文檔簡介
1、加氣混凝土單一保溫節能墻體體系的再議論顧同曾(北京市建筑設計研究院,北京 100045)摘 要 本文對加氣混凝土單一保溫節能墻體體系從我國不同氣候區的使用、經濟及技術方面進行了論述,得出了以下結論:加氣混凝土制品作為單一墻體材料節能體系,運用不同密度和厚度的產品可以滿足當前我國各個氣候區規范對外墻的熱工性能要求;與幾種典型的外保溫復合墻體相比,在采用近似墻厚和熱工性能的前提下,無論社會效益和經濟效益,單一墻體節能體系優勢明顯;從生產技術、配套構件及有關產品標準等方面看,、大力推廣應用該節能體系的條件已經成熟;同時該體系也存在一定的問題,如在嚴寒地區,特別是A區的應用雖有優勢,但不能簡單地僅靠增
2、加墻厚來解決所有問題,還應補充其它措施。關鍵詞 加氣混凝土;單一保溫節能墻體;氣候區;經濟;技術 中圖分類號TU528.2 文獻標識碼 A Re-discussion on Aerated Concrete-based Single Insulation and Energy Efficiency Wall System GU Tong-zeng (Beijing Institute of Architecture Design, Beijing 100045, China)Abstract In this paper, aerated concrete single insulation a
3、nd energy efficiency wall system was demonstrated in the aspects of utility in different climate areas, economy and technology. It was concluded that as single insulation and energy efficiency wall system, aerated concrete with different densities and thicknesses could meet demands of thermal perfor
4、mance regulations in each climate area. Compared with typical heat preservation complex walls, the energy-saving effect of this system had obvious advantages, no matter for social and economic benefits, provided with almost same wall thickness and thermal performance. In consideration of production
5、techniques, supporting components and relative products standards, it was time to promote this energy efficiency system. Meanwhile, this system had disadvantages in cold area, although its application in A area had advantages, the problem could not be solved by increasing the wall thickness only, ot
6、her measures would also be needed.Keywords aerated concrete, single insulation and energy efficiency wall system, climate area, economy, technology2005年筆者曾在中國建設報發表過一篇題為應大力研發和應用單一保溫墻體節能體系的拙作,旨在節約資源、簡化施工工序、降低造價、充分利廢、改善環境,推崇加氣混凝土單一保溫墻體的外墻節能體系。這種材料的發明起源于德國,他們在20世紀20年代研制了灰砂磚,即將磨細石灰和砂子經過混合、成型,高壓養護制成一種實心磚以
7、替代傳統的粘土磚。1924年瑞典人在這些材料中加入鋁粉制成加氣混凝土并于1929年以工業化方法進行生產,最初的商品名為“伊通”(YTONG,Y是這個廠址所在城市的第1個字母,TONG是瑞典文水泥的后綴)。而后,在瑞典又發展了另一種叫“西波列克斯”(siporex)品牌的加氣混凝土。再后來,在德國、英國、荷蘭等地發展了各種品牌的加氣混凝土制品,尤其在二次收稿日期2008-08-15作者簡介 顧同曾(1933-),男,大學,教授級高級建筑師聯系方式 世界大戰后,此種制品在世界各國大規模發展起來。用這種制品最早修建的建筑是于20世紀30年代初建于瑞典斯德哥爾摩遠郊的1棟2層住宅,內承重墻和外墻均采用
8、B05級的產品,至今已有70多年的歷史。我國于1965年引進了瑞典“siporex”專利,1967年正式投產,至今也已有40多年的歷史(我國在引進國外專利之前已研發了這種產品,主要為板材,1966年在北京第三建筑公司修建了1棟由加氣混凝土板材承重的3層宿舍樓,建筑面積為780 m2)。引進專利后,最早的產品也是板材,如屋面板應用于北京月壇一條街,大部分墻板應用于幾個大型發電廠的外墻,如軍糧城電廠、涉縣電廠、娘子關電廠和包頭106電廠(這一電廠外墻采用鋼構構架和鋼筋混凝土構架組裝大板,每塊板面積達20-30m2)。從20世紀70年代開始,北京大量推行這種節能墻體,主要是內外墻板,應用建筑有北京加
9、氣廠辦公樓、白家莊建材局的家屬宿舍樓(這2棟建筑內外墻、屋面板、樓板都是加氣混凝土制品),以及一大批高層住宅和公共建筑,如安定門小區、總參住宅、東大橋10樓、交通部住宅、糖業煙酒公司、儲運公司倉庫等;20世紀80年代修建了著名的大型公共建筑建筑面積達25 000 m2的國際展覽中心,該建筑為一體化外墻,只是當時沒有突出“節能”這個名稱而已,在80年代北京加氣混凝土廠建立了拼裝大板生產線以及專用運輸車輛,板材最大尺寸為6m×4.8m的大板;20世紀90年代,北京正式執行節能30%的標準,北京市建筑設計院與北京市加氣混凝土三廠(后改名為北京現代建筑材料有限責任公司)合作,在北京市科委、建
10、委的支持下,由過去的僅使用加氣構件發展成建筑體系。在該廠修建了1棟3 300 m2的6層“抗震、節能新體系住宅”:外墻采用B06級墻厚300 mm的加氣混凝土砌塊、屋頂采用加氣混凝土屋面板、承重墻采用粉煤灰磚,該建筑的節能指標超過50,至今已使用16年有余,效果良好。 近20年來,加氣混凝土行業在我國得到了很大發展,但人們心中僅把它看成是一種輕質墻體材料,很少把它與節能聯系起來,甚至有些城市還不敢把它用作外墻。近10年來,各種外墻保溫體系發展迅速,絕大部分都是復合墻體,即將保溫材料復合在傳統墻體材料的外表面或內表面,較為普遍采用的保溫材料是泡沫聚苯乙烯板。保溫墻體的應用無疑對我國建筑節能事業而
11、言是一大進步,但其所使用的保溫材料的原材料屬有機化工材料,大部分來源于石油,生產制造能耗高,隨著油價和電價的飆升以及這種復合保溫體系的施工較為復雜,難免造成工程質量中的許多問題。因此,反思我國幾十年來建筑業的發展實踐、克服現有復合體系的不足、充分認識加氣混凝土單一墻體保溫體系在建筑節能中的作用和發揮其獨特的優勢是具有現實和長遠意義的。其優勢表現為:1)我國大部分加氣混凝土企業原材料主要是工業廢料粉煤灰。我國煤炭資源豐富,火電是主要發電方式,粉煤灰資源豐富,分布面廣。2)制造工業化程度高,產品質量有保證。3)施工簡單、工序少且效率高。4)在造價方面比外保溫復合體系有很大優勢。5)耐久性好,如在瑞
12、典,20世紀30年代就開始使用,已有70多年的歷史;原上海楊浦硅酸鹽制品廠麻毅同志考證的上海國際飯店內墻和福州大樓外墻,使用年限基本和瑞典同步,也長達70余年。6)產品可一材多用:既可以做成板材(用作外墻、隔墻、屋面甚至于樓板),又可做砌塊(用作外墻、內墻和隔墻),還可制造保溫材料(用作屋面、地面以及復合外墻,尤其是近年研發出的B03、B04級輕質制品,保溫特性更優化),最近又開發出的鋼結構防火板,使其應用的領域更加廣泛。筆者自2005年發表過以上觀點后陸續聽到各方面的意見和建議。本文就保溫和墻體合一的保溫體系作一些補充闡述。1、 在我國不同氣候區使用是否可行保溫和墻體合一的保溫體系能否在全國
13、使用取決于材料性能能否符合各地不同氣候區的節能標準。我國現行節能規范從建筑類型上分為“公共建筑”和“居住建筑”;按不同氣候區來分,目前已發布的規范有章可循的分作4個地區:即夏熱冬冷地區、夏熱冬暖地區、寒冷地區和嚴寒地區(又分A區和B區);從節能率來看,可分為節能50%和個別城市節能65%地區,詳見表13。可以看出,外墻傳熱系數K要求最高的是嚴寒地區A類公共建筑和居住建筑,要求K 0.4 W/(m2.K);要求最低的是夏熱冬暖地區的居住建筑,當熱惰性指標D 3.0時,其傳熱系數K僅要求為2.0 W/(m2.K)。當然這些數值也不是絕對的,最終以單位面積耗能量判定,各部位可以調整,但為便于對問題的
14、探討,暫以此指標為界定值。由此再來審視各類級別、各種厚度的加氣混凝土砌塊墻的熱工指標,能否滿足上述要求。加氣混凝土砌塊墻的級別可分為B04B07級;墻厚可分為200500 mm,級別與厚度疊加品種繁多選擇余地多樣;墻體砌筑灰縫厚度可分為15 mm和3 mm共2種,詳見表45。可以看出,墻厚40 0mm,灰縫3 mm的B04級砌塊,其傳熱系數K就能達到0.37 W/(m2.K),滿足嚴寒地區公共建筑和居居住建筑的傳熱系數指標(0.4 W/(m2.K))要求,此種砌塊應用在其它地區當然更沒有問題。 表1 公共建筑外墻傳熱系數K W/(m2.K)體形系數 0.3 0.3且 0.4 0.4夏熱冬冷地區
15、 1.0夏熱冬暖地區 1.5寒冷地區 0.6 0.5嚴寒地區B 0.5 0.45嚴寒地區A 0.45 0.40北京地區乙類 0.6 0.50 0.45甲類 0.8注:摘自公共建筑節能設計標準(GB 50189-2005)表-1;公共建筑節能設計標準(DBJ 01-621-2005)表-2和。 表2 居住建筑外墻傳熱系數K W/(m2.K)體形系數 0.3 0.3夏熱冬冷地區K 1.5 D 3.0K1.0 D 2.5夏熱冬暖地區K2.0 D3.0K1.0 D2.5K1.5 D3.0K0.7嚴寒及寒冷地區0.521.100.40.8注:1)摘自民用建筑節能設計標準(采暖居住建筑部分)(JGJ 26
16、-95);夏熱冬冷地區居住建筑節能設計標準(JGJ 134-2001);夏熱冬暖地區居住建筑節能設計標準(JGJ 75-2001)。2)本標準為節能50%指標。表3 北京居住建筑節能 設計標準(外墻部分)傳熱系數K W/(m2.K)4層及以上建筑0.6(外保溫)特殊情況下采用內保溫主體部位傳熱系數K0.33層及以下建筑0.45(外保溫)不得采用內保溫注:1)摘自居住節能設計標準(DBJ 11-6002-2006)中第3條和表。2)本標準為節能65%指標。表4 加氣混凝土砌塊墻厚級別及平均傳熱系數K W/(m2.K) 墻厚/mm B04級B05級B06級2000.670.782500.580.7
17、63000.593500.460.604000.420.484500.340.450.505000.310.38注:1)砌塊灰縫不大于15 mm。2)灰縫修正系數為1.25。表5 加氣混凝土砌塊墻厚級別及平均傳熱系數K W/(m2.K)墻厚/mmB04級B05級B06級2000.590.680.762500.510.583000.450.573500.464000.370.420.474500.280.345000.250.31注:1)砌塊灰縫不大于3 mm。2)灰縫修正系數為1.0。 由以上分析可知,加氣混凝土墻作為單一保溫墻體能滿足當前全國各個地區的節能標準,那怕是最寒冷的嚴寒地區A的各類
18、建筑,但墻厚應為400 mm。按傳統而言,在我國嚴寒地區墻厚通常為370 mm或490 mm,但當時是小磚砌筑,在技術上沒有問題。而加氣混凝土砌塊體積大、份量重是否會給施工帶來困難?這一問題也不難解決,砌筑時可分2層砌筑,如250 mm+150 mm或200 mm+200 mm,或用簡單的機具吊裝,在技術上也應該沒有問題。與保溫復合墻比,其缺點是,相對減薄墻厚、減少建筑面積、增大使用面積等方面有優勢,而從單方造價來看,單一墻體占絕對優勢。如何取舍還需要分析:損失使用面積(或加大建筑面積)合算?還是降低造價合算?這取決于投資者的決策。當然在技術上還有別的選擇,即將加氣混凝土墻也可做成復合墻,尤其
19、做內復合墻,優點十分明顯,當然也可做成夾心保溫墻。2、 在經濟上是否可行筆者對全國建筑造價材料價格不太了解,僅就北京地區做過分析。將北京地區經常使用的4種墻體與保溫板(EPS板)復合后的墻厚、熱工性能和造價3方面與密度為B04、B05、B06級和砌筑灰縫不大于15 mm和不大于3 mm的不同加氣混凝土墻厚作比較,發現同樣墻厚、同樣熱工性能的單一墻體材料較為突出的是B05、B06級產品比復合墻體材料的造價要低45%左右,如當輕骨料混凝土和混凝土空心砌塊復合墻的墻體厚度分別為275和288 mm、傳熱系數K 0.58 W/(m2.K)時,造價分別為142.90和147.59元/m2(其中防護層做法
20、已包括人工)。同樣傳熱系數K 0.58 W/(m2.K),采用B05、B06級產品灰縫不大于3 mm,墻厚為325 mm的單一墻體造價分別為65.90和75.90元/m2,如采用B04級產品,灰縫不大于3 mm,墻厚為225 mm和275 mm的單一墻體,造價分別為75.90和89.10元/m2(其中材料費雖不包含人工費,但已包括砌筑砂漿和內外墻抹灰材料),詳見表6。故在寒冷地區,如節能65%的北京地區,單一節能墻體在經濟上占有絕對優勢。表6 北京地區4種復合外保溫墻體與加氣混凝土單一墻體材性和價格比較墻厚/mm墻體價格EPS保溫板厚度/mm保溫層價格保溫墻體總厚度/mm墻體傳熱系數K/(W/
21、(m2.K)墻體總價格/(元/m2)單方價格/(元/m3)每m2單價/(元/m2)保溫層單價/(元/m2)防護層單價/(元/m2)每m2單價/(元/m2)KP1多孔磚24016539.006021.07899.03200.58138.00輕骨料混凝土空心砌塊19022048.006622.778100.72750.58148.70混凝土空心砌塊19023947.807024.578102.52850.57150.30混凝土墻體180236.7543.007024.578102.52700.59145.50加氣混凝土砌塊(B05、B06)(灰縫不大于15 mm)25020050.002750.7
22、6(B06)64.1030061.003250.59(B05)75.1040080.004250.48(B05)94.10加氣混凝土砌塊(B05、B06)(灰縫不大于3 mm)20020050.002250.68(B05)0.76(B06)62.7025061.002750.58(B05)71.9030080.003250.57(B06)82.70加氣混凝土砌塊(B04)(灰縫不大于15mm,.灰縫不大于3mm)20030060.00225(15縫)225(3縫)0.67(15縫)0.59(3縫)74.1075.9025075.00275(15縫)275(3縫)0.58(15縫)0.51(3縫
23、)89.1090.9030091.00325(15縫)325(3縫)0.45(3縫)105.5106.90350105.26375(15縫)375(3縫)0.46(15縫)119.30121.16400120.00425(15縫)425(3縫)0.42(15縫)0.37(3縫)134.10135.90注:1)B04級加氣混凝土砌塊售價300元/m3,灰縫不大于3 mm砌筑粘結劑用量為6.8 kg/m2,合6.8元/m2(單價1000元/t),外墻干粉抹灰砂漿用量為10.8 kg/m2,合5.4元/m2 (單價500元/t),內墻粉刷石膏用量為9 kg/m2,合3.7元/m2(單價410元/t)
24、,總的配套砂漿合15.9元/m2。表中墻體總價格已包含砌筑砂漿和內外墻抹灰。墻材價格摘自北京工程造價信息2008年2月刊。2)加氣砌塊灰縫不大于15 mm砌筑砂漿合5元/m2,加內外抹灰共14.1元/m2,表中墻體總價格已包含砌筑砂漿和內外墻抹灰。3)其它墻體外保溫做法價格不包括內墻抹灰和砌體砌筑砂漿。4)加氣砌塊灰縫不大于3 mm的墻體熱工性能與加氣外墻板相同。5)熱工數據摘自公共建筑節能構造(嚴寒和寒冷地區)(06J908-1),公共建筑節能構造(夏熱冬冷和夏熱冬暖地區)(06J908-2),蒸壓加氣混凝土砌塊建筑構造(03J104)。6)本造價是去年數據隨著經濟危機的發生,保溫材料價格有
25、所下降,但對總造價而言并不明顯。3、 在技術上是否可行3.1 “熱橋”問題“熱橋”是保溫體系普遍存在的問題,關鍵是什么樣的“熱橋”不允許?會產生結露的熱橋是不允許的。與復合墻體相比,加氣混凝土單一墻體的某些部位不存在“熱橋”問題,如女兒墻、窗戶外側周邊墻。當然,在梁、柱、構造柱等處,由于其外表面因2種不同材料處于同一表面所產生的“熱橋”問題同樣存在,若產生結露,也要解決。1)對于會產生結露的地區,一般是粘貼聚苯乙稀泡沫保溫板,為防止界面處開裂,還需要特殊處理(如玻纖網格布聚合物水泥砂漿),比較麻煩。當前國外的處理方法是在該部位采用復合材料,外部為低密度加氣混凝土薄板,內貼聚苯乙稀保溫板的配件,
26、這樣該部位的外表與墻體為同一材料。目前我國的生產水平已有可能生產這種配件,如將04級的產品(目前有些工廠已能生產B03級產品)切割成厚度為3 mm的薄片,工廠就可以專門制作解決“熱橋”部位的復合外保溫配件。2)加氣混凝土的灰縫“熱橋”問題應該注意。因為其熱工性能好,所以墻身可以比較薄,但帶來的問題是灰縫距離短,如用普通砂漿灰縫厚度,在該部位易產生“熱橋”,解決方法有3種:一是采用具有一定保溫性能的砌筑砂漿,如過去現代公司生產的AM1砌筑砂漿;二是采用密縫粘結砂漿,灰縫不大于3 mm,但前提是砌塊尺寸必須精確;三是將墻加厚,但這要做各方面的分析。3)還有的“熱橋”部位是出挑構件(如陽臺的樓板、擋
27、板、分戶墻板以及門頭的雨罩、空調機擱板等),這也是保溫體系的普遍問題。這一問題應從建筑設計的根本抓起,如有些可有可無的出挑構件能否取消?另外能否將構件與墻的面接觸改成點接觸以減少“熱橋”面積?再一個方法是根據加氣混凝土制品本身就是保溫構件的特點,出挑的陽臺樓板、擋板、雨罩等應該可以全部用加氣混凝土板材解決。根據國外一些先進經驗,把出挑部分作成一相對獨立于建筑物之外,但又與主體結構拉結的構筑物,與主體結構“斷橋”,如陽臺、雨罩等,這不能不認為是一種較好的設計理念。3.2 墻厚問題從表16分析,加氣混凝土墻作為單一保溫節能墻體,在寒冷地區及其以南地區,在滿足當地熱工性能條件下,比復合墻體有優勢,在
28、嚴寒地區也有相當優勢,但A區,其傳熱系數K要達到0.4 W/(m2.K),如采用B04級加氣混凝土單一材料則厚度要達到400 mm。而復合墻體最厚為340 mm(KP1多孔磚),最薄的僅為295 mm(混凝土墻),具體見表7。雖然單一材料在造價方面占優勢,但至今還沒有對嚴寒地區墻厚的限制規定。這里涉及的因素較多,有技術問題、經濟問題以及施工等問題,只有通過一段實踐以后才能做出定論。從理論上講,根據嚴寒地區的傳統習慣,墻厚在400 mm左右應該可以接受(據說某些嚴寒地區墻厚可放寬到不大于500 mm),這樣,灰縫不大于15 mm的 B05級產品其傳熱系數K就能達到0.38 W/(m2.K),灰縫
29、不大于15 mm和不大于3 mm的B04級產品分別就能達到0.310.25 W/(m2.K)。如果一定要減薄,如前所述,加氣混凝土也能做復合墻,尤其做內復合,不僅可以減薄墻厚,提高熱工性能,還可以克服大部分“熱橋”。如果墻體本身是保溫材料,有些傳統墻體材料的內外保溫復合體系存在的“熱橋”問題就不存在。內復合不但可以克服其它體系的各種缺點(如部分出挑構件以及灰縫的“熱橋”),還可以帶來其它的優點,如采用內復合后,在建筑外立面可以自由做各種附墻裝飾(如線條、柱式、窗套、飾面磚等)且造價比外復合低得多,施工也簡單得多,這些問題本人想再撰文論述。表7 復合墻厚與平均傳熱系數關系EPS板厚/mm墻總厚/
30、mm平均傳熱系數K/(W/(m2.K)190厚混凝土空心砌塊952850.441103000.39240厚KP1多孔磚903300.431003400.39180厚混凝土墻1002800.431152950.38190厚輕集料混凝土空心砌塊902800.451052950.39注:1)摘自國標圖公共建筑節能構造(嚴寒及寒冷地區)(06J908-1)。2)墻厚未包括抹灰。至于在南方地區的應用優勢,在此不再作贅述,它可以以最薄的墻身滿足該地區的熱工性能。在南方地區主要是解決隔熱問題,雖然加氣混凝土既有良好的保溫性能又有良好的隔熱性能,但同時滿足傳熱系數K和熱惰性指標D的要求是必要條件,因此在應用時
31、,需要對加氣混凝土的密度作適當的調整。當然在南方地區除對圍護結構要充分滿足其熱工性能外,還得在設計中考慮其它問題,如窗墻比、遮陽和通風等,這些也是十分重要的。3.3 墻面裂縫問題這一問題討論已久,已有不少文章見諸報端,綜合來看引起開裂的原因有以下方面:1)產品質量:如收縮和強度,根據東北建筑設計研究院馮堉生等同志的研究,粉煤灰制品自出釜含水率40%到平衡含水率5%,其收縮值僅為0.12 mm/m,經計算制品拉應力E0.12×10-3×1.75×1042.1 kg/cm2(式中,為制品拉應力,為制品變形值,E為制品彈性模量),而制品抗拉強度為2.5 kg/cm2(隨
32、著生產技術的發展有些產品均高于此值),不會由于收縮使制品拉裂,除非是不合格產品。尤其在應用技術規范上將上房含水率作了限制,這就更減小了由材性收縮引起的墻體開裂的風險。2)建筑構造失當:如薄弱部位沒有加強(如窗口下部、墻體角部)、2種不同材料的界面未作處理、墻身偏高過長以及結構變形對墻身的影響等。3)施工工藝:如上房含水率偏高、砌筑灰縫不夠飽滿(尤其是豎縫)、抹灰未按規程順序及成品缺乏養護等。4)抹灰材料和砌筑砂漿、界面處理和缺損填補等所用材料的材性與加氣混凝土材性不太相容等。經過幾十年的研究,加氣混凝土的應用技術幾乎都有章可循。如北京建材院生產的外墻干粉料砂漿,其強度控制在4.07.0 MPa
33、,壓折比不大于3.0,彈性模量為1 6002 000 N/mm2,與加氣混凝土強度為2.04.0 MPa,干燥收縮值為不大于5×10-4相匹配,且這種砂漿具有較好的保水性(80%),符合加氣混凝土的性能。在軟件方面,相關標準、規程、圖集均已陸續出版或正在報批、修訂,已出版的有砌塊標準、砌塊國家標準圖以及公共建筑國家標準圖。各種配套材料和零部件有不少已投入工業化生產,如內外墻抹灰材料、錨固件、施工工具等都已投入市場。設計施工只要按規程、圖集進行,按加氣混凝土特性選用配套材料,墻體開裂是不難解決的。當前的問題是一旦出現墻面裂縫就不加分析,籠統地歸罪于材料產品本身,這不是科學的態度,重要的
34、是加以分析,從實踐來看,近年來這些問題都在逐漸克服。3.4 嚴寒地區應用問題加氣混凝土的發展在我國寒冷及嚴寒地區發展的較早,如沈陽、長春、哈爾濱和齊齊哈爾等城市。但隨著時間的推移,逐漸形成今天南盛北衰的局面,其主要原因之一是在發展材料生產技術的同時,忽視了對材料應用技術的研究。嚴寒地區較突出的問題是凍害,20世紀80年代筆者曾對東北地區進行過考察,建筑某些部位的破壞比較突出,如窗坎墻、檐口、凸出于外墻的裝飾線腳、面磚等受凍害影響較大,但在同樣處于嚴寒地區的北歐,筆者在考察中并沒有見到這種情況,同樣在日本北海道,此種材料應用廣泛,主要是兩個問題:一是構造不合理;二是構配件不配套,產品本身抗凍應該
35、沒有問題。就加氣材性而言,其飽水時抗凍性能良好。從最近北京現代公司開發的B04級產品的檢測報告來看,強度為2.2 MPa,干密度為417 kg/m3的產品經抗凍試驗,其質量損失僅為2%(標準值為5%),凍融后強度為1.9 MPa(標準值為不小于1.6 MPa),證明了它是較好的抗凍產品,存在的問題是這一產品受局部凍融易破壞。20世紀80年代,在我國寒冷及嚴寒地區對這一問題可能認識不足,如當時在東北地區,窗檻墻沒有單框雙玻或三玻窗,大部分采用兩層單玻木窗,中間留出較大空隙,加之當時采暖制度大部分為間歇采暖,窗戶玻璃上結的露水向兩層單玻窗之間的空隙流淌,居民在其間放置鋸末或毛巾,因無防水措施,窗臺
36、和窗坎墻受局部凍融嚴重凍壞。同時灰縫“熱橋”也相當嚴重(當然有些產品質量也太差),有些采用加氣混凝土板出挑的檐口因無滴水構造破壞很嚴重,這些部分主要發生在春季,白天化,晚上凍。當然還有一些加氣混凝土應用中的普遍問題,如抹灰問題、門窗及物件固定問題等。以上這些問題從今天技術發展的水平上來看都不應該是發展這一產品的障礙,不會影響在這些地區發展單一墻體節能體系。當然加氣混凝土制品的應用除地區概念外,與建筑結構體系和商業經濟觀都有關系,如有些南方沿海地區地耐力差,但高層多,且大部分為框架結構,為減輕建筑自重用加氣混凝土作填充墻是較佳的選擇。現在不少多層和低層民居也用框架,底層商用,上層居住,這也是南方加氣混凝土的發展比北方迅速的原因之一。3.5 強度問題為提高單一墻體的熱工性能,減薄墻厚,在北方地區發展低密度加氣混凝土制品是大勢所趨。 目前北京B04級產品已能規模化生產,B03級產品也已開發成功。去年北京建材研究院修建了一座33 956 m2,高18 m的辦公樓,外墻采用B04級產品,經檢測該產品干密度為425 kg/m3,強度大于2.0 MPa,導熱系數為0.09 W/(m.K),指標均高于蒸氣加氣混凝土砌塊(GB 11968-2006)中的規定。此建筑墻厚為25 0mm,經計算其傳熱系數K=0.605 W/(m2.K),滿足北京公共建筑甲
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 關于黃岡的七下數學試卷
- 貨品分析培訓課件圖片
- 肥城中考數學試卷
- 肛腸五項技術課件
- 燈塔市期末考試數學試卷
- 浮山中學數學試卷
- 高級中學期末數學試卷
- 2025年06月浙江溫州市蒼南縣衛生健康系統面向社會招聘120編外輔助人員2人筆試歷年專業考點(難、易錯點)附帶答案詳解
- 2025年01月2025安徽池州市人民醫院勞務派遣辦公室文員招聘1人筆試歷年專業考點(難、易錯點)附帶答案詳解
- 銷售技能培訓課件分類
- 2023年本科招生考試
- 碳捕集、利用與封存技術課件
- 碳達峰和“碳中和”環境知識科普宣傳PPT教學課件
- 中文版b4a新手指南-第14-15章語言畫圖
- 新入職護士培訓考試試題及答案
- 《消防安全技術實務》課本完整版
- 公路工程標準施工監理招標文件(2018年版)
- 北師大版七年級數學下冊 與信息技術相融合的數學教學案例 教案
- 鈍針穿刺法臨床應用護理
- 精品中文版b4a新手指南第4章開發環境
- 光纜線路的故障分析及障礙搶修
評論
0/150
提交評論