




版權(quán)說明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請進(jìn)行舉報(bào)或認(rèn)領(lǐng)
文檔簡介
1、目 錄一、工程概況. 1二、編制依據(jù). 1三、消防連廊模板支撐方案設(shè)計(jì) 1四、施工進(jìn)度計(jì)劃.7五、消防連廊施工方法.7六、主要施工材料和勞動(dòng)力用量情況.9七、質(zhì)量保證措施.9八、安全文明保證措施.11九、應(yīng)急救援預(yù)案.13十、型鋼懸挑腳手架計(jì)算書.18消防連廊專項(xiàng)施工方案一、工程概況1、工程概況XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
2、XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
3、XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX為了確保能夠優(yōu)質(zhì)、高效的完成消防連廊施工施工任務(wù)和本著“質(zhì)量更高、安全更重”的原則,特編制此方案。二、編制依據(jù)1、XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX 2、建筑施工扣
4、件式鋼管腳手架安全技術(shù)規(guī)范(JGJ130-2011); 3、鋼管腳手架扣件(GB15831-2006); 4、建筑物高處作業(yè)安全技術(shù)規(guī)范(JGJ 80-91);5、建筑施工手冊第四版6、建質(zhì)200987號(hào)關(guān)于印發(fā)危險(xiǎn)性較大的分部分項(xiàng)工程安全管理辦法的通知7、本企業(yè)同類工程施工經(jīng)驗(yàn)和技術(shù)資料三、消防連廊模板支撐方案設(shè)計(jì) 因本工程采用的是全鋼大模板和導(dǎo)軌式爬升腳手架,消防連廊無法一次性和現(xiàn)澆墻板同時(shí)澆筑,采用預(yù)留梁窩的施工方法對該部位進(jìn)行施工,梁窩采用泡沫板纏膠帶預(yù)留,預(yù)留梁窩的深度截面尺寸為滿足梁鋼筋0.4Lae錨固長度基礎(chǔ)上增加20cm預(yù)留,梁窩預(yù)留高度為梁截面高度基礎(chǔ)上增加10cm。1、根據(jù)
5、工程結(jié)構(gòu)形式、實(shí)際工程特點(diǎn),消防挑廊結(jié)構(gòu)重量較大,所以考慮采用工字鋼搭設(shè)挑出平臺(tái),然后在平臺(tái)上搭設(shè)滿堂鋼管腳手架用作挑廊腳手架。工字鋼梁挑出長度彈性較大,采用上斜拉方式保證平臺(tái)穩(wěn)定及剛度。2、挑廊腳手架以上搭設(shè)雙排鋼管腳手架,用作13層、16層結(jié)構(gòu)外墻體模板施工腳手架。3、按施工計(jì)劃,塔吊拆除比外挑架拆除時(shí)期早,考慮外挑架拆除時(shí)需分成小件逐根放下,所以平臺(tái)搭設(shè)工字鋼盡量采用較短尺寸,本工程拆除工字鋼時(shí)選用2臺(tái)起重功率為1噸的卷揚(yáng)機(jī)作為工字鋼、鋼管扣件垂直運(yùn)輸工具。因本工程消防連廊離建筑物構(gòu)件較近的地方基本都為懸挑構(gòu)件,懸挑構(gòu)件不作為承重構(gòu)件,所以工字鋼支撐點(diǎn)盡可能設(shè)置在非懸挑構(gòu)件上。4、鋼梁采
6、用20#工字鋼,-/、-/、-/軸線工字鋼長度為4m,里端1.2m錨固在已澆筑好的樓板上,外端2.8m作為排架及施工腳手架的支撐點(diǎn)。-/、-/、-/、-/軸線工字鋼長度為6m,里端2m錨固在已澆筑好的樓板上,外端4 m作為排架及施工腳手架的支撐點(diǎn)。-/-、-/-軸線工字鋼長度為9m,里端3.3m錨固在已澆筑好的樓板上,外端5.7作為排架及施工腳手架的支撐點(diǎn),因該兩處部位懸挑部分過大,在-/-, -/-軸各設(shè)一道12m的工字鋼對上述兩部位懸挑長度做支撐點(diǎn)以保證平臺(tái)穩(wěn)定及剛度。距離、軸線0.8m各設(shè)置一道工字鋼作為連梁兩端頭排架及施工腳手架的支撐點(diǎn)。5、工字鋼預(yù)埋吊環(huán)采用ø18鋼筋制作,
7、每根工字鋼上均設(shè)置4道預(yù)埋吊環(huán),鋼梁距離剪力墻邊20cm在現(xiàn)澆板上設(shè)置預(yù)埋第一道吊環(huán),距離剪力墻40cm在現(xiàn)澆板上設(shè)置第二道吊環(huán),里端距離工字鋼末端40cm設(shè)置第三道吊環(huán),距離工字鋼末端20cm設(shè)置第四道吊環(huán)(吊環(huán)預(yù)埋位置詳見平面布置圖)。每根鋼梁懸挑外端設(shè)置兩道18斜拉鋼絲繩用以保證平臺(tái)鋼度,-/-、-/-軸線9m工字鋼第一道鋼絲繩距離工字鋼懸挑外端1.2m設(shè)置,第二道鋼絲繩距離工字鋼懸挑外端2.8m設(shè)置,其余工字鋼第一道鋼絲繩距離工字鋼懸挑外端500mm,第二道鋼絲繩距離工字鋼懸挑外端1.8m,拉結(jié)鋼絲繩下端在工字鋼上滿焊100mm長25鋼筋頭作為鋼絲繩防滑裝置,上端為在剪力墻上預(yù)埋
8、48;32鋼套管用以穿鋼絲繩,鋼絲繩在上下兩端頭各設(shè)置4個(gè)18鋼絲繩夾連接鋼絲繩。6、工字鋼水平間距-/、-/、-/軸線為0.73m0.79m。-/-、-/-軸線工字鋼水平間距為1m,兩根12m長工字鋼距離軸剪力墻200mm設(shè)置。7、除-/-、-/-軸線其余軸線連廊模板支撐排架的立桿橫距(垂直連廊方向)1m,縱距(沿連廊方向)按工字鋼間距設(shè)置;排架底部(距工字鋼0.15m處)設(shè)置縱、橫向掃地桿,排架中部(距工字鋼1.05m處)設(shè)置縱、橫向連桿,排架頂部設(shè)置縱、橫向承重鋼管;排架立桿與剪力墻模板拉結(jié)牢固。橫桿一端與結(jié)構(gòu)剪力墻拉結(jié)作連墻桿,另一端與施工腳手架拉結(jié)作為施工腳手架的連墻桿。8、-/-、
9、-/-軸線連廊模板支撐排架的立桿橫距(垂直連廊方向)0.7m,縱距(沿連廊方向)按工字鋼間距設(shè)置;排架底部(距工字鋼0.15m處)設(shè)置縱、橫向掃地桿,排架中部(距工字鋼0.95m處)設(shè)置縱、橫向連桿,排架頂部設(shè)置縱、橫向承重鋼管;排架立桿與剪力墻模板拉結(jié)牢固。橫桿一端與結(jié)構(gòu)剪力墻拉結(jié)作連墻桿,另一端與施工腳手架拉結(jié)作為施工腳手架的連墻桿。9、連廊模板支撐排架橫向每間隔兩根工字鋼設(shè)置一道剪刀撐,縱向排架立桿設(shè)置連續(xù)剪刀撐。10、連廊內(nèi)外側(cè)施工腳手架橫距(垂直連廊方向)0.9m,縱距(沿連廊方向)按工字鋼間距設(shè)置;排架底部(距工字鋼0.15m處)設(shè)置縱、橫向掃地桿,中部橫桿根據(jù)模板排架橫桿間距搭設(shè)
10、(要求施工腳手架和模板排架橫桿為同一根完整的鋼管,且鋼管不得斷開和采用接頭扣件對接鋼管)。橫桿一端與結(jié)構(gòu)剪力墻拉結(jié)作連墻桿,另一端伸出施工腳手架的長度不得小于15cm。11、施工腳手架橫向每間隔兩根工字鋼設(shè)置一道剪刀撐,縱向立桿設(shè)置連續(xù)剪刀撐。腳手架防護(hù)欄桿高度為1.5m。腳手板采用滿鋪木跳板。施工腳手架外側(cè)鋼管的內(nèi)側(cè)滿掛阻燃型密目網(wǎng)。12、為了使模板排架及施工腳手架立桿與工字鋼鋼梁有可靠的定位連接措施,以確保上部架體的穩(wěn)定。故在工字鋼和槽鋼上焊接長度為150-200mm、直徑為25mm的鋼筋,將立桿套座其外。13、型鋼懸挑架搭設(shè)完畢后在掃地桿上滿鋪3000×250寬×50
11、mm厚木跳板做支撐架底部的的操作平臺(tái),木跳板鋪設(shè)后用鐵絲與鋼管鋼綁扎牢固。腳手板采用對接平鋪,接頭處設(shè)兩根橫向水平桿,腳手板端部探頭長度外伸為150mm。14、懸挑腳手架立面掃地桿往上1.2米高采用竹膠合板周圈封閉防護(hù),1.2往上至頂部周圈滿掛阻燃型密目網(wǎng)防護(hù)。懸挑腳手架側(cè)里面防護(hù)方法同正里面。15、-/-、-/-軸工字鋼距離墻3.19m處設(shè)置斜撐,斜撐采用18#槽鋼,支撐在工字鋼的下一樓層剪力墻上,無剪力墻的部位支撐設(shè)在框架梁上,框架梁設(shè)置埋件與槽鋼進(jìn)行焊接,框架梁上埋件采用植4根20cm長25鋼筋與鋼板焊接連接。在下層剪力墻上,斜撐槽鋼采用焊接與工字鋼連接和埋件連接。16、埋件采用300&
12、#215;200×10mm厚鋼板,距離鋼板4角兩邊長30mm處鉆30孔,用開孔器在剪力墻對應(yīng)鋼板的位置開4個(gè)30孔,剪力墻內(nèi)側(cè)同樣設(shè)置鋼板,兩塊鋼板采用M25螺栓相連接。 -/-、-/-、-/-軸線懸挑架搭設(shè)詳圖-/-、-/-軸線懸挑架搭設(shè)詳圖- 33 - / 35文檔可自由編輯打印 懸挑架搭設(shè)平面圖圖中所示紅色和青色部分為設(shè)計(jì)變更后增加的消防連廊, 消防連廊長度31400mm,寬度1400mm,消防連廊內(nèi)側(cè)與住宅樓陽臺(tái)相連接,消防連廊板厚度100mm,靠近陽臺(tái)一側(cè)欄板高度700mm,欄板板厚100mm。外側(cè)欄板高度1200mm,欄板板厚度120mm。1、懸挑腳手架立面掃地桿往上1.
13、2米高采用竹膠合板周圈封閉防護(hù),1.2往上至頂部周圈滿掛阻燃型密目網(wǎng)防護(hù)。懸挑腳手架側(cè)里面防護(hù)方法同正里面。2、掃地桿上滿鋪3000×250寬×50mm厚木跳板做支撐架底部的的操作平臺(tái),木跳板鋪設(shè)后用鐵絲與鋼管鋼綁扎牢固。腳手板采用對接平鋪,接頭處設(shè)兩根橫向水平桿,腳手板端部探頭長度外伸為150mm。四、施工進(jìn)度計(jì)劃本工程消防連廊施工根據(jù)最新調(diào)整后的施工總進(jìn)度計(jì)劃,消防連廊處結(jié)構(gòu)施工計(jì)劃如下:(1) 13層結(jié)構(gòu)計(jì)劃施工日期為:2012年8月30日至2012年9月30日;(2) 16層結(jié)構(gòu)計(jì)劃施工日期為:2012年7月15日至2012年8月15日;五、消防連廊施工方法:(一)
14、、懸挑鋼梁支撐架的搭設(shè):1、搭設(shè)順序?yàn)椋悍啪€定位安裝懸挑鋼梁固定懸挑鋼梁斜拉鋼絲繩連接搭設(shè)模板排架及施工腳手架安裝架體底部安全平網(wǎng)和施工腳手架立網(wǎng)檢查驗(yàn)收。2、懸挑鋼梁安放應(yīng)按懸挑腳手架的立桿縱距和排距要求進(jìn)行定位和放線。 3、固定鋼梁尾部的二道f18錨環(huán)的布置根據(jù)主梁的位置確定;形錨環(huán)要與樓板主筋牢固焊接,防止?jié)矒v樓板混凝土?xí)r移位。4、將工字鋼主梁置入形錨環(huán)內(nèi),采用f18形套環(huán)與工字鋼和錨環(huán)焊接,錨環(huán)與套環(huán)雙面滿焊長度為160mm,且套環(huán)與工字鋼雙面滿焊,以確保鋼梁不位移。5、主梁靠框架梁處焊接15(30)cm長工字鋼擋腳,防止主梁工字鋼滑動(dòng),安裝斜拉鋼絲繩消除工字鋼的彈性保證懸挑工字鋼的剛
15、度。6、模板排架和施工腳手架搭設(shè)時(shí),將立桿底部套入橫梁上焊接的f25mm短鋼筋內(nèi),同時(shí)在立桿下部距底座上部不大于0.15m處設(shè)置掃地桿。(二)、連廊排架和施工腳手架搭設(shè)1、連廊模板支撐排架搭設(shè)順序?yàn)椋悍啪€定位立桿掃地桿中部縱、橫桿頂板承重桿剪刀撐。2、立桿的底部設(shè)置縱橫掃地桿,掃地桿距橫梁高度為0.15m。3、橫竿挑出外立桿的長度分別為0.15m,另一端與結(jié)構(gòu)剪力墻拉結(jié)。4、立桿及縱向水平桿的接頭要互相錯(cuò)開(或者使用整根鋼管不設(shè)置接頭),錯(cuò)開距離不少于0.5m;立桿的接頭必須使用對接扣件。5、排架和施工腳手架剪刀撐垂直連廊方向每間隔兩道工字鋼設(shè)置一道剪刀撐,排架立桿和施工腳手架外側(cè)縱向立桿位置
16、設(shè)置連續(xù)剪刀撐,剪刀撐斜桿與水平面的傾角應(yīng)在45º60º之間。6、剪刀撐斜桿的接頭必須采用旋轉(zhuǎn)扣件連接,搭接長度不小于1.0m,且不少于3個(gè)扣件。固定斜桿的旋轉(zhuǎn)扣件的中心線距主節(jié)點(diǎn)的距離不得大于0.15m。(三)連廊模板安裝1、本連廊模板采用15mm厚木模板現(xiàn)場制作拼裝;拼縫采用平縫,模板釘在木方上,拼縫要齊整、緊密無間隙;接槎轉(zhuǎn)角處采用經(jīng)平刨處理光滑的40×80mm木楞鑲嵌收口;支撐系統(tǒng)f48×3.0mm鋼管支撐。2、模板接頭要錯(cuò)開,主梁與次梁交接處要做安裝的連接企口,并在顯著地地方標(biāo)出中心線。配制各種類型的模板要標(biāo)準(zhǔn)化、定型化,模板的橫檔與框材的截面
17、厚度要盡可能一致,這樣有利于支模方便。3、模板應(yīng)平整、完好無損,每次使用前要清除模板上的垃圾雜物,涂刷隔離劑;模板的底部要留有清掃口,以便清除垃圾。模板安裝完畢后,要將模板內(nèi)的垃圾雜物清除干凈,以利下道工序的進(jìn)行。4、模板的拼縫要密實(shí),必要時(shí)在模板內(nèi)側(cè)采用膠帶紙粘貼。特別是交角處要采用雙面膠帶密封,以防跑漿;模板底部同上次混凝土的接合處要處理平整,過大的縫隙可用砂漿堵塞,防止混凝土澆筑時(shí)漏漿而造成根部“爛腳”的現(xiàn)象。5、所有模板的支撐必須有足夠的強(qiáng)度、剛度和穩(wěn)定性,并做到橫平豎直。上口標(biāo)高用水準(zhǔn)儀復(fù)測后標(biāo)記,用以控制混凝土澆注時(shí)的水平高度。6、連廊板底模制作時(shí)要確保截面尺寸及角度的準(zhǔn)確性。接槎
18、陽角處采用經(jīng)平刨處理后光滑的40×80mm木方鑲嵌收口。7、為保證結(jié)構(gòu)幾何尺寸的準(zhǔn)確性,模板支好后,必須檢查模內(nèi)尺寸、垂直度及標(biāo)高、插筋位置,并對模板內(nèi)鋼筋沖洗干凈,經(jīng)監(jiān)理驗(yàn)收合格后才能進(jìn)入下道工序。8、模板安裝支撐完畢后,必須進(jìn)行標(biāo)高和軸線的復(fù)核,并經(jīng)監(jiān)理驗(yàn)收合格后方可進(jìn)行下道工序的施工。 9、1.2米高欄板模板施工采用ø14穿墻對拉螺桿加固,對拉螺桿豎向間距300mm,橫向間距500mm。(四)、連廊混凝土施工 混凝土澆筑采用56米汽車泵送混凝土,為了加快工程施工進(jìn)度和保證連廊混凝土施工質(zhì)量,連廊混凝土等級(jí)均在設(shè)計(jì)基礎(chǔ)上提高一個(gè)等級(jí)外加早強(qiáng)劑。以連廊同條件試塊和回彈結(jié)果
19、確定,待強(qiáng)度達(dá)到設(shè)計(jì)標(biāo)準(zhǔn)后放可拆除連廊模板。混凝土澆筑施工前將梁窩內(nèi)雜物清除、表面浮渣、松散砼剔除干凈,鋼筋銹跡和水泥漿清除干凈,露出堅(jiān)實(shí)粗糙的面,并沖洗干凈,排除積水,灑水濕潤48小時(shí)使其充分濕潤。振搗砼時(shí)應(yīng)充分振搗密實(shí),使新、老砼緊密結(jié)合六、主要施工材料和勞動(dòng)力用量情況(一)、8、9#合計(jì)主要施工材料配置序號(hào)材料名稱規(guī)格型號(hào)數(shù)量備注1工字鋼20a32噸2鋼管Ø48×3.028噸3扣件Ø485040個(gè)含十字扣件、旋轉(zhuǎn)扣件、接頭扣件4密目網(wǎng)800目700m25木模板1.83×0.915×0.015m500m26木方3×0.04
20、5;0.08m330根(二)、主要?jiǎng)趧?dòng)力計(jì)劃表工種模板支架安裝模板安裝混凝土施工電焊工2人架子工10人木工8人混凝土工 8普工64 5七、質(zhì)量保證措施(一)、模板質(zhì)量保證措施模板的安裝必須符合混凝土結(jié)構(gòu)工程施工及驗(yàn)收規(guī)范(GB 50204-2002)及相關(guān)規(guī)范要求。即”模板及其支架應(yīng)具有足夠的承載能力、剛度和穩(wěn)定性,能可靠地承受澆筑混凝土的重量、側(cè)壓力以及施工荷載”。1、安裝消防連廊模板及其支架時(shí),支架底部的鋼梁應(yīng)有承受連廊荷載的承載能力。(1) 檢查數(shù)量:全數(shù)檢查。(2) 檢驗(yàn)方法:對照模板設(shè)計(jì)文件和施工技術(shù)方案觀察。2、在涂刷模板隔離劑時(shí),不得沾污鋼筋和混凝土接槎處。(1) 檢查
21、數(shù)量:全數(shù)檢查。(2) 檢驗(yàn)方法:觀察。3、底模及其支撐架拆除時(shí)的混凝土強(qiáng)度必須符合設(shè)計(jì)要求;當(dāng)設(shè)計(jì)無具體要求時(shí),混凝土強(qiáng)度必須達(dá)到設(shè)計(jì)強(qiáng)度的100%。檢驗(yàn)方法:檢查同條件養(yǎng)護(hù)試件強(qiáng)度試驗(yàn)報(bào)告。4、模板安裝應(yīng)滿足下列要求: 模板的接縫不應(yīng)漏漿;在澆筑混凝土前,木模板應(yīng)澆水濕潤,但模板內(nèi)不應(yīng)有積水;模板與混凝土的接觸面應(yīng)清理干凈并涂刷隔離劑;澆筑混凝土前,模板內(nèi)的雜物應(yīng)清理干凈;(1) 檢查數(shù)量:全數(shù)檢查。(2) 檢驗(yàn)方法:觀察。5、對跨度不小于4m 的現(xiàn)澆鋼筋混凝土梁、板,其模板應(yīng)按要求起拱。(1) 檢查數(shù)量:按規(guī)范要求的檢驗(yàn)批(在同一檢驗(yàn)批內(nèi),對梁,應(yīng)抽查構(gòu)件數(shù)量的10,且不應(yīng)少于
22、3 件;對板,應(yīng)按有代表性的自然間抽查10,且不得小于3 間。)(2) 檢驗(yàn)方法:水準(zhǔn)儀或拉線、鋼尺檢查。(二)、排架和腳手架搭設(shè)的技術(shù)要求與允許偏差1、懸挑鋼梁固定堅(jiān)實(shí),與樓板連接牢固;2、立桿垂直度: = 3mm;3、柱距:± 20mm;4、排距:± 20mm;5、步距:± 20mm;6、一根縱向水平桿的兩端高差:± 20mm7、同一跨內(nèi)、外兩根縱向水平桿高差:±10mm;8、橫向水平桿外伸長度:±50mm;9、各扣件距主節(jié)點(diǎn)距離:150mm;10、縱向水平桿上的對接扣件距離主節(jié)點(diǎn):縱距;11、扣件螺絲擰緊力矩
23、:4065Nm;12、剪刀撐與地面的傾角:45º60º;八、安全文明保證措施(一)、模板及支架裝拆安全技術(shù)措施1. 模板、支架拆除時(shí)嚴(yán)禁隨地拋擲,必須經(jīng)受料平臺(tái)吊至地面。2. 模板應(yīng)堆放整齊,堆放高度不得超過1.5m,堆放時(shí)必須有防傾倒措施。3. 支模前必須搭好排架和腳手架。4. 支模施工時(shí),6級(jí)以上大風(fēng)要停止施工。5. 澆筑混凝土前必須檢查支撐是否可靠、扣件是否松動(dòng)。澆筑混凝土?xí)r必須由模板支設(shè)班組設(shè)專人看模,隨時(shí)檢查支撐是否變形、松動(dòng),并組織及時(shí)恢復(fù)。經(jīng)常檢查支設(shè)模板吊鉤、斜支撐及平臺(tái)連接處螺栓是否松動(dòng),發(fā)現(xiàn)問題及時(shí)組織處理。6. 鋼管、模板嚴(yán)禁大量集中堆放在支架上,防止
24、支架因集中受荷失穩(wěn)。7. 消防連廊為懸挑結(jié)構(gòu),結(jié)構(gòu)混凝土強(qiáng)度必須達(dá)到設(shè)計(jì)及規(guī)范的要求,方可拆除模板及支撐。8. 拆模時(shí)操作人員必須掛好、系好安全帶。9. 模板拆除后要及時(shí)送至摟面或地面,嚴(yán)禁留有未拆除的懸空模板。10. 拆除模板、支架時(shí),區(qū)域范圍內(nèi)要設(shè)置警戒線,并有專人監(jiān)護(hù)。(二)、排架及施工腳手架安全技術(shù)措施1、材質(zhì)及其使用的安全技術(shù)措施(1)扣件的緊固程度宜在4050Nm,并不大于65 Nm,對接扣件的抗拉承載力為3kN。對接扣件安裝時(shí)其開口應(yīng)向內(nèi),以防進(jìn)雨,直接扣件安裝時(shí)開口不得向下,以保證安全。(2)各桿件端頭伸出扣件蓋板邊緣不小于150mm。(3)鋼管有嚴(yán)重銹蝕、壓扁或裂紋的不得使用
25、,禁止使用的脆裂、變形、滑絲等現(xiàn)象的扣件。(4)外腳手架嚴(yán)禁鋼木混搭,禁止扣件、繩索、鋼絲、塑料混用。2、腳手架搭設(shè)的安全技術(shù)措施(1)搭設(shè)過程中劃出工作標(biāo)志區(qū),禁止行人進(jìn)入,統(tǒng)一指揮、上下呼應(yīng)、動(dòng)作協(xié)調(diào),嚴(yán)禁在無人指揮下作業(yè)。當(dāng)解開與另一人有關(guān)的扣件時(shí)必須告訴對方,并得到允許,以防墜落傷人。(2)腳手架及時(shí)與結(jié)構(gòu)拉接,以保證搭設(shè)過程安全,未完成腳手架在每日收工前,一定要確保架子穩(wěn)定。(3)腳手架必須配合施工進(jìn)度搭設(shè),一次搭設(shè)的高度不得超過相鄰連墻件以上兩步。(4)在搭設(shè)過程中應(yīng)由安全員、架子班長等進(jìn)行檢查、驗(yàn)收和簽證。每兩步驗(yàn)收一次,達(dá)到設(shè)計(jì)施工要求后掛合格牌。(5)、使用鋼絲繩時(shí),應(yīng)按正確
26、方法進(jìn)行,以避免鋼絲繩產(chǎn)生扭結(jié)。鋼絲繩切斷前應(yīng)在切口兩側(cè)用細(xì)鐵絲捆扎,以防切斷后繩頭松散。(6)、鋼絲繩夾不得在鋼絲繩上交替布置,三個(gè)鋼絲繩夾的間距為15cm,離套環(huán)最近處的繩夾應(yīng)盡可能緊靠套環(huán),緊固繩夾時(shí)要考慮每個(gè)繩夾的合理受力,離套環(huán)最遠(yuǎn)處的繩夾不得首先單獨(dú)緊固。(7)、為了便于檢查接頭,在最后一個(gè)夾頭后50cm處安裝一個(gè)夾頭,并將鋼絲繩放出一個(gè)“安全彎”,接頭鋼絲繩發(fā)生滑動(dòng)時(shí),“安全彎”即被拉直,就應(yīng)當(dāng)立即采取措施調(diào)整鋼絲繩。(8)、預(yù)埋吊環(huán)位置必須準(zhǔn)確,吊環(huán)與樓板內(nèi)主筋必須焊接牢固。3、腳手架上施工作業(yè)的安全技術(shù)措施(1)結(jié)構(gòu)外腳手架每支搭一層,支搭完畢后,經(jīng)項(xiàng)目經(jīng)理部安全員驗(yàn)收合格后
27、方可使用,任何班組長和個(gè)人,未經(jīng)同意不得任意拆除腳手架部件。(2)嚴(yán)格控制施工荷載,腳手板上不得集中堆放荷載,施工荷載不得大于2kN/m,確保較大安全儲(chǔ)備。(3)結(jié)構(gòu)施工時(shí)宜采用單層作業(yè)。(4)各作業(yè)之間設(shè)置可靠的防護(hù)欄桿,防止墜落物體傷人。(5)定期檢查腳手架,發(fā)現(xiàn)問題和隱患,在施工作業(yè)前及時(shí)維修加固,以達(dá)到堅(jiān)固穩(wěn)定,確保施工安全。4、腳手架拆除的安全技術(shù)措施(1)腳手架搭拆人員必須是經(jīng)過考核的專業(yè)架子工,并持證上崗。連墻件應(yīng)在位于其上的全部可拆桿件都拆除之后才能拆除。(2)拆架前,全面檢查待拆腳手架,根據(jù)檢查結(jié)果,擬定出作業(yè)計(jì)劃,報(bào)請批準(zhǔn),進(jìn)行技術(shù)交底后才準(zhǔn)備工作。(3)架體拆除前,必須察
28、看施工現(xiàn)場環(huán)境,包括架空線路、外腳手架、地面的設(shè)施等各類障礙物、地錨、連墻桿及被拆除架體各吊點(diǎn)、附件、電器裝置情況,凡能提前拆除的盡量拆除掉。(4)拆除時(shí)應(yīng)劃出作業(yè)區(qū),周圍設(shè)繩綁圍欄或樹立警示標(biāo)志,地面設(shè)專人圍護(hù),禁止非作業(yè)人員進(jìn)入。(5)拆除時(shí)統(tǒng)一指揮、上下呼應(yīng)、動(dòng)作協(xié)調(diào),當(dāng)解開與另一人有關(guān)的扣件時(shí)必須先告訴對方并等到允許,以防墜落傷人。(6)拆架時(shí)不得中途換人,如必須換人時(shí),應(yīng)將拆除情況交代清楚后方可離開。(7)每天拆架下班時(shí),不應(yīng)留下隱患部位。(8)拆架時(shí)嚴(yán)禁碰撞腳手架附件電源線,以防觸電事故。(9)在拆除過程中,凡松開連接的桿、配件應(yīng)及時(shí)拆除運(yùn)走,避免誤傷、無靠已松脫的桿件。拆除的桿、
29、配件嚴(yán)禁向下拋擲,應(yīng)吊至地面,同時(shí)做好配合協(xié)調(diào)工作,禁止單人進(jìn)行拆除較重桿件等危險(xiǎn)性作業(yè)。(10)所有桿件和扣件在拆除時(shí)分離,不準(zhǔn)在桿件上附著扣件或兩桿連著送至地面。(11)所有的腳手板,應(yīng)自外向里豎立搬運(yùn),以防止腳手板和垃圾物從高處墜落傷人。(12)拆除的零件要裝入容器內(nèi),用吊籃吊下;拆下的鋼管要綁扎牢靠,雙點(diǎn)吊起,嚴(yán)禁從高空拋擲。(13)六級(jí)風(fēng)以上(含六級(jí))時(shí)停止拆除腳手架施工。九、應(yīng)急救援預(yù)案(一)應(yīng)急預(yù)案處置措施:發(fā)生突發(fā)事件后,啟動(dòng)本項(xiàng)目部施工安全等突發(fā)事件應(yīng)急預(yù)案。主管領(lǐng)導(dǎo)和分管領(lǐng)導(dǎo)立即到位并采取相應(yīng)的措施,同時(shí)向當(dāng)?shù)赜嘘P(guān)部門報(bào)警,向政府主管部門報(bào)告。1、若工地發(fā)生懸挑腳手架坍塌事
30、故和作業(yè)人員高空墜落時(shí),要立即組織人員及時(shí)搶救,控制好事故現(xiàn)場,防止事態(tài)擴(kuò)大。2、撥打120急救中心電話,到現(xiàn)場搶救受傷人員,五四廠急救電話。3、急報(bào)公司有關(guān)應(yīng)急救援單位,采取有效的應(yīng)急救援措施。4、清理事故現(xiàn)場,檢查現(xiàn)場施工人員是否齊全,把事故受傷控制到最少。(二)、應(yīng)急救援組織機(jī)構(gòu)圖(三)、人員傷害現(xiàn)場臨時(shí)急救發(fā)生事故后,切不可驚慌失措,束手無策。應(yīng)迅速通知醫(yī)療部門,同時(shí)進(jìn)行簡單診斷。如果傷員處于昏迷狀態(tài),全身各組織嚴(yán)重缺氧,生命垂危,這時(shí)不能用整套常規(guī)方法進(jìn)行系統(tǒng)檢查,而只能用簡單的效的方法盡快對心跳、呼吸與瞳孔的情況作一判斷,以確定隨后的現(xiàn)場救治方法:1、觀察傷員是否還存在呼吸。可用手
31、或者纖維毛放在傷員鼻孔前,感受和觀察是否有氣體流動(dòng),同時(shí)觀察傷員的胸廓和腹部是否存在上下起伏的呼吸運(yùn)動(dòng)。2、檢查傷員是否還有心跳。可直接在心前區(qū)聽是否有心跳的心音,或摸頸動(dòng)脈、肱動(dòng)脈是否搏動(dòng)。3、查看瞳孔是否擴(kuò)大。人的瞳孔受到大腦控制,在正常情況下,瞳孔的大小可隨外界光線的強(qiáng)弱變化而自然調(diào)節(jié),使進(jìn)入眼內(nèi)的光線適中,在假死的狀態(tài)中。大腦細(xì)胞嚴(yán)重缺氧,機(jī)體處于死亡邊緣,整個(gè)調(diào)節(jié)系統(tǒng)失去了作用,瞳孔便自行擴(kuò)大,并且對光線強(qiáng)弱變化沒有反應(yīng)。現(xiàn)場急救有以下幾種方法:1)人工呼吸法具體操作按下列步驟進(jìn)行:a傷員平臥,解開衣領(lǐng),松開圍巾和緊身衣服,放松褲帶,以利呼吸時(shí)胸廓自然擴(kuò)張。在傷員的肩背下方墊軟物,使
32、傷員的頭部充分后仰,呼吸道盡量暢通,減少氣流的阻力,確保有效通氣量,還可以防止舌根陷落而堵塞氣流通道。用手指清除口腔中的異物,如假牙、分泌物、血塊和嘔吐物等,以免堵塞呼吸道。注意環(huán)境要安靜,冬季要保暖。b搶救者站在傷員的一側(cè),以近其頭部的手緊捏傷員的鼻子(避免漏氣)并將手掌外緣壓住額部,另一只手托在傷員頸部,將頸部上抬,頭部盡量上仰,鼻孔呈朝天位,使嘴巴張開準(zhǔn)備接受吹氣。c搶救者先吸一口氣,然后嘴緊貼傷員的嘴大口吹氣,同時(shí)觀察其胸部是否膨脹隆起,以確定吹氣是否有效和吹氣是否適度。d吹氣停止后,搶救者頭稍側(cè)轉(zhuǎn),并立即放松捏鼻子的手,讓氣體從傷員的鼻孔排除。此時(shí)注意胸部復(fù)原情況,傾聽呼氣聲,觀察有
33、無呼吸道梗阻。如此反復(fù)而有節(jié)律地人工呼吸,不可中斷。每分鐘應(yīng)進(jìn)行1216次。進(jìn)行人工呼吸時(shí)口對口吹氣的壓力要掌握好,開始時(shí)可略大些,頻率也可稍快些,經(jīng)過一二十次人工吹氣后逐漸減少壓力,只要維持傷員胸部輕度升起即可。如遇到傷員嘴巴掰不開的情況,可改用口對鼻孔吹氣的辦法,吹氣時(shí)壓力要稍大些,時(shí)間稍長些,效果相仿。采用這種方法,只有當(dāng)傷員出現(xiàn)自動(dòng)呼吸時(shí),方可停止。但要嚴(yán)密觀察,經(jīng)防出現(xiàn)再次停止呼吸。2)胸外心臟擠壓法按下列步驟進(jìn)行:a使傷員就近仰臥于硬板上或地上,注意保暖,解開傷員衣領(lǐng),使其頭部后仰側(cè)偏。b搶救者站在傷員左側(cè)或兩腿跨在病人的腰部兩側(cè)。c搶救者以一手掌根部置于傷員胸骨下1/3處,即中指
34、對準(zhǔn)其頸部凹陷的下緣,一手掌交叉重疊于該手背上,肘關(guān)節(jié)伸直。依靠體重和臂、肩部肌肉的力量,垂直用力,向脊柱方向沖擊性地用力施壓胸骨下段,使胸骨下段與其相連的肋骨下陷34cm,間接壓迫心臟,使心臟血液搏出。d擠壓后突然放松(要注意掌根不能離開胸壁),依靠胸廓的彈性,使胸骨復(fù)位。此時(shí)心臟舒張,大靜脈的血液就回流到心臟。以上兩種搶救方法適用范圍很廣,除電擊傷外,對遭雷擊、急性中毒、燒傷、心跳驟停等原因所引起的抑制或呼吸停止的傷員都可采用,有時(shí)兩種方法可交替進(jìn)行。3)出血救護(hù)創(chuàng)傷性出血急救步驟:a暫時(shí)止血發(fā)生創(chuàng)傷性出血時(shí),應(yīng)根據(jù)現(xiàn)場條件,及時(shí)正確地采取下列暫時(shí)性的止血方法止血。壓迫止血法抬高受創(chuàng)傷肢體
35、,在找不到消毒紗布和棉墊時(shí),可用清潔的手帕、毛巾或其他棉織品覆蓋在傷口表面,再用繃帶或布條加包扎止血。指壓止血法一般用于臨時(shí)性的動(dòng)脈止血。即用手指壓在動(dòng)脈出血的近心端。這種方法簡便、見效快,但不能持久。彈性止血帶止血當(dāng)肢體動(dòng)脈創(chuàng)傷出血,一般的止血包扎方法效果不理想時(shí),可以用彈性止血帶止血。b包扎固定對創(chuàng)傷處用消毒的敷料或清潔的棉紡品覆蓋包扎可以保護(hù)創(chuàng)口,預(yù)防感染,減少出血。當(dāng)肢體發(fā)生骨折時(shí),可用繃帶包扎夾板來固定受傷部位上下兩個(gè)關(guān)節(jié),減少損傷、疼痛,預(yù)防傷員休克。c運(yùn)送傷員到醫(yī)院傷員經(jīng)現(xiàn)場止血、包扎、固定后,應(yīng)盡快正確地運(yùn)送到醫(yī)院搶救。凡傷員受傷后,若局部出現(xiàn)疼痛、腫脹、功能障礙、畸形變化,就
36、提示有骨折的可能。此時(shí)應(yīng)對受傷的部位進(jìn)行止血、包扎、固定以后再搬運(yùn)。否則,受傷部位可能因搬運(yùn)的不正確或振動(dòng)而使創(chuàng)傷加重。嚴(yán)重創(chuàng)傷伴有大出血傷員,在搬運(yùn)過程中應(yīng)平臥,傷員頭部可放置冰袋或帶冰帽,路途中要盡量避免震蕩。高處墜落致傷傷員,常疑有脊椎受傷,所以搬運(yùn)時(shí)一定要使傷員平臥在硬板上,切忌只搬傷員的兩肩和兩腿,以避免在搬運(yùn)過程中軀干過分屈曲或伸展,使已受傷脊椎移位,甚至斷裂,造成截癱,導(dǎo)致死亡。肢體受到嚴(yán)重?cái)D壓致傷的傷員,經(jīng)現(xiàn)場處理后,送醫(yī)院過程中,不應(yīng)局部按摩、熱敷,也不能隨便活動(dòng)。胸部受傷的傷員,要警惕肋骨骨折和臟器出血的可能,這類傷員一定要平穩(wěn)運(yùn)送,密切觀察。(四)、救援路線圖十、型鋼懸挑
37、腳手架計(jì)算書型鋼懸挑扣件式鋼管腳手架的計(jì)算依據(jù)建筑施工扣件式鋼管腳手架安全技術(shù)規(guī)范(JGJ130-2011)、建筑結(jié)構(gòu)荷載規(guī)范(GB 50009-2001)、鋼結(jié)構(gòu)設(shè)計(jì)規(guī)范(GB 50017-2003)、建筑施工安全檢查評(píng)分標(biāo)準(zhǔn)(JGJ59-2011)、建筑施工高處作業(yè)安全技術(shù)規(guī)范(JGJ80-91) 以及本工程的施工圖紙。(一)、參數(shù)信息:1.腳手架參數(shù)腳手架搭設(shè)高度為按 6 m,立桿采用單立桿;搭設(shè)尺寸為:立桿的縱距為 0.8m,立桿的橫距為0.9m,立桿的步距為0.9 m;內(nèi)排架距離墻長度為1.40 m;腳手架沿墻縱向長度為 35.00 m;采用的鋼管類型為 48×3.0; 橫
38、桿與立桿連接方式為單扣件;取扣件抗滑承載力系數(shù) 1.00;連墻件布置按兩步兩跨,豎向間距 1.8 m,水平間距1.6 m進(jìn)行計(jì)算,采用扣件連接;連墻件連接方式為雙扣件;2.荷載參數(shù) 鋼筋混凝土標(biāo)準(zhǔn)值每立方混凝土1.5KN,混凝土自重標(biāo)準(zhǔn)值24KN/m3。 混凝土結(jié)構(gòu)自重均布荷載值為7.46KN/M2 施工人員荷載為0.25KN/M2(不含機(jī)械設(shè)備) 鋼管扣件、模板均布荷載值為1.3 KN/M2 合計(jì):每平方米均布荷載為9.01 KN/M2施工均布荷載(kN/m2):9.000;腳手架用途:消防連廊模板支撐體系;同時(shí)施工層數(shù):1 層;3.風(fēng)荷載參數(shù)計(jì)算中不考慮風(fēng)荷載作用;4.靜荷載參數(shù)每米立桿承
39、受的結(jié)構(gòu)自重荷載標(biāo)準(zhǔn)值(kN/m):0.1489;腳手板自重標(biāo)準(zhǔn)值(kN/m2):0.300;欄桿擋腳板自重標(biāo)準(zhǔn)值(kN/m):0.150;安全設(shè)施與安全網(wǎng)自重標(biāo)準(zhǔn)值(kN/m2):0.005;腳手板鋪設(shè)層數(shù):1 層;腳手板類別:竹笆片腳手板;欄桿擋板類別:欄桿、竹笆片腳手板擋板;5.水平懸挑支撐梁懸挑水平鋼梁采用20a號(hào)工字鋼,其中建筑物外懸挑段長度4m,建筑物內(nèi)錨固段長度 2 m。與樓板連接的螺栓直徑(mm):18.00;樓板混凝土標(biāo)號(hào):C25;6.拉繩與支桿參數(shù) 鋼絲繩安全系數(shù)為:6.000;鋼絲繩與墻距離為(m):3.000;懸挑水平鋼梁采用鋼絲繩與建筑物拉結(jié),最里面面鋼絲繩距離建筑物
40、 1.2 m。 (二)、大橫桿的計(jì)算:按照扣件式鋼管腳手架安全技術(shù)規(guī)范(JGJ130-2011)規(guī)定,大橫桿按照三跨連續(xù)梁進(jìn)行強(qiáng)度和撓度計(jì)算,大橫桿在小橫桿的上面。將大橫桿上面的腳手板自重和施工活荷載作為均布荷載計(jì)算大橫桿的最大彎矩和變形。1.均布荷載值計(jì)算大橫桿的自重標(biāo)準(zhǔn)值:P1=0.033 kN/m ;腳手板的自重標(biāo)準(zhǔn)值:P2=0.3×0.9=0.27 kN/m ;活荷載標(biāo)準(zhǔn)值: Q=9×0.9=8.1 kN/m;靜荷載的設(shè)計(jì)值: q1=1.2×0.033+1.2×0.27=0.364 kN/m;活荷載的設(shè)計(jì)值: q2=1.4×8.1=11
41、.34 kN/m; 圖1 大橫桿設(shè)計(jì)荷載組合簡圖(跨中最大彎矩和跨中最大撓度) 圖2 大橫桿設(shè)計(jì)荷載組合簡圖(支座最大彎矩)2.強(qiáng)度驗(yàn)算跨中和支座最大彎距分別按圖1、圖2組合。跨中最大彎距計(jì)算公式如下: 跨中最大彎距為M1max=0.08×0.364×0.82+0.10×11.34×0.82 =0.744 kN.m;支座最大彎距計(jì)算公式如下: 支座最大彎距為 M2max= -0.10×0.364×0.82-0.117×11.34×0.82 =-0.872 kN.m;選擇支座彎矩和跨中彎矩的最大值進(jìn)行強(qiáng)度驗(yàn)算:=Ma
42、x(0.744×106,0.872×106)/4490=194.209 N/mm2;大橫桿的最大彎曲應(yīng)力為 = 194.209 N/mm2 小于 大橫桿的抗壓強(qiáng)度設(shè)計(jì)值 f=205 N/mm2,滿足要求!3.撓度驗(yàn)算:最大撓度考慮為三跨連續(xù)梁均布荷載作用下的撓度。計(jì)算公式如下: 其中:靜荷載標(biāo)準(zhǔn)值: q1= P1+P2=0.033+0.27=0.303 kN/m; 活荷載標(biāo)準(zhǔn)值: q2= Q =8.1 kN/m;最大撓度計(jì)算值為:= 0.677×0.303×8004/(100×2.06×105×107800)+0.990
43、215;8.1×8004/(100×2.06×105×107800) = 1.517 mm;大橫桿的最大撓度 1.517 mm 小于 大橫桿的最大容許撓度 800/150 mm與10 mm,滿足要求!(三)、小橫桿的計(jì)算:因?yàn)榇藭r(shí)小橫桿沒有受到上部結(jié)構(gòu)傳來的力的作用,所以,小橫桿不需要進(jìn)行驗(yàn)算。(四)、扣件抗滑力的計(jì)算:按規(guī)范表5.1.7,直角、旋轉(zhuǎn)單扣件承載力取值為8.00kN,按照扣件抗滑承載力系數(shù)1.00,該工程實(shí)際的旋轉(zhuǎn)單扣件承載力取值為8.00kN。縱向或橫向水平桿與立桿連接時(shí),扣件的抗滑承載力按照下式計(jì)算(規(guī)范5.2.5): R Rc 其中
44、Rc - 扣件抗滑承載力設(shè)計(jì)值,取8.00 kN;R - 縱向或橫向水平桿傳給立桿的豎向作用力設(shè)計(jì)值;大橫桿的自重標(biāo)準(zhǔn)值: P1 = 0.033×0.8/2=0.013 kN;腳手板的自重標(biāo)準(zhǔn)值: P3 = 0.3×0.9×0.8/2=0.108 kN;活荷載標(biāo)準(zhǔn)值: Q = 9×0.9×0.8 /2 = 3.24 kN;荷載的設(shè)計(jì)值: R=1.2×(0.013+0.108)+1.4×3.24=4.682 kN;R < 8.00 kN,單扣件抗滑承載力的設(shè)計(jì)計(jì)算滿足要求! (五)、腳手架立桿荷載的計(jì)算: 作用于腳手架的
45、荷載包括靜荷載、活荷載和風(fēng)荷載。靜荷載標(biāo)準(zhǔn)值包括以下內(nèi)容: (1)每米立桿承受的結(jié)構(gòu)自重標(biāo)準(zhǔn)值,為0.1489kN/m NG1 = 0.1489+(0.80×0/2)×0.033/0.90×6.00 = 0.893kN;(2)腳手板的自重標(biāo)準(zhǔn)值;采用竹笆片腳手板,標(biāo)準(zhǔn)值為0.3kN/m2 NG2= 0.3×1×0.8×(0.9+0.3)/2 = 0.144 kN;(3)欄桿與擋腳手板自重標(biāo)準(zhǔn)值;采用欄桿、竹笆片腳手板擋板,標(biāo)準(zhǔn)值為0.15kN/m NG3 = 0.15×1×0.8/2 = 0.06 kN;(4)吊掛
46、的安全設(shè)施荷載,包括安全網(wǎng);0.005 kN/m2 NG4 = 0.005×0.8×6 = 0.024 kN;經(jīng)計(jì)算得到,靜荷載標(biāo)準(zhǔn)值 NG =NG1+NG2+NG3+NG4 = 1.121 kN;活荷載為施工荷載標(biāo)準(zhǔn)值產(chǎn)生的軸向力總和,立桿按一縱距內(nèi)施工荷載總和的1/2取值。經(jīng)計(jì)算得到,活荷載標(biāo)準(zhǔn)值 NQ= 9×0.9×0.8×1/2 = 3.24 kN;風(fēng)荷載標(biāo)準(zhǔn)值按照以下公式計(jì)算 其中 Wo - 基本風(fēng)壓(kN/m2),按照建筑結(jié)構(gòu)荷載規(guī)范(GB50009-2001)的規(guī)定采用: Wo = 0.45 kN/m2; Uz - 風(fēng)荷載高度變化
47、系數(shù),按照建筑結(jié)構(gòu)荷載規(guī)范(GB50009-2001)的規(guī)定采用: Uz= 1 ; Us - 風(fēng)荷載體型系數(shù):取值為1.128;經(jīng)計(jì)算得到,風(fēng)荷載標(biāo)準(zhǔn)值 Wk = 0.7 ×0.45×1×1.128 = 0.355 kN/m2;不考慮風(fēng)荷載時(shí),立桿的軸向壓力設(shè)計(jì)值為 Nd = 1.2NG+1.4NQ = 1.2×1.121+ 1.4×3.24 = 5.882 kN;風(fēng)荷載設(shè)計(jì)值產(chǎn)生的立桿段彎矩 MW 為 Mw = 0.85 ×1.4WkLah2/10 =0.850 ×1.4×0.355×0.8×
48、 0.92/10 = 0.027 kN.m;(六)、立桿的穩(wěn)定性計(jì)算: 不考慮風(fēng)荷載時(shí),立桿的穩(wěn)定性計(jì)算公式為: 立桿的軸向壓力設(shè)計(jì)值 :N = 5.882 kN;計(jì)算立桿的截面回轉(zhuǎn)半徑 :i = 1.59 cm;計(jì)算長度附加系數(shù)參照扣件式規(guī)范表5.3.3得 :k = 1.155 ;當(dāng)驗(yàn)算桿件長細(xì)比時(shí),取塊1.0;計(jì)算長度系數(shù)參照扣件式規(guī)范表5.3.3得 : = 1.5 ;計(jì)算長度 ,由公式 lo = k××h 確定 :l0 = 1.559 m;長細(xì)比 Lo/i = 98 ;軸心受壓立桿的穩(wěn)定系數(shù),由長細(xì)比 lo/i 的計(jì)算結(jié)果查表得到 := 0.603 ;立桿凈截面面積
49、: A = 4.24 cm2;立桿凈截面模量(抵抗矩) :W = 4.49 cm3;鋼管立桿抗壓強(qiáng)度設(shè)計(jì)值 :f =205 N/mm2; = 5882/(0.603×424)=23.005 N/mm2;立桿穩(wěn)定性計(jì)算 = 23.005 N/mm2 小于 立桿的抗壓強(qiáng)度設(shè)計(jì)值 f = 205 N/mm2,滿足要求!(七)、連墻件的計(jì)算: 因不考慮風(fēng)荷載連墻件的軸向力設(shè)計(jì)值僅取連墻件約束腳手架平面外變形所產(chǎn)生的軸向力設(shè)計(jì)值N0,對于雙排架取5kN, 小于單扣件抗滑移承載力設(shè)計(jì)值,故連墻件的軸向力無需驗(yàn)算!(八)、懸挑梁的受力計(jì)算:懸挑腳手架的水平鋼梁按照帶懸臂的連續(xù)梁計(jì)算。懸臂部分受腳手
50、架荷載N的作用,里端B為與樓板的錨固點(diǎn),A為墻支點(diǎn)。 本方案中,腳手架排距為900mm,內(nèi)排腳手架距離墻體300mm,支拉斜桿的支點(diǎn)距離墻體為 1200mm,水平支撐梁的截面慣性矩I = 2370 cm4,截面抵抗矩W = 237 cm3,截面積A = 35.5 cm2。受腳手架集中荷載 N=1.2×1.121 +1.4×3.24 = 5.882 kN;水平鋼梁自重荷載 q=1.2×35.5×0.0001×78.5 = 0.334 kN/m; 懸挑腳手架示意圖 懸挑腳手架計(jì)算簡圖經(jīng)過連續(xù)梁的計(jì)算得到 懸挑腳手架支撐梁剪力圖(kN) 懸挑腳手架支
51、撐梁彎矩圖(kN.m) 懸挑腳手架支撐梁變形圖(mm)各支座對支撐梁的支撐反力由左至右分別為:R1 = 9.316 kN; R2 = 4.276 kN; R3 = 0.176 kN。 最大彎矩 Mmax= 1.309 kN.m;最大應(yīng)力 =M/1.05W+N/A= 1.309×106 /( 1.05 ×237000 )+ 5.882×103 / 3550 = 6.918 N/mm2;水平支撐梁的最大應(yīng)力計(jì)算值 6.918 N/mm2 小于 水平支撐梁的抗壓強(qiáng)度設(shè)計(jì)值 215 N/mm2,滿足要求!(九)、懸挑梁的整體穩(wěn)定性計(jì)算: 水平鋼梁采用20a號(hào)工字鋼,計(jì)算公
52、式如下 其中b - 均勻彎曲的受彎構(gòu)件整體穩(wěn)定系數(shù),按照下式計(jì)算: b = 570 ×11.4×100× 235 /( 1200×200×235) = 2.71由于b大于0.6,查鋼結(jié)構(gòu)設(shè)計(jì)規(guī)范(GB50017-2003)附表B,得到 b值為0.966。經(jīng)過計(jì)算得到最大應(yīng)力 = 1.309×106 /( 0.966×237000 )= 5.72 N/mm2;水平鋼梁的穩(wěn)定性計(jì)算 = 5.72 小于 f = 215 N/mm2 ,滿足要求!(十)、拉繩的受力計(jì)算:水平鋼梁的軸力RAH和拉鋼繩的軸力RUi按照下面計(jì)算 其中RUi
53、cosi為鋼繩的 拉力對水平桿產(chǎn)生的軸壓力。各支點(diǎn)的支撐力 RCi=RUisini按照以上公式計(jì)算得到由左至右各鋼繩拉力分別為:RU1=10.034 kN;(十一)、拉繩的強(qiáng)度計(jì)算:鋼絲拉繩(支桿)的內(nèi)力計(jì)算:鋼絲拉繩(斜拉桿)的軸力RU均取最大值進(jìn)行計(jì)算,為RU=10.034 kN 選擇6×19鋼絲繩,鋼絲繩公稱抗拉強(qiáng)度1700MPa,直徑14mm。 其中Fg- 鋼絲繩的容許拉力(kN); Fg - 鋼絲繩的鋼絲破斷拉力總和(kN),查表得Fg123KN; - 鋼絲繩之間的荷載不均勻系數(shù),對6×19、6×37、6×61鋼絲繩分別取0.85、0.82和0.8。0.85; K - 鋼絲繩使用安全系數(shù)。K6。得到:Fg=17.425KN>Ru10.034KN。經(jīng)計(jì)算,選此型號(hào)鋼絲繩能夠滿足要求。鋼絲拉繩(斜拉桿)的拉
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
- 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
- 5. 人人文庫網(wǎng)僅提供信息存儲(chǔ)空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
- 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
- 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 校外供餐經(jīng)費(fèi)管理制度
- 我的一次志愿者經(jīng)歷作文(11篇)
- 隱私權(quán)與安全-洞察及研究
- 建筑工程材料試題集
- 環(huán)境友好技術(shù)應(yīng)用研究表
- 品牌影響力指數(shù)表(品牌)
- java異常處理面試題及答案歸納
- 產(chǎn)品質(zhì)量檢測合格證明書(8篇)
- 全國地理競賽試題及答案
- 人力資源行業(yè)特別聲明與工作證明(6篇)
- 2025年電大專科行政管理管理學(xué)基礎(chǔ)試題及答案
- 委托他人簽租房合同協(xié)議
- 2025年山東省聊城市東昌府區(qū)中考一模數(shù)學(xué)試卷
- 計(jì)量設(shè)備管理制度規(guī)范
- 基本級(jí)執(zhí)法資格考試訓(xùn)練題練習(xí)試題附答案
- 消防泵房安全管理制度及操作規(guī)程
- 水利工程標(biāo)準(zhǔn)化管理規(guī)程第6部分:農(nóng)村水電站(江西省2022版)
- 2025年內(nèi)蒙古興安銀鉛冶煉有限公司招聘筆試參考題庫含答案解析
- 大學(xué)生畢業(yè)代表演講稿
- 中成藥處方大全-僅作參考
- 凈水機(jī)產(chǎn)品培訓(xùn)
評(píng)論
0/150
提交評(píng)論