




已閱讀5頁,還剩1頁未讀, 繼續免費閱讀
版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
1. stool handling, collection, transport regulations and management practices1.1 stool disposal regulations1.1.1 General provisions stool handling requirements:(a) without the safe disposal of faeces it can not be directly used as agricultural fertilizer. By fecal harmless treatment should be consistent with the relevant provisions of the current national stool sanitary standards (GB7959) of.(b) should complete monitoring, testing equipment and systems, the treated manure should be regularly tested, does not meet the criteria, should be re-treated until it meets the standards.(c) excreta disposal should be carried out in a closed state, not bare stool odor non-proliferation.(d) the residue generated in the process of the stool, and concentrated or dehydrated manure sludge, should be harmless treatment; prolapse after concentrated manure should be harmless or pre-treated sewage into the pipe network, centralized processing by the sewage treatment plant.(e) clear Amoy fecal residue should be closed transport into the stool sample processing station centralized processing, non-random process.(f) faecal sewage treatment before discharge into surface water, water quality should comply with their emissions on existing national regulations, Integrated Wastewater Discharge Standard (GB8978) .(g) Hospital manure wastewater treatment, should follow the medical institutions water pollutant discharge standards (GB18466-2005) existing national provisions.1.1.2 excreta disposal station shall comply with the general requirements of 1.1.1, it must also meet the following requirements: (a) stop the feces directly through the septic tank should be discharged into septic tanks, into the fecal-oral and fecal-slot should be no fecal residue. After unloading manure, should be Gaiyan fecal-oral, fecal groove.The residue (b) should be pretreated collected in a closed container, and sound processing, can not bare stacking. (c) by the sludge digestion process should be good stability, no odor, no breeding of mosquitoes.(d) treatment station environment should be clean, with a greenbelt and other protective equipment, almost no mosquitoes, no stench.1.1.3 Mixed composted feces and garbage, should comply with the national stool sanitary standards (GB7959) in high-temperature composting sanitation standards.1.1.4 processed manure septic tank effluent, shall comply with the general requirements 1.1.1, it must also meet the following requirements:(a) The septic tank should be sealed good, manholes, fecal suction mouth should be rain-proof, odor from leaking devices should be no leakage, no overflow, and there is fire, explosion facilities(b) the residence time of fecal sewage in septic tanks, manure should be based on how much water to 12 to 24 hours. For hospitals using septic tanks, manure wastewater pretreatment, the residence time should not be less than 36 hours.(c) The septic tank should be cleaned regularly, but the bottom 20% of the amount of sludge should be retained.(d) venues around the septic tank should be kept clean and tidy, almost no mosquitoes, no stench.1.1.5 processed manure storage pits shall comply with 1.1.1 of common requirements, but also meet the following requirements:(a) proper storage pits surrounding greenbelt and other isolation protection facilities.(b) storage pits should be sealed, no leakage, odor does not spill, and there is fire, explosion facilities.(c) the grounds and surrounding environment should be clean, almost no mosquitoes, no stench.1.2 feces collection1.2.1 collect feces residential areas, offices, schools, factories, businesses, service industries, etc. shall meet the following requirements:(a) shall be (including residential property area), private houses and other construction time and the amount of the population live, regular septic tanks Qingtao according to residential areas.(b) departments and units, schools, factories, businesses, service industries and other services should be based on the amount of population, regular septic tanks Qingtao ensure 1-2 times a year, can increase the number Qingtao according to the actual situation, in order to ensure that there overflowing.(c) underground septic tank should be no seepage, no leakage, no overflow, and a fire, explosion and other safety facilities.1.2.2 toilets stool Qingtao operations should meet the following requirements:(a) should be removed regularly toilets reservoir (of) septic tanks manure, slurry does not overflow.(b) the collection and transport containers should be sealed, and no dripping. When the stool collection, transportation, containers should be capped tightly closed.(c) should be kept clean job site, no spill feces. After Qingtao job should Gaiyan fecal-oral, and timely cleaning the site and Qingtao tools.1.2.3 driving, all kinds of ships moored in the waters of Dongguan urban sewage from ships (including fecal sewage) treatment, according to Peoples Republic of China Water Pollution Prevention Law, Peoples Republic of China Prevention of Pollution from Ships inland water environment regulations and the relevant provisions of the relevant laws and regulations, the implementation of regulations.1.2.4 Public toilet stool by the territorial town (street) Utilities Service Center organization Qingtao, residential areas, units, etc. by the property unit or management unit is responsible Qingtao also be commissioned on behalf of the relevant market enterprises paid Qingtao.1.3 stool transport1.3.1 stool transit should meet the following requirements:(a) fecal RTS (courses, marinas) facilities should be in good condition, clean and tidy. Transport of fecal sewage should be stored in airtight storage pits. Storage pits should comply with anti-leakage, anti-odor and flies proliferation requirements, and set fire and explosion safety.(b) storage pits inside the stool should be transported, can not spill.(c) transport manure pipe should be intact, smooth, valve should be tight, no damage, drip.(d) In transit operations, not to pollute the water and fecal job site. Rinse the job site should be appropriately treated sewage discharged into the sewage pipe network or collection tank may not be directly discharged into nearby water bodies.(e) unloading manure caution should not be spilled in the stool around the fecal-oral dumping ground. End of the job, should be cleaned unload the fecal-oral and job site.(f) faecal RTS (courses, marinas) should be prepared in addition to the four evils and deodorant action. In the visible range, the flies no more than 3 / times, no maggots, no stench.1.3.2 Vehicle Transportation stool should meet the following requirements:(a) The vehicle shall be in good condition, clean, the body no traces of fecal contamination.(b) loading the container should be sealed good. Put manure valve, fecal-oral intake should be tight, and there are anti-drip measures; during transport should be no leakage, spills, vehicle left the site should be cleaned.(c) The loading should be adequate, no spills; loading manure, should be promptly unloaded clear, can not long remain in the stool tank car.(d) Promptly remove stool designated place, one shall be arbitrarily emissions.(e) transport operations, vehicles should be cleaned and auxiliary facilities shall not leave traces of fecal contamination.1.3.3 shipping feces should meet the following requirements:(a) The ship should be intact, clean and tidy. Proper isolation between devices and security facilities manure storage tanks and studio, living cabin.(b) manure storage tanks should be sealed, leak-proof performance good.(c) shall not exceed the approved loading loading ships. Transit, manure can not be poured outside.(d) shall comply with the requirements of the sealed container loading and unloading facilities; when loading and unloading operations, manure can not be compromised.(e) stool storage tanks should be regularly sprayed in addition to the four evils of drugs, do not fly no maggots.2. New technology applied to fecal residue collection, transportation management system In fecal residue collection and transportation system management is widely used new technology is an important method to improve management efficiency. The development of technology to achieve a diverse management tools, s
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 張掖市鄉村產業振興的優化路徑研究
- Rab32家族蛋白調控自噬體組分循環的機制研究
- 基于PSO-LightGBM和Stacking融合算法的信貸違約行為預測研究
- 具身認知視域下的高中歷史項目化學習研究
- 關于虛擬紐結多項式不變量的研究
- 擠壓態Ti-45Al-(Nb,Mo,B)合金顯微組織及葉片真空等溫鍛造技術研究
- 建筑功能分區視角下城市熱環境影響因素研究-以黃石市沿磁湖區域為例
- 基于導模晶格共振的葡萄糖生物傳感器的研究
- 明清浙江徽商園林調查與研究
- 幾種金基納米材料的制備及其癌癥診療研究
- 浙江省杭州市北斗聯盟2024-2025學年高一下學期4月期中聯考地理試卷(含答案)
- 核醫學講課比賽技巧與策略
- 2025年貴州六盤水市燃氣集團六盤水燃氣有限公司招聘筆試參考題庫含答案解析
- 妊娠期子宮蛻膜息肉診治中國專家共識(2024年版)解讀課件
- 病毒性心肌炎病例分析與治療
- 幼兒園教育懲戒的邊界與藝術
- 交通安全與一氧化碳安全教育
- 2025年出版:全球市場工程機械多路換向閥總體規模、主要生產商、主要地區、產品和應用細分調研報告
- 桶裝飲用水質量檢查報告
- 寵物托運協議合同書
- 《2024 3610-T-339 可配置汽車信息娛樂服務 第 2 部分:要求》知識培訓
評論
0/150
提交評論