫,使其脫水,冷卻至90,將汽油緩緩注入瀝青中,隨注入隨攪拌至瀝青全部溶解為止。 鋪貼卷材防水層 2.9.1 平面鋪貼卷材:鋪貼卷材前,宜使基層表面干燥,先噴冷底子油結(jié)合層兩道,然后根據(jù)卷材規(guī)格及搭接要求彈線,按線分層鋪設(shè),鋪貼卷材應(yīng)符合下列要求: 2.9.1.1 粘貼卷材的瀝青膠結(jié)材料的厚度一般為1.52.5mm。 2.9.1.2 卷材搭接

34、長度:長邊不應(yīng)小于100mm,短邊不應(yīng)小于150mm。上下兩層和相鄰兩幅卷材的接縫應(yīng)錯(cuò)開,上下層卷材不得相互垂直鋪貼。2.9.1.3 在平面與立面的轉(zhuǎn)角處,卷材的接縫應(yīng)留在平面上距立面不小于600mm處。 2.9.1.4 在所有轉(zhuǎn)角處均應(yīng)鋪貼附加層。附加層可用兩層同樣的卷材,也可用一層抗拉強(qiáng)度較高的卷材。附加層應(yīng)按加固處的形狀仔細(xì)粘貼緊密。 2.7.1.5 平面與立面結(jié)構(gòu)施工縫處,防水卷材接槎的處理。2.9.2 立面防水涂料:鋪貼前宜使基層表面干燥,噴冷底子油,干燥后即可滿涂911防水涂料,其做法要求如下:2.9.2.13mm厚聚氨脂911防水涂料滿涂從底板返到邊,驗(yàn)收合格40厚膨脹聚苯板保護(hù)

35、層砌筑120mm厚保護(hù)磚墻。2.9.2.2在結(jié)構(gòu)施工前,應(yīng)將永久性保護(hù)墻砌筑在與需防水結(jié)構(gòu)同一墊層上。保護(hù)墻貼防水卷材面應(yīng)先抹13水泥砂漿找平層,干燥后噴涂冷底子油,干燥后即可鋪貼油氈卷材。卷材鋪貼必須分層,先鋪貼立面,后鋪貼平面,鋪貼立面時(shí)應(yīng)先鋪轉(zhuǎn)角,后鋪大面;卷材防水層鋪完后,應(yīng)按規(guī)范或設(shè)計(jì)要求做水泥砂漿或混凝土保護(hù)層,一般在立面上應(yīng)在涂刷防水層最后一層瀝青膠結(jié)材料時(shí),粘上干凈的粗砂、 待冷卻后,抹一層1020mm厚的13水泥砂漿保護(hù)層;在平面上可鋪設(shè)一層3050mm厚的細(xì)石混凝土保護(hù)層。四、高分子涂料防水施工方案1 施工準(zhǔn)備 1.1 材料及要求 1.1.1 聚氨酯防水涂料,應(yīng)具有出廠合格

36、證及廠家產(chǎn)品的認(rèn)證文件,并復(fù)驗(yàn)以下技術(shù)性能。 聚氨酯防水涂料,以甲組份及乙組份桶裝出廠;甲組份:異氰酸基含量以3.5±0.2%為宜。 乙組份:羥基含量以0.7±0.1%為宜。 兩組份材料應(yīng)分別保管,存放在室內(nèi)通風(fēng)干燥處,貯期甲組份為6個(gè)月,乙組份為12個(gè)月,使用時(shí)甲組份和乙組份料按11的比例配合,形成聚氨酯防水涂料,技術(shù)性能指標(biāo)如下: 固體含量: 93% 抗拉強(qiáng)度: 0.6MPa 延伸率: 300% 低溫柔度:在-20繞20mm圓棒無裂紋 耐熱度: 80不流淌 不透水性: >0.2MPa 干燥時(shí)間: 16h 1.1.2 輔助材料: 1 磷酸:用于做緩凝劑 1 二月桂酸

37、二丁基錫:用于做促凝劑。 1 二甲苯或醋酸乙酯:用于稀釋和清洗工具。 1 水泥、325號(hào)普通硅酸鹽水泥,用于配制水泥砂漿抹保護(hù)層。 1 中砂:圓粒中砂,粒徑23mm,含泥量不大于3%;用于配制水泥砂漿抹防護(hù)層。 1.2 主要機(jī)具: 1.2.1 電動(dòng)機(jī)具:電動(dòng)攪拌器。 1.2.2 手用工具:攪拌桶、小鐵桶、小平鏟、塑料或橡膠刮板、滾動(dòng)刷、毛刷、彈簧秤、消防器材等。 1.3 作業(yè)條件: 1.3.1 地下防水層聚氨酯防水涂料冷作業(yè)施工,在地下水位較高的條件下涂刷防水層前,應(yīng)先降低地下水位,做好排水處理,使地下水位降至防水層操作標(biāo)高以下300mm,并保持到防水層施工完。 1.3.2 涂刷防水層的基層應(yīng)

38、按設(shè)計(jì)抹好找平層,要求抹平、壓光、堅(jiān)實(shí)平整,不起砂,含水率低于9%,陰陽角處應(yīng)抹成圓弧角。 1.3.3 涂刷防水層前應(yīng)將涂刷面上的塵土、雜物,殘留的灰漿硬塊,有突出的部分處理、清掃干凈。 1.3.4 涂刷聚氨酯不得在淋雨的條件下施工,施工的環(huán)境溫度不應(yīng)低于5,操作時(shí)嚴(yán)禁煙火。2 操作工藝 2.1 工藝流程:基層清理涂刷底膠涂膜防水層施工做保護(hù)層 2.2 基層處理:涂刷防水層施工前,先將基層表面的雜物、砂漿硬塊等清掃干凈,并用干凈的濕布擦一次,經(jīng)檢查基層無不平、空裂,起砂等缺陷,方可進(jìn)行下道工序。 2.3 涂刷底膠(相當(dāng)于冷底子油): 2.3.1 底膠(基層處理劑)配制:先將聚氨酯甲料、乙料和二

39、甲苯以11.52的比例(重量比)配合攪拌均勻,配好的料在2h內(nèi)用完。 2.3.2 底膠涂刷:將配制好的底膠料,用長把滾刷均勻涂刷在基層表面,涂刷量為0.3kg/m2左右,涂刷后約4h手感不粘時(shí),即可做下道工序。 2.4 涂膜防水層施工: 2.4.1 材料配制:聚氨酯按甲料、乙料和二甲苯以11.50.3的比例(重量比)配合,用電動(dòng)攪拌器強(qiáng)制攪拌35min,至充分拌合均勻即可使用。配好的混合料應(yīng)2h內(nèi)用完,不可時(shí)間過長。 2.4.2 附加涂膜層:穿過墻、頂、地的管根部,地漏、排水口、陰陽角,變形縫并薄弱部位,應(yīng)在涂膜層大面積施工前,先做好上述部位的增強(qiáng)涂層(附加層)。 附加涂層做法:是在涂膜附加層中鋪設(shè)玻璃纖維布,涂膜操作時(shí)用板刷刮涂料驅(qū)除氣泡,將玻璃纖維布緊密地粘貼在基層上,陰陽角部位一般為條形,管根為塊形,三面角,應(yīng)裁成塊形布鋪設(shè),可多次涂刷涂膜。 2.4.3 涂刷第一道涂膜:在前一道涂膜加固層的材料固化并干燥后,應(yīng)先檢查其附加層部位有無殘留的氣孔或氣泡,如沒有,即可涂刷第一層涂膜;如有氣孔或氣

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

評(píng)論

0/150

提交評(píng)論