Flexi設備知識培訓_第1頁
Flexi設備知識培訓_第2頁
Flexi設備知識培訓_第3頁
Flexi設備知識培訓_第4頁
Flexi設備知識培訓_第5頁
已閱讀5頁,還剩64頁未讀 繼續免費閱讀

下載本文檔

版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領

文檔簡介

Flexi BSC結構與功能 1 TCSM 功能和結構 2 Flexi EDGE BTS介紹 3 1 2nd BSC generation Large Capacity SW up to 256 TRX (S6) with 2 racks 660 TRXs with 1-cabinet BSC3i 660 configuration (S10.5) 1000 TRX with 1-cabinet and up to 2000 TRXs with 2 cabinets by BSC3i 1000/2000 (S12 & S13) 3000 TRX with 1-cabinet by Flexi BSC (BSC3i Flexi) (S14) Complete solution for future CS and PS traffic handling capacity requirements with IP connectivity High Capacity BSC along with smooth upgrade path (S8) Capacity increase up to 512 TRX with 2 racks 1991 1995 1999 2002 BSC3i BSC2i BSCE First BSC generation Up to 128 TRX with 2 high racks BSC2 2007 2009 第一代產品 第二代產品 第三代產品 2 連接能力 / TRXs 電路域 / 話音 分組域 / 數據 傳輸能力 - E1/T1 - STM-1/OC-3 - IP Transcoding / channels 660 TRXs 4 000 Erl 6 140 x 16 kbit/s CHs 256 E1 / T1 lines - 4 GE links for Gb, O&M, Lb, Sigtran, DFCA 960 channels with TCSM2 參數 BSC3i 660 3 000 TRXs 18 000 Erl 30 720 x 16 kbit/s CHs 800 E1 / T1 lines 16 STM-1/OC-3 12 GE links including also Abis and A i/f 34 000 channels with TCSM3is Flexi BSC (BSC3i3000) 2 000 TRXs 12 000 Erl 25 600 x 16 kbit/s CHs 800 E1 / T1 lines 16 STM-1/OC-3 8 GE links for Gb, O&M, Lb, Sigtran, DFCA 11 520 channels with TCSM3i BSC3i 1000/2000 Flexi BSC 家族 3 Flexi BSC eBSC BSC3i2000 機架尺寸 (高 *寬 *深) 2000mm*900mm*600mm 2000mm*600mm*450mm 2*(2000mm*900mm*600mm) 最多載頻數 TRX 3000 2000 2000 最多小區數 3000 1000 2000 最多基站數 Sites 3000 500 2000 PCM Lines 800 E1 288 E1 800 E1 SDH/Sonet Connectivity 16 + 16* STM-1/OC-3 8 + 8* STM-1/OC-3 16 + 16* STM-1/OC-3 IP connectivity 12 + 12* Giga-Ethernet 4 + 4* Giga-Ethernet (RG20) 12 + 12* Giga-Ethernet (改造后) Erlang 18000 10000 12000 E-GPRS Channels (16 Kb/s) 30720 8500 25600 每載頻功耗(瓦) 0.7 W (正常情況) 1.3 W (正常情況) 30720 Abis channels / Flexi PCU2-E PIU BTS Objects TRX Objects Abis Channels Up to 30 x 384 Up to 30 x 1,024 Up to 30 x 1,024 PCU2-E Capacity 21 OMU( Operation and Maintenance Unit)是 BSC與高一級網絡管理系統和用戶之間的一個接口,它可以進行 BSC本地操作和維護。 OMU從 BSC接收故障指示后,向用戶提供本地告警打印輸出或向網管系統發送故障指示。系統故障時, OMU在 BSC內自動激活適當的恢復和診斷流程。 提供用于本地操作的 I/O接口 OMU主要執行下述功能 : 測量報告管理 BSC維護管理 BSC系統配置和狀態管理 BSS系統管理 LAN 拓撲結構管理 OMU OMU Plug-in units CP816-AC AS7-D HWAT-B SERO-B PSC6-AB Mass memory adapter: DCAR1-A 22 提供 USB接口 USB存儲設備提供可靠的軟件和數據庫備份 可支持 4GB的移動設備 包含 2個硬盤( HSD07 ): 互為鏡像保持高的安全性。 可以不中斷業務進行升級和改變 每個硬盤的容量是 73 GB 指示燈 : 綠色 正常 紅色 故障 Hard disk AMC front panel (HDSAM-A) Red - out of Service green Power good Blue Hot Swap amber hard disk drve activity 23 Flexi BSC cabinet LANU GSW2KB GTIC CLOC ETC ETC ETC LANU LANU GTIC GSWB CLOC ETC ETC GTIC GSWB CLOC 24 通過 BSC傳送業務; 需要連接信令單元和內部數據傳輸單元 背板上通過 ET1提供 8Mbit/s連接; 前板通過 ETS2/ETIP提供 2 HotLinks/SW256連接; 負責 BSC的子復用功能。 GSW2KB的特性包括: 2048條 real PCM 16384條 virtual PCM 基于 8kbit/s的水平交換 一個 GSW256B最多 65536個 8kbit/s信道 8個 SW256B Configuration includes 8 x SW256B plug-in units 25 時鐘單元 CLS在 BSC中的功能是接受上一級傳過來的外接時鐘參考,也向 BSC中的各個單元提供時鐘信號; 自身也能產生標準時鐘信號 收集各個單元的告警上傳至 OMU中。 ( CL3TG-UA)插板單元位于SGC1C-A插框中,通過交換能產生基本的時鐘信號,從接收到的ET或外部 FS中同步幀對齊信號。 具體的同步信號輸入包含連接面板上的 4個 ET和 2個外部輸入 FS。 CLS面板上共 3個燈: 1燈亮, 2M1; 2燈亮: 2M2 3: 2M4; 1&2: 2M3; 1&3: FS1; 2&3: FS2 2 x CL3TG units (2N redundancy) 26 LANU- 0 & 1 ETC 0-4 and GTIC 0-1 LANU單元包含 3個 ESB24插板,有兩個功能 : 第二槽道上的 ESB板連接各個計算機單元的 CPU板,提供以太網接口,并同時可以連接到網管端( CE交換機上),實現網管對 BSC的監管和操作; 它的三四槽道上的 ESB板,連接 BCSU上的 PCU板,并連接到SGSN端,實現 Gb over IP。 ESB24 單板共提供 24個端口 : - Port 1, 2, 23 和 24 在前面板 . - Port 3 到 22 在備板上 . 27 IP backbone BSC units 28 提供 BSC的外部連接線,包括 2M電路、 SDH和以太網,根據不同的插板實現。 每個 ETS2單板可容納 2根光纖。 FlexiBSC最大可包含 2*8個 ETS2并提供 16個外部接(光)口。 12個 EET口? ETS2和 ET16可以交替在GTIC框中使用。 ETIP和 ET16可以交替在GTIC框中使用。 0 - 16 x ETS2 units 0 - 16 x ETIP1-A units 0 - 16 x ET16 units 29 ETC 0-4 GTIC 0-1 ETC 0-4 and GTIC 0-1 提供 BSC的外部 PCM線連接。 每個 ET16 可提供 16條 PCMs (E1/T1) Flexi BSC 最大可容納 50個 ET16 提供 800個外部 PCMs (E1/T1)接口。 30 新的插板 : ETIP1-A for EET interface PCU2-E for Packet data PSC6-D for power supply in each ESB24-A for ethernet switch SWPRO-C for controlling GSWB 公用部分 : FTRB-A enhanced fan units CP816-A CPU for all computer units Bit based group switch for 2048 PCMs (GSW2KB) ET16 for E1/T1 interface ETS2 for STM-1 or OC-3 interface DCAR-A for mass memory LANU Ethernet Message Bus (EMB) MCMU 1 OMU Flexi BSC cabinet MCMU 0 BCSU 0 BCSU 1 BCSU 3 BCSU 5 LANU 0 BCSU 2 BCSU 4 BCSU 6 LANU 1 GTIC 1 GSWB 1 ETC 1 ETC 3 CLS 1 GTIC 0 GSWB 0 ETC 0 ETC 2 CLS 0 31 #TRX per BSC 1500 5011,000 1,0011,500 1,5012,000 2,0012,500 2,5013,000 #active BCSU 1 2 3 4 5 6 Max. #BTS / #BCF 500 1,000 1,500 2,000 2,500 3,000 Max. #logical PCU2-E 5 10 15 20 25 30 Max. #PS Abis chan16 5,120 10,240 15,360 20,480 25,600 30,720 Max. #RTSL 4,000 8,000 12,000 16,000 20,000 24,000 Max. #SS7 links 64 kbps 128 kbps 256 kbps 512 kbps 1024 kbps HSL (2M) Additionally Sigtran (SS7 over IP) 8 4 2 2 1 2 16 8 4 4 2 4 16 12 6 6 3 6 16 16 8 8 4 8 16 16 10 10 5 10 16 16 12 12 6 12 Max. #LAPD 992 1,984 2,976 3,968 4,960 5,952 #Transmission PCM (ET16) STM-1/OC-3 (ETS2) IP/PWE (ETIP1) 50 16 8 50 16 8 50 16 8 50 16 8 50 16 8 50 16 8 PDFU 0 PDFU-B PDFU 1 PDFU-B BCSU 3 BCSU 1 BCSU 5 BCSU 4 BCSU 2 BCSU 6 FTRB 1 FTRB 0 CLS 1 GSW2KB 1 OMU BCSU 0 MCMU 0 MCMU 1 GSW2KB 0 GTIC 1 GTIC 0 CLS 0 ETC 0 ETC 1 ETC 2 ETC 3 LANU 0 LANU 1 2000 x 900 x 600 cabinet FTRB 3 FTRB 2 1 3 5 4 6 2 32 Flexi BSC結構與功能 1 TCSM 功能和結構 2 Flexi EDGE BTS介紹 3 33 Up to 960 ETSI / 768 ANSI Ch Extension Step 120 ETSI / 95 ANSI Added unique features for superior voice quality such as Acoustic Echo Canceller and Noise Supression Third generation from 1995 from 2006 Second generation TCSM3i TCSM2E/A First generation Up to 450 ETSI Ch Extension Step 15 ETSI from 1992 BB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUBB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUBB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUBB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUBB20382EA1SMHWLK2MLK2MLK2MDB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15DB2MDX2MTRC15TRC15SM2M(or TRCU) TRCU TRCU TRCUTCSME Up to 11520 ETSI / 9120 ANSI Ch Extension Step 960 ETSI / 760 ANSI All TCSM2 features available Added enhanced pool options 34 容量大,結構緊湊,單機柜支持超過11 000 個業務信道 ( 384 A接口) 機柜數少,耗電量低,運維成本低 支持新的和 BSC3i 1000/2000的組合安裝方式,具有如下優勢 : 提供到 A接口和遠端 BSC的SDH/Sonet的光纖傳輸方式 幾個 BSC(包括本地和遠端的 BSC)可共享 TCSM3i 的容量 統一的電路池( All-in-one pool)簡化了對電路池配置的工作 35 T C S M 3 i s o f t w a r eS u p p o r t e d c o d e c s a n d f e a t u r e sS u p p o r t e d A - i n t e r f a c e p o o l s T y p e i n T C S M 3 i1 ( F R )3 ( D R )5 ( E F R & F R )7 ( E F R & D R )2 0 ( E F R & D R & D 1 4 4 )2 3 ( A M R )2 8 ( E F R & D R & A M R & D 1 4 4 )1 0 ( H S 2 )2 1 ( H S 2 & D 1 4 4 )1 3 ( H S 4 ) 2 2 ( H S 4 & D 1 4 4 )3 2 ( E F R & D R & A M R & H S 4 & D 1 4 4 )T 5 5 _ P X M X F R , H R , E F R , A M R , A E C , T F O , N S , 1 4 . 4 D , H S C S D , T T YGHINEW All-in-one Circuit Pools pool 28 and 32 TCSM3i does not support pool2 (8Kbit/s submultiplexing) T C S M 2 s o f t w a r eS u p p o r t e d c o d e c s a n d f e a t u r e sS u p p o r t e d A -i n t e r f a c e p o o l sT y p e i n T C S M 23 ( D R )7 ( E F R & D R )2 0 ( E F R & D R & D 1 4 4 )1 0 ( H S 2 )2 1 ( H S 2 & D 1 4 4 )1 3 ( H S 4 ) 2 2 ( H S 4 & D 1 4 4 )1 ( F R ) A5 ( E F R & F R ) AT D 2 _ P X M X H R , A E C , T F O , N S 2 ( H R ) BT D 3 _ P X M X A M R , A E C , N S 2 3 ( A M R ) F3 ( D R )7 ( E F R & D R )2 0 ( E F R & D R & D 1 4 4 )1 0 ( H S 2 )2 1 ( H S 2 & D 1 4 4 )1 3 ( H S 4 ) 2 2 ( H S 4 & D 1 4 4 )1 ( F R ) A5 ( E F R & F R ) AT D 6 _ P X M X A M R , A E C , T T Y 2 3 ( A M R ) FT D L _ P X M X F R , H R , E F R , A E C , N S , 1 4 . 4 D , H S C S DCDET D 1 _ P X M X F R , E F R , A E C , T F O , N S , 1 4 . 4 DT D 4 _ P X M X F R , H R , E F R , A E C , 1 4 . 4 D , H S C S D , T T YCDET D 5 _ P X M X F R , E F R , A E C , T F O , T T Y , 1 4 . 4 D36 Combi TCSM3i Stand-alone TCSM3i Fan tray Fan tray PDFU PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM ET ET ET CLS Air Guide Fan tray Fan tray PDFU PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM SET SET CLAB Air Guide FlexiBSC TCSM3i 37 Combi TCSM3i Stand-alone TCSM3i 相同點 同樣的機架 (M98 Mechanics, IC-209-B cabinet) 同樣的 TR3E完成編碼和子復用功能 每機柜最大的TCSMs單元數都為96. 同一機柜都可以服務于多個 BSC。 Fan tray Fan tray PDFU PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM ET ET ET CLS Air Guide Fan tray Fan tray PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM SET SET CLAB Air Guide 38 Combi TCSM3i Stand-alone TCSM3i Fan tray Fan tray PDFU PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM ET ET ET CLS Air Guide Fan tray Fan tray PDFU Fan tray Fan tray TCSM TCSM TCSM TCSM TCSM TCSM SET SET CLAB Air Guide 不同點 Combi TCSM3i 不需要配線框 . combi TCSM3i 使用CLAB而 Stand-alone使用 CL3TG. combi TCSM3i配置SBMUX和 ETS2, Stand-alone使用 ET16. TCSM框 Combi TCSM3i 不需要 ET16. 處理話務能力不同。 39 1 2 3 4 5 ETC0 ETC1 ETC2 6 7 8 9 10 11 12 13 14 15 16 1_2_3_4_5_6_7_8 17 18 19 20 21 22 23 24 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 Subrack Level 1 40 1 1 2 3 4 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 2 3 4 1,2,3,4,5,6,7,8 9,10,11,12,13,14,15,16 Only 1 BSC can be connected because of 1 Ater ET piu 2 BSCs can be connected because there are 2 ATER pius 5 6 7 8 5 ETC0 ETC1 ETC2 TC2C-0 TC2C-1 1_2_3_4_5_6_7_8 Indexes 6 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 0_1_2_3 7 4_5_6_7 8_9_10_11 12_13_14_15 8 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 Subrack Level 1 Subrack Level 2 41 9 10 11 12 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8 9,10,11,12,13,14,15,16 Only 1 BSC can be connected because of 1 Ater ET piu 2 BSCs can be connected because there are 2 ATER pius 13 14 15 16 ETC0 ETC1 ETC2 TC2C-2 TC2C-3 Indexes 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 9 10 11 12 13 14 15 16 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 Subrack Level 1 Subrack Level 4 42 17 18 19 20 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8 9,10,11,12,13,14,15,16 Only 1 BSC can be connected because of 1 Ater ET piu 2 BSCs can be connected because there are 2 ATER pius 21 22 23 24 ETC0 ETC1 ETC2 TC2C-4 TC2C-5 Indexes 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 0_1_2_3 4_5_6_7 8_9_10_11 12_13_14_15 1_2_3_4_5_6_7_8 17 18 19 20 21 22 23 24 1_2_3_4_5_6_7_8 1_2_3_4_5_6_7_8 Subrack Level 1 Subrack Level 5 43 Cabinet Head master TR3E/A Cabinet clock supervision ( O&M for CL3TG) Located at track 1 TR3E/A ( first TR3E/A is track 0 ) Cartridge master TR3E/A Ater interface ET16E/A supervision ( O&M) Located at track 0 TR3E/A in Cartridge and track 8 if 2nd Ater ET16 is used Master TR3E/A A interface ET16E/A supervision ( O&M) Located at track 0,4,8,12 TR3E/A in Cartridge Track 0 TR3E/A handles O&M for the A & Ater interface s ET16 (cartridge master) Normal TR3E/A TR3E/A in other locations 44 ETC2 1_2_3_4_5_6_7_8 ETC1 1_2_3_4_5_6_7_8 ETC0 1_2_3_4_5_6_7_8 TC2C-0 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17 TC2C-1 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17_18 CLS Only in track 1 of the TC2C-0 Cartridge Clock LAPD for O&M for clock supervision 45 ETC2 1_2_3_4_5_6_7_8 ETC1 1_2_3_4_5_6_7_8 ETC0 1_2_3_4_5_6_7_8 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 TC2C-0 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17 9,10,11,12,13,14,15,16 1,2,3,4,5,6,7,8 TC2C-1 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17_18 Ater-IF In track 0 of every TC2C Cartridge and track 8 if 2nd Ater ET16 is used ETLAPD of Ater-IF for ET supervision (O&M) 46 3 ETC2 7 1_2_3_4_5_6_7_8 2 ETC1 4 6 8 1_2_3_4_5_6_7_8 1 ETC0 5 1_2_3_4_5_6_7_8 1 2 3 4 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 TC2C-0 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17 9,10,11,12,13,14,15,16 5 6 7 8 1,2,3,4,5,6,7,8 TC2C-1 1_2_3_4_5_6_7_8_9_10_11_12_13_14_15_16_17_18 A-IF Track 0 TR3E/A handles O&M for the A&Ater IF ET16 (cartridge master) In track 0,4,8,12 of every TC2C Cartridge ETLAPD of A-IF for ET supervision (O&M) . .47 FlexiBSC對 TCSM3i的 ETS2的控制 PCM是 1714, 1715和 1722, 1723,這四條 PCM與 BCSU中 PCU的內部 PCM重復,必須刪除 BCSU-6數據,并將背板后的連線 拆除 使用 FlexiBSC與 TCSM3i Combine安裝后, FlexiBSC的實際容量為 2500TRX 現場到貨的 TC均為 Standalone配置,需現場將 TC升級至 Combine配置 Equipping CABLE FROM CABLE TO No FU Position FU Position Type Use Note BSCC_123 LANU 0 4.0B 13.1L BCSU 6 5.0B 16.1N CHG018 LAN remove BSCC_271 GSW2KB-A 0 1.0B 07.3L BCSU 6 5.0B 11.1Z CHF023 PCM remove BSCC_272 GSW2KB-A 0 1.0B 07.3C BCSU 6 5.0B 11.1R CHQ023 PCM remove BSCC_273 GSW2KB-A 0 1.0B 07.2U BCSU 6 5.0B 11.1J CHQ024 PCM remove BSCC_274 GSW2KB-A 0 1.0B 07.2M BCSU 6 5.0B 11.1A CHQ024 PCM remove BSCC_153 LANU 1 5.0B 13.1L BCSU 6 5.0B 17.1N CHG007 LAN remove BSCC_371 GSW2KB-A 1 2.0B 07.3L BCSU 6 5.0B 36.3Z CHF022 PCM remove BSCC_372 GSW2

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
  • 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
  • 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論