




版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
福建閩安投資工程有限公司第43頁共43頁湖光路13號消防系統設備集成及改造項目工程施工組織設計目錄一、消防工程概況·····························································································31.1工程概況············································································································31.2工程內容············································································································31.3工程重點難點··································································································3二、編制依據········································································································6三、施工部署········································································································73.1施工組織總體部署·························································································73.2工程管理機構職責劃分···············································································73.2.1管理機構圖·······································································································73.2.2項目管理班子配備情況表·············································································83.2.3主要管理及技術人員職責說明·····································································9四、工程計劃進度安排與控制·································································104.1工程進度控制·······························································································104.1.1工程進度計劃··································································································104.1.2項目進度復核··································································································104.1.3月工程報告······································································································104.2勞動力投入計劃表······················································································11五、工程施工管理措施··················································································125.1質量要求············································································································125.1.1質量保證體系·····································································································125.1.2質量保證具體環節····························································································135.2文檔管理············································································································145.3技術管理············································································································145.3.1保證工程進度措施··························································································155.3.2保證施工安全措施··························································································165.3.3消防保衛措施···································································································185.3.4成品及設備部件的保護措施·········································································195.3.5環境保護措施···································································································195.3.6冬季施工措施···································································································19六、工程實施·········································································································206.1工程實施步驟···································································································206.1.1工程實施階段······································································································216.1.2糾正和預防措施··································································································216.1.3質量記錄···············································································································216.1.4檢驗和試驗··········································································································21施工機械設備配備······················································································227.1機械設備的配置·····························································································227.2設備操作及保養維修···················································································22八、工程施工規范及工藝··············································································248.1消防報警、聯動系統部分·······································································248.1.1施工工藝流程····································································································248.1.2施工技術要求····································································································248.1.3工程調試驗收····································································································318.2消防噴灑系統部分························································································338.2.1施工工藝流程····································································································33九、工程檔案··········································································································36十、系統保修和維護服務··············································································3710.1售后服務········································································································3710.2售后服務措施······························································································38消防工程概況1.1工程概況本施工組織針對湖光路13號消防系統設備集成及改造項目工程實際情況編制,由于本工程為廈門市思明區湖光路13號原為成品煙倉庫現將改造為辦公樓。占地面積:1231.36㎡總建筑面積:6156.8㎡.本項目消防按多層公共建筑進行防火設計統一編制施工組織。1.2工程內容火災自動報警及控制系統:火災自動報警及控制系統改造主要包括煙感探測器、手動報警按鈕、聲光報警器、信號模塊等設備的布位、安裝及調試,及配管配線,以達到消防規范的要求。對所有的報警設備在報警控制器主機中進行相應的編程,來滿足報警系統的聯動關系要求。噴淋系統中設置的水流指示器、信號閥、報警閥組等設備在報警控制器主機中進行相應的編程,來滿足報警系統的聯動關系要求。室內消防給水、自動噴淋滅火系統:原建筑室外消火栓給水系統不作改變,室內消火栓在每層增加2套消火栓滅火箱,新增加噴淋滅火系統,噴淋滅火系統管道自本建筑西北向下接入口誠大廈地下室噴淋系統。在此次工程中采用自動噴淋系統從消防栓系統主管道取水,通過濕式報警閥后加裝信號碟閥和水流指示器連接噴淋支管,來滿足消防規范要求。工程安裝、調試、檢測和維護1.3本工程重點難點(一)、系統的聯動調試確認單機、部件及被聯動控制的各專業設備,其獨立功能全部正常后,可進行系統聯動調試。系統聯動調試應由建設主管單位主持,工程監理在場,各施工單位、各專業、各工種等聯合參加,共同進行。1.自動報警:在系統全程范圍內,各種設備操作正常無誤,要求各種報警信號及時準確,所打印的記錄應清晰完整。2、火警事故廣播:應按實際安裝數量全部進行下列功能檢驗:開通緊急廣播擴音機,插入話筒或錄音帶。(1)消防控制室選層廣播:例如:選定開通B層的火警事故廣播,B層及與其上下相鄰的A層、C層,均應能聽到廣播,此外的其它各層都應不能聽到廣播。否則不正常;(2)共用揚聲器系統強切試驗:當報警系統從巡檢狀態轉入火警狀態時,應能將該共用揚聲器的背景音樂停止,立即轉入火警事故廣播的狀態。否則不正常;(3)備用擴音器切換功能試驗:如果系統內有兩套(或以上)火警事故廣播設備,當其中一套設備突然損壞時,應能夠自動或手動地切換到另一套備用設備上工作。否則不正常。以上試驗,語音應清楚,錄放功效正常,有關現場及控制室的監聽器均應正常收聽。3、自動滅火系統:(1)室內消火栓的功能試驗,應在出水壓力符合防火規范的條件下進行:a、 主泵、備用泵轉換,運行1~3次;b、 消防控制室內操作,啟、停泵1~3次;c、 消火栓按鈕操作啟泵,按5%~10%的比例抽驗。以上各項控制功能、動作均應正常,信號均應及時準確。(2)自動噴水滅火系統的抽驗:a、 主泵與備用泵轉換運行1~3次;b、 消防控制室內操作啟、停泵1~3次;c、 對報警閥組、水流指示器、信號蝶閥、末端放水裝置等進行試驗。以上各項控制功能、動作均應正常,信號均應及時準確。以上各項控制功能、動作均應正常,信號均應及時準確。4、電動防火門、防火卷簾門控制裝置:應按實際安裝數量全部進行聯動控制功能試驗,各項控制功能、動作應正常,信號均應及時準確。5、通風、空調、和防排煙設備(包括風機和閥門)以上應按實際安裝數量全部進行聯動控制功能試驗,各項控制功能、動作均應正常,信號均應及時準確。6、消防通訊設備的檢驗,應符合下列要求:(1)控制室與設定部位的對講電話進行1~3次通話試驗;(2)電話插孔按實際安裝數量的100%進行通話試驗;(3)控制室與外線電話進行1~3次通話試驗。以上通話功能均應正常,語音應清晰。7、消防電梯的檢驗應進行1~2次電梯迫降至首層的人工控制和自動控制功能,動作均應正常。8、以上各項檢查中,如有不合格情況應及時修復或更換,并進行復驗。復驗時,對于有抽驗要求的部位,應進行加倍試驗。直至全部合格。9、應特別注意強切功能的設置,事關責任重大。無論圖紙設計有否具體要求,均須征得甲方配變電主管對強切方案的同意,并取得其簽字認可。電網強切功能是通過設置在配電柜“脫扣器”附近的專用模塊來實現的。當預定的火警信號到達該模塊時,脫扣器動作,從而實現對一切非消防用電的切斷。脫扣器動作所需的條件是“無源”或是“有源”,依不同類型的脫扣器而定。一般情況下,施工人員負責將規定的火警信號線送到模塊,并從該模塊引出符合聯動條件的導線。也可以在配變電主管(值班人員)的主持下將此導線接到脫扣器上。正式試驗此項功能時,該配變電主管應該在場。并且必須一次成功。通常情況下,電網強切的轉換開關應設定在“手動”狀態。10、系統全部調試完成后,應按公司規定填寫調試報告,并由甲方、監理單位、總包單位、設備廠家、消防系統施工單位等簽字確認。1.4工程管理目標1)本工程為本公司重點工程項目。2)實行以合同期為目標的項目法施工,全面履行工程合同,保工期、保質量、保交工。3)工程修改控制:項目中的工程修改控制由項目經理提出,工程修改控制將包括工程修改確認、文件檔案、審查、復核等。4)質量監督管理控制:為了保證工程質量,項目組配備質量監督工程師,按照ISO9001質量管理的目標、步驟、辦法完成質量監督管理。5)采取有效可靠的質量保證措施,創工程優良。6)建立強有力的項目領導班子,組織高素質的施工隊伍,采取先進的施工管理方法和施工技術。7)實現安全生產和文明施工。編制依據編制該工程技術標準依據為:2.1根據建設單位提供的施工圖、招標文件及其他技術文件;2.2我單位的消防系統深化設計圖紙;2.3參照以下國家標準、行業標準和地方標準;《火災自動報警系統設計規范》GB50116-98《自動噴水滅火系統設計規范》(2005版)GB50084-2001《簡易自動噴水滅火系統設計規程》 DBJ01-617-2004《建筑滅火配置設計規范》 GB50140-2005《建筑設計防火規范》GB50016-2006《火災自動報警系統施工驗收規范》 GB50166—92《自動噴水滅火系統施工及驗收規范》GB50261-2005《電氣安裝工程整理檢驗、評定標準》GBI303-88《建筑電氣工程施工質量驗收規范》GB50303-2002《火災報警設備檢驗規范》GB12978-91《建筑工程施工現場供用電安全規范》GB50194-93。《建筑施工安全檢查標準》JGJ59-99《建筑安裝工程資料管理規定》 DBJ01-51-2000《建筑安裝分項工程施工工藝規程》 DBJ01-26-96三、施工部署3.1施工組織總體部署質量目標:合格組織與管理:施工合同簽定后,我公司將成立工程項目部,實施管理和施工,由項目經理、項目技術負責人負責對工程的領導、指揮、協調、決策等事宜,對工程的進度、成本、質量、安全和現場文明施工等全部負責,進行技術交底,辦理工程洽商,匯集整理工程技術資料等。進度計劃:嚴格按雙方擬定的開竣工日期組織施工,密切配合整體工程及裝修進度計劃,根據各項工程的進度,協調制定本項工程的進度計劃表,保證不影響整體工期及進度。進場施工后,根據整體施工進度,編排本專業計劃表,并根據具體情況隨時調整。3.2管理機構職責劃分3.2.1管理機構圖項目部經理項目部經理施工班組總工預算員工程技術負責人施工班組合同管理員試驗員安全員質檢員資料員3.2.2項目管理班子配備情況表擬任崗位姓名職稱執業或職業資格證明證書名稱證書號級別專業項目經理高敏生工程師一級建造師0044034無項目技術負責人毛忠鵬高級工程師高級工程師證36204000355721無質檢員肖方營助工質檢員證BFZ301800無安全員林鎮權助工安全員證BFZ501840安全員級別:中級無預算員王碧娟助工造價員證閩07K01104預算員級別:中級無試驗員莊文堂助工崗位證書DB501030試驗員級別:初級無材料員林航助工材料員證BFZ301772材料員級別:初級無合同管理員張功凱會計師職稱證書閩Z012-01394會計師無施工員陳恩施助工施工員證BFZ101681安裝施工員無3.2.3主要管理及技術人員職責說明項目經理項目經理的職責如下:全面負責整個項目執行情況商務合同決策公司人員調配處理與建設單位、監理單位事宜3.2.3.2現場經理現場經理職責如下:實施并全面履行合同,協調與建設單位、監理單位關系;接受建設單位和監理單位監督;協調與各分包的關系,對工程進行總體的協調管理;工程進度,質量和成本進行總體控制;組織工程驗收,交工和結算;負責項目人員組織調配,向辦事處提出人員增減計劃;領導制訂施工計劃,審定各種施工方案;對外重要文件的審定和簽發;考核,評定項目管理人員的業績。系統技術負責工程師系統技術負責工程師直接向項目經理匯報,負責如下:提供工程系統概念可行性分析、系統需求分析和工程計算;為系統需求設計審核提供技術支持;為項目系統調試驗收提供技術支持;領導和監督管理有關隊伍實現安裝計劃,保證在時間計劃內完成合同要求的安裝;按照確定的審核計劃和大綱,進行安裝審核;質保人員一起保證進度審核符合計劃;保證所有區域房間達到良好驗收標準;建立調試計劃;領導和監督管理測試隊伍,按確認的測試協議進行測試;保證項目使用的所有測試、審核和測量設備的準確性和耐久性;維護和保存項目文檔、圖紙和記錄。四、工程計劃進度安排與控制4.1工程進度控制4.1.1工程進度計劃 工程進度計劃嚴格按照甲方的進度要求:合同簽訂后,我單位將嚴格按照施工進度計劃,在60日內保質、保量的完成項目施工。4.1.2項目進度復核項目復核按照項目經理的要求,進行項目執行進度的審核,項目復核將至少包括如下內容:過程和狀態復核;設計變更控制:設計變更是系統實施過程中,難以避免的問題,如何快速簡捷的處理現場設計變更問題,關系到預定工程進度的實現;驗收測試質量控制4.1.3月工程報告月進度報告按以下格式提交給建設單位與監理:重點——報告顯著成績進度和狀態——報告相關項目執行的進度和狀態要預先處理的問題預報——報告下月將要進行的事項每月需維護和更新未完成的工作項目4.2勞動力投入計劃表單位:人工種、級別按工程施工階段投入勞動力情況進場準備管線敷設設備安裝調試消防檢測消防驗收項目經理111111技術負責人111111總工111111電工566665施工員111111試驗員111111安全員111111質檢員111111水暖工210101032雜工333331五.工程施工管理措施5.1質量要求項目經理部針對人防消防改造工程項目所制訂的質量計劃。在質量上要求:(一) 在施工上,工程和系統都應具有高度安全性。(二) 高可靠性。施工的工程、系統在規定的時間內,應使故障率降到最低,避免漏報和誤報,并做到易于維修。(三) 高性能價格比。(四) 安照合同要求,工程項目所用的材料、設備和配件都應選擇質量較高的。廠(商)家有關證明也應齊備。(五) 質量方針:質量第一,信譽至上,精益求精,業主滿意。(六) 質量目標:1、分項工程合格率100%。2、單位工程竣工驗收一次合格率100%。5.1.1質量保證體系項目部保證嚴格按照質量體系的要求,精心組織施工,按期、保質地完成此項消防工程。堅決執行公司的質量方針:質量第一,信譽至上,精益求精,業主滿意。工程質量保證體系見附表:引用標準《質量體系一生產和安裝的質量保證模式》GB/T19002--IS09002:1994中華人民共和國國家標準GBJl6—87《建筑設計防火規范》中華人民共和國國家標準GBJ50116—98《火災自動報警系統設計規范》中華人民共和國國家標準GB50166—2005《火災自動報警系統施工及驗收規范》中華人民共和國國家標準GB50222—95《建筑內部裝修設計防火規范》《自動噴水滅火系統施工及驗收規范》GB50261-96。《自動噴水滅火系統設計規范》GB50084-20015.1.2質量保證具體環節1、機構設置及領導職責工程項目部機構設置:(見附表)領導職責①實施公司質量方針、努力實現質量目標。對所承包工程的質量負全面責任。建立質量保證體系,明確內部質量職能分工;②向總經理負責,對施工進度、工程質量狀況和質量體系文件等進行認真貫徹實施;③加強技術改造,推進技術進步,推廣采用新材料、新技術、新工藝,提高施工隊伍的技術業務素質;④在總工室管理下進行過程、檢驗和試驗、檢驗、試驗狀態、不合格品、糾正和預防措施、包裝、搬運、儲存、防護和交付等控制程序的實施;⑤組織工程投標和合同簽訂,落實施工任務。2、物資采購(1)物資采購主要包括:各種材料、設備和配件的采購。(2)嚴格對廠(商)家的選擇和審核,保證設備及材料的質量。(3)本專業關鍵性設備和材料有:火災報警探測器、消防控制設備、手動火災報警按鈕、消防專用電話、水系統閥門、水系統報警閥組、水系統噴頭,各種鋼管、各種電線。(4) 嚴格檢驗關鍵設備和材料的采購計劃:①項目經理要對廠(商)家進行選擇和評價;②選中的廠(商)家必須提供物資的合格證書、檢測試驗報告;③由項目經理填寫《設備(材料)合同審批表》,交設備部經理審核,報總工程師和總經理審批。(5)對其他相關專業隊伍的設備和材料應提出的消防相關要求:①會發生高溫的設備或燈具附近應使用防火材料或在易燃材料表面涂上防火漆;②220V或以上電壓的電線布線時,應采用暗配線(即穿在建筑結構內預埋的暗管里)。明配線時,應采用明配電線管、電纜橋架、電線槽等保護式配線方法。3、對甲方提供的物資設備:(1) 對于甲方提供的物資,項目負責人要按照相應的合同規定和程序的要求進行驗收。驗收時要注意:①物資的品種和數量是否與有關文件相同;②物資是否滿足有關規范的要求;③物資的檢驗和試驗文件是否齊全。(2)對不合格、損壞及未按發貨單供給的物資,項目負責人要記錄并單獨堆放或加上標記。并按照合同規定的方式書面通知業主代表。項目部作出質量記錄予以保存。(3) 驗收后的物資入庫保管好。5.2文檔管理質量計劃對項目文件控制應規定:(1) 對實施使用的圖紙、技術資料、施工驗收規范、規程、質量檢驗評定標準等的提供和控制;項目質量管理使用的程序文件、工藝標準、操作規程、作業指導書、有關規定等的提供和控制。(2) 規定文件分類:①受控文件;②施工中一般文件;③質量月報記錄。5.3技術管理5.3.1保證工程進度措施1)項目施工前,必須作好施工組織總設計,對勞動力、施工機具、材料需要量等作好充分的準備,才能保證工程進度。如下圖所示,為施工組織總體設計的程序框圖。直觀表明了施工組織設計的各個環節。2)施工人員準備公司的施工隊伍由工程負責人主抓,各管理人員分工負責,形成強有力的領導機構。公司要組織好各種所需勞動力,提高勞動生產率,保證工程質量,組織好現場各項管理工作。3)施工機具與材料準備適應工程的特點,按機具計劃提前購制施工機械和專用工具。為配合超高部位安裝,需加工一部分特制工具箱,以便于班組使用和管理。工長應做好材料計劃,提前做好材料的領用和儲備工作,保證及時供應合格的材料。4)技術準備工作施工人員首先要認真閱讀施工圖紙及有關技術資料,理解設計意圖,制定施工具體方法。為保證工程安裝質量,所有施工人員要認真學習有關施工驗收規范及質量檢驗評定標準和其它一些規章制度。在施工中,技術員要對施工班組進行詳細的技術交底,公司可結合本工程特點,組織進行參觀學習。5)保證工程質量措施施工方面認真貫徹工程質量手冊的執行,做到工程質量分級管理,把好質量關。在竣工驗收時達到一次交驗合格,質量達到優良.加強現場施工質量檢查,配合專業檢查人員做好檢查,對檢查結果不合格的要認真討論分析,制定糾正及預防措施。要嚴格按圖紙施工,對設備要詳細地閱讀說明書和有關資料,要掌握設備的有關規范和技術要求,要編寫施工方案或施工技術措施。加強原材料和設備的進場檢驗工作,做好記錄,堅持不合格品不施工的原則。對相同或類似的設備、管線等安裝,要實行統一做法,首先做好“樣板間”,經驗收合格后,再統一進行安裝施工。對各類專業交叉復雜的部位應預先組織圖紙會審,然后再進行施工,以免造成安裝后的拆改。凡使用新材料、新產品、新技術的項目,應有產品質量標準、鑒定證明書、使用說明及工藝要求等,經甲方同意、批準后方可使用,甲方按其質量標準進行檢查。5.3.1保證工程進度措施施工進度、成本、質量是相互對立統一的整體,在這里我們在控制好成本、保證好質量的前提下提出專門保證進度的一些措施:①現場條件:施工用水、用電的供給到位,消防審批及相關建管部門的開工手續已辦妥,隱蔽工程驗收合格。②施工工人進場作業前,技術人員定期進入現場對照圖紙,認真核實,發現問題及時提出解決。③制定嚴格的施工流程圖和詳細的施工進度表,根據工程量大小及工序安排制定嚴格的現場用工計劃表。④制定詳細的材料供應計劃,保證各類材料根據施工需要,按時保量供應。⑤堅持開碰頭會及周協調會,及時合理調整人力、物力。⑥分項承包責任到人,做到包工、包質、包驗。⑦驗收:對每道完成工序堅持驗收,尤其是隱蔽工程切實做好驗收記錄,防止因上道工序質量原因,造成更大損失。⑧加強“自檢、互檢、交接檢”的三檢制度。各班組密切配合,做好交叉施工作業銜接。5.3.2保證施工安全措施(一) 安全生產措施1、 項目設有專職安全員每周一、四早8:30分到現場進行安全檢查,現場并設有兼職安全員每天不間斷的對現場各項安全進行檢查。項目經理是第一安全責任人。2、 遵守安全規程及施工現場一切管理制度,包括用火制度、暫電制度等。3、 從事高空作業的人員要定期進行體檢。凡患有高血壓病,貧血病,癲癇病以及其它不適于高空作業的,不得從事高空作業。4、 從事無法采取可靠防護措施的高空作業人員,必須使用安全帶,安全帶要栓在牢固的地方,不得掛在帶有剪斷性的物體上。5、 嚴禁穿拖鞋,高根鞋進入施工現場作業。嚴禁酒后作業。6、 不準從各種腳手架上爬上爬下,禁止乘坐吊運大模板,樓板和吊籠等非乘人的垂直運輸設備上下。不準在吊車吊物范圍下行走及停留。7、 作業中禁止投擲物料,清除樓內物料時應設溜槽火使用垃圾桶。手持工具和零星物料應隨手放在工具袋內。8、 不得使用拉頭活動,搖晃的梯子,且必須使用木質梯子;9、 現場行走注意釘子扎腳及鋼筋茬拌腳。10、 剔洞槽時要戴防護鏡,以免灰塊、鑿子毛刺傷眼。11、 作業中禁止互相推打,鬧玩。12、 使用電錘、電鉆、砂輪機等機具,要檢查地線是否完整、接地效果是否可靠,使用電鉆禁止戴手套,使用砂輪機要戴防護眼鏡。13、 現場設有的一級箱、二級箱,接線箱內設有漏電保護開關。14、 使用手持電動工具必須接帶漏電裝置的供電電源。15、 電氣焊及施工用火,要開用火證,清理易燃物,下班后進行檢查。16、 確保安全施工用電,非電氣人員、非暫設電工不得接、拉電線及電氣設備。17、 使用臨時電源,要符合安全用電規定,要用絕緣子固定。線路距地不低于2.5米或在人不易接觸的部位,禁止在路線上搭曬衣服、毛巾,禁止亂拉亂拖導線,以防觸電。18、 潮濕場所,要用安全電壓。19、 電焊機外殼必須接地良好。電焊機要設單獨開關,開關設在防雨的閘箱內,并能上鎖,焊鉗與把線必須絕緣良好,連接牢固,更換焊條應帶手套。潮濕地帶工作,應站在絕緣板或木版上,把線、地線禁止和鋼絲繩接觸,更不得用鋼絲繩或機電設備代替零線,更換場地移動把線時,應切斷電源,并不得手持把線爬梯登高。雷雨時,應停止露天電焊作業。工作完畢應切斷電源并檢查操作地點,確認無起火危險后方可離開。(二) 施焊操作中應注意:1、 氧氣瓶、乙炔發生器和施焊工作點三者互相保持10米以上距離。2、 氧氣瓶要防止暴曬,并嚴禁沾油。3、 乙炔發生器不得存放在高壓線正下方和人流頻繁的路口附近,嚴禁煙火。4、 無合格證者在沒有專人帶領和監護下不得工作。5、 乙炔發生器及皮線在冬季使用應防凍。凍結后只能用熱水或蒸汽解凍。6、 安全膜只能用成品鉛薄膜,不得使用膠皮膜。7、 乙炔發生器必須設有防止回火的安全裝置,保險鏈,它的零件和管接頭不得用紫銅制作。8、 氧氣表及焊割工具上嚴禁沾染油脂。9、 氧氣瓶應有防震膠圈,旋緊安全帽,以免碰撞和劇烈震動。(三) 建全班組安全制度,并設兼職安全員,每周有一次安全活動。(四)施工員要做好季節性安全技術措施,并組織落實。建立完善的安全管理體系:(見附表六)(五) 成品保護措施1、 電氣設備到場后,要放在于燥通風的室內,由專人保管,門窗嚴密,并加鎖。2、 控制元器件,不宜過早安裝,待具備一定的保護條件后再進行安裝,并有經警看守。3、 控制箱柜內的插件,安裝前要取下,保管好,不得隨箱柜一起安裝,以防丟失。4、 電線、電纜敷設完畢后,線槽、線盒應立即加蓋,以防電纜外露丟失。5、 控制中心機房,土建必須門窗裝修完畢后進行設備安裝,機房門應加鎖,重要地方應派人看護。(四) 現場文明施工管理:公司全體人員要嚴格遵守文明施工的原則,積極配合建設單位、總包單位搞好施工現場文明建設,力爭提前按質、按量完成施工。1、嚴禁在施工現場追逐嬉鬧、亂走、亂看、亂寫、亂畫。2、進入現場必須佩帶出入證,穿著必須整齊。3、上、下崗必須統一行動,不得隨意遲到或早退。4、施工現場必須經常保持整潔,材料堆放整齊。5、在施工現場經常進行文明宣傳,時時加強施工人員的文明意識。5.3.3消防保衛措施1、 現場電氣焊,要辦用火證,要持證操作,要有專人看火,要有滅火措施(如消防器具或備水桶)上下班要即時拉閘,閘門設鎖。2、 工具房使用電爐子要辦用火證,接線要安全,閘具要齊全,上下班出去干活都要拉閘。3、 冬季生火爐,要注意煙道暢通。要辦用火證,下班做到真正滅火。并四周澆水,以防著火事故。4、 爐子即電爐旁應清理干凈,保持無易燃燒物,以防火災發生。5、 現場消防器材不許亂動及損壞,不得占用消防交通要道。5.3.4成品及設備部件的保護措施(一) 經除銹、刷油防腐處理后的管材、型鋼、托吊卡等金屬制品應碼放在有防雨措施,運輸暢通的專用場地。(二) 安裝好的管道,不得用做支撐、系安全繩、放腳手板和蹬踩。(三) 搬運管、機具及施焊時,要有具體防護措施,不應臟污、砸壞已經做好的墻面、地面、門窗等。(四) 輕質墻上剔洞作支卡時,必須細心,剔洞要合適,不要將板墻剔裂。(五) 不得在樓板上或抹好的地面上剁管、捻口或制作小工具。(六) 各種端子箱安裝好,應將箱門封好,以免損壞。(七) 套絲機、切管機、電錘等機具設備,用后應當清除雜物、塵土、油垢,以保證其正常運行。5.3.5環境保護措施施工現場文明施工管理必須執行上級頒發的場容管理及有關規定,各施工隊要有一名管理人員主抓,施工員分區負責,各施工班組均有一人負責文明施工。1、施工隊對現場文明施工管理要統一布置,統一安排,每個班組要建立崗位責任制。2、工長施工交底時必須對文明施工提出具體要求,重要部位要有切實可行的具體施工及書面交底。3、操作地點周圍必須做到整潔,干活腳下清,活完料盡,剔鑿、保溫完成后要隨時清理干靜,將廢料倒在指定地點。4、上道工序必須為下道工序積極創造優良的條件,及時做到預留、預埋和暗配工作。5、施工現場堆放的成品、材料要整齊,以免影響地區景觀。5.3.6冬季施工措施(一) 冬季施工措施地下室冬季施工的特點:地下室通風、排煙不暢;用火增多,用電量增多;因此依據以上特點,應采取以下措施:加強對工人和住戶的防火教育,提高防火意識;配備滅火器材;增強易燃、可燃燒材料的管理;檢查地下一層管道保溫,防止水源主管結露、凍結。5.3.7現場文明施工管理(一) 現場文明施工管理:公司全體人員要嚴格遵守文明施工的原則,積極配合建設單位、監理單位搞好施工現場文明建設,力爭提前按質、按量完成施工。1、嚴禁在施工現場追逐嬉鬧、亂走、亂看、亂寫、亂畫。2、進入現場必須佩帶出入證,穿著必須整齊。3、上、下崗必須統一行動,不得隨意遲到或早退。4、施工現場必須經常保持整潔,材料堆放整齊。5、在施工現場經常進行文明宣傳,時時加強施工人員的文明意識六、工程實施6.1工程實施步驟施工過程管理是整個質量計劃的核心部分,通過施工過程管理一系列活動,使圖紙變為實物工程。施工過程管理包括施工進度控制和施工質量控制兩個部分。(1) 施工進度控制對工程總進度計劃和單項(位)工程進度計劃等做出規定。(2) 施工質量控制規定工程實施全過程各階段的施工方法、施工平面圖、各項資源需用量計劃、各項施工準備工作計劃等。主要包括以下階段:①施工準備;②管線及接線箱(盒)施工;③火災探測器安裝;④火災報警控制設備安裝;⑤消防專用通信系統安裝; ⑥自動滅火系統安裝;⑦消防聯動控制系統安裝;⑧火災自動報警系統及聯動功能的調試與試驗;⑨竣工驗收。6.1.1工程實施階段工程施工原則上按照深化設計方案進行,如有個別需要修改之處,必須會同建設單位、監理審定,以設計變更通知單的形式通知乙方。6.1.2糾正和預防措施(1) 不合格的原因調查及分析。對施工全過程、操作、質量記錄、用戶意見進行調查分析,消除不合格工程項目的潛在原因。(2) 糾正措施:①對不合格工程項目進行分類統計,建立質量事故統計臺帳;②提出不合格質量分析報告和糾正措施;③將有效措施標準化,防止不合格的再發生。(3) 執行糾正措施的記錄。6.1.3質量記錄質量記錄是為已完成的活動或達到的結果,提供客觀證據的文件。具體是為質量要求已經滿足的程序和要素運行的有效性提供證據。它的作用是為證實、追溯以及采取預防或糾正措施提供客觀證據。6.1.4檢驗和試驗在工程施工過程中,檢驗和試驗是一項十分復雜而又重要的問題,它涉及面廣,每道工序完工后只有檢驗合格才能轉入下道工序;對進場的材料、構件、設備等也要進行嚴格檢驗、試驗。針對工程項目每項有檢驗、試驗要求項目做出明確規定。主要包括以下內容:(1) 材料、設備進場時,由業主代表、監理和施工單位三方進行驗收。(2) 當分項工程完工后,進行預檢、隱檢、測試和試驗。(3) 當出現不合格品時,必須進行糾正后,再進行復驗,使其符合施工質量和設計要求。(4) 所有預檢、隱檢、測試、試驗記錄等監理或業主代表認可、簽字。七施工機械設備配備7.1機械設備的配置7.2設備操作、保養維修施工建筑機械在使用運行過程中總有一些零部件磨損、變形、松動,當達到一定限度時就影響了機械的精度、性能和完好率,造成環境污染及安全事故,因此必須建立機械設備的維修保養規定。1、必須對設備操作人員進行維修保養重要性的思想教育和技術培訓,掌握機械設備的基本維修知識,執行施工設備管理規定中的有關條款。2、機械設備維修、保養應按其使用說明書進行保養,并有記錄存檔備案。排除漏油、漏水、漏氣、漏電現象。檢查調整各離合器、制動器、安全保護裝置和操作機構等保證靈敏有效。3、檢查各系統有無松動變形、裂紋、發熱、異響、運轉異常等毛病,應及時調整和緊固。4、對所有螺栓等受力大的部位著重檢查,對發現的問題要及時解決。5、進行各類保養作業時,遇到各種故障應予及時排除,不留隱患。6、凡經大修的施工設備都應有記錄,委托有資質修理廠大修的設備出廠時必須有達到產品出廠時工作檢測證明的檢驗合格證。7、機械設備的日常例保要以設備操作人員自行完成,工作前檢查各傳動系統、工作裝置應處于零位、安全裝置靈活有效,潤滑情況等。8、施工作業完成后要對機械設備進行按“十字作業法”,即“清潔、緊固、調整、潤滑和防腐”進行維修保養作業。9、工作現場因突發故障要進行維修時,必須在電閘箱上掛有“嚴禁合閘,正在維修”標志,在操縱臺或操作箱上掛有“正在維修保養禁止開動”標志,非保養、修養人員不準動用機械設備。10、遇有疑難問題,自己解決不了時,應及時向工程技術部匯報加以從速解決,以免影響施工。八、工程施工規范及工藝8.1消防報警、聯動系統部分8.1.1施工工藝流程施工準備預埋檢查線路敷設線路檢查驗收系統試運行系統整體調試設備安裝系統培訓8.1.2施工技術要求(一)施工安裝前的準備1.施工前應確認工程合同的施工內容、范圍等事項。應具備施工的平面圖、安裝圖、系統圖、接線原理圖,以及其它施工必須的技術文件和法律法規,并應加以熟悉和明了。2.依據合同及圖紙的要求勘察施工現場,查閱其它相關專業、工種的圖紙,并進行核對。了解工程的現狀與圖紙要求有否沖突或不符之處,并填寫相應的記錄。3.明確主要材料、設備的采購要求。確定其品種、規格、型號、技術參數,以及生產廠家、資質,服務狀況等詳情。4.明確施工方法、操作順序及工藝要求,明確技術交底及安全交底。入場前應進行施工安全及有關施工現場管理制度、紀律的教育。5.與甲方監理及有關工種等方面進行必要的交流、溝通與配合,并制定施工方案、施工工藝和施工進度計劃。6.對于不明確、有疑問之處,應與相關方面及時聯系,在施工之前妥善解決。7.凡施工機具、工具和儀表儀器,應能滿足施工高峰期的需要。落實其性能、規格、數量,并應進行檢查、檢測,證實其安全有效。8.進場的材料、原料、機具、用具等,必須符合國家或有關部委頒發的現行標準,應附有生產廠家有效的資質證書、檢測報告、材質單、合格證、說明書等,并按要求進行檢查、檢驗、檢測,填寫相應的記錄。9.凡專用的系統設備、系統器材等,進場后應單獨存放保管,不得倒置、傾斜、傾倒,不得受損、受潮,包裝物不得破壞。安裝前應會同生產廠家代表或技術人員共同開箱檢查、檢驗、試驗,簽字移交。并填寫相應的記錄。10.做好施工現場及周邊環境因素、危險源的識別,凡可能發生意外情況的,均應考慮防范措施,并做好應急準備。11.現場施工中,應按照質量控制及過程控制的要求作好各項記錄,做到事事有記錄,步步可追溯。以利一旦發生差錯,便于及時預防糾正,也便于明確責任。(二)布線1.在管內或線槽內的穿線,應在建筑抹灰及地面工程結束后進行。在穿線前,應將管內或線槽內的積水及雜物清除干凈。2.自動報警系統的導線,應采用阻燃銅芯絕緣導線或阻燃銅芯絕緣電纜,其電壓等級不應低于500V。3.火災自動報警系統的傳輸線路的銅芯絕緣導線、銅芯電纜線芯的最小截面面積不應小于下表:序號類別線芯的最小截面面積(mm2)1穿管敷設的絕緣導線1.002線槽內敷設的絕緣導線0.753多芯電纜0.504.導線敷設應便于檢修、更換。盤、箱、柜內的配線應整齊美觀、標志清晰。5.管內敷設絕緣導線截面積≥1.0mm2;線槽內敷設絕緣導線截面積≥0.75mm2;多芯導線截面積≥0.5mm2。6.導線進入端子箱、機箱、設備箱前,宜制作接線圖表,并注明每根導線的編號、走向及功能、用途。7.通常,探測器的信號線‘+’為紅色,‘-’為藍色,其余導線按不同用途應各有區分,線尾應有標識編號。穿線時宜預留適當數量的備用線。8.不同系統、不同電壓等級、不同電流類別的導線不得穿在同一管內,或線槽的同一槽道內。9.在同一建筑物內相同用途的導線,顏色選擇應一致。導線在管內或線槽內不應有接頭或扭結。導線的接頭應在接線盒內,應焊接或用接線端子連接。10.管內導線的總截面積(包括保護層)不得超過管子截面積的40%。11.線槽內導線的總截面積(包括保護層)不得超過線槽截面積的60%。12.系統的導線敷設完畢后,應對每根導線用500V的兆歐表測量絕緣電阻。其任一線間,以及共同對地的絕緣阻值不應小于200MΩ。實測的絕緣電阻值應作記錄。13.各種引入機柜、箱、盤的導線、纜線應符合下列要求:(1)配線整齊、結扎成束、避免絞結、交叉,并卡牢固定;(2)電纜芯線及導線端頭應作標記、編號,標記編號應與圖紙一致,字跡清楚易識,不易褪色;(3)所有端子板上的每個端子,接線不得超過兩根;(4)所有導線在其接線位置應留有適度的余量;(5)電線、電纜引入線管時,線管的進、出口處均應加護口保護;(6)活動地板下敷設的電線、電纜,應采用金屬線槽或金屬軟管保護,不得散亂自由敷放;(7)所有敷設的電線、電纜,其兩端均宜標明編號、用途與功能;(8)導線與部件、端子的連接,宜采用接線叉,接線鉤,接線圈等連接件。并應以專用的壓線鉗壓接。不可用尖嘴鉗、平口鉗等替代,以保證壓接緊密可靠;(9)導線如需直接壓接到部件、端子的接線孔內,則必須‘涮錫’。涮錫時不允許使用腐蝕性助焊劑,應使用松香等助焊;(10)焊接所用的電烙鐵應溫度適宜,烙鐵頭應清潔、吃錫。不允許燙傷導線的絕緣層。14.主機柜、聯動柜、綜合控制臺等消防專用設備,其交流供電的電源,應就近由專用消防電源箱直接引入。不允許使用插頭、插座連接。(三)探測器的安裝1.探測器的安裝應首先安裝底座。應在室內裝修基本完成,較為清潔的條件下進行。2.普通探測器的安裝位置,應符合下列規定:(1)探測器至墻壁、梁邊的水平距離,不應小于0.5m;(2)探測器周圍0.5m內,不應有遮擋物;(3)探測器至空調送風口的水平距離不應小于1.5m;至多孔送風口的水平距離不應小于0.5m;(4)在寬度小于3m的過道、頂棚上設置探測器時,宜居中布置。感溫探測器之間的安裝間距不應超過10m。3.探測器安裝在室內頂棚上時:(1)當頂棚上梁間距離小于1m時,可視為平頂棚;(2)當梁突出頂棚的高度小于200mm時,可以不考慮梁對探測器保護面積的影響。當梁突出頂棚的高度在200~600mm時,應按照規定的圖表確定探測器的安裝位置;(3)當被梁隔斷區域面積,超出一只探測器的保護面積時,則應將被隔斷的區域視為一個需要增加的探測區域,并按有關規定計算需要增加的探測器的數量。4.安裝在頂棚上的探測器,與下列設施邊緣宜保持如下距離:(1)與照明燈具的水平距離不應小于0.2m;(2)距風扇的凈距離不應小于1.5m;(3)距不突出的揚聲器凈距離不應小于0.1m;(4)與噴灑頭的凈距離不應小于0.3m;(5)與多孔送風口的凈距離不小于0.5m,與空調風口的水平距離不小于1m。與防火門、防火卷簾門的距離,一般在1~2m之間的適當位置。5.感煙探測器之間的安裝間距不應超過15m。探測器距墻壁盡頭的距離,不應大于探測器之間距離的一半。6.感溫探測器距高溫燈具(如碘鎢燈、100W以上的白熾燈等)不小于0.5m。7.探測器宜水平安裝,當必須傾斜安裝時,傾斜角不應大于45°。8.在活動頂板上安裝探測器底座時,活動頂板的背面須裝有金屬固定盒(接線盒)。9.在活動地板下安裝時其凈空間大于500mm時,應用支架架起安裝。10.吊頂內安裝探測器,應將固定盒安裝在活動頂板上,再將底座安裝在固定盒上。配線管進入固定盒時要封閉嚴密,避免塵土、蟲、鼠危害。11.探測器的接線頭宜用剝線鉗的適當刃口剝削,不得用刀割、火燒、牙咬,且不得傷及線芯。12.探測器的底座應固定牢靠,其導線連接處必須清潔,并應可靠地壓接。如需涮錫時,不得使用帶腐蝕性的助焊劑。13.探測器底座的端子均有明顯標志。在總線制系統中,信號線的‘+’‘-’接法以一致為妥。14.探測器底座的穿線孔宜封堵,安裝完畢后的探測器底座應做好防護,避免接觸塵埃、涂料等污物。15.探測器的確認燈,應面向便于觀察的主要入口方向。16.安裝總線制探測器時,應核對底座上的編碼是否正確。失靈報廢的探測器不允許隨意丟棄,應交由廠家回收。17.煤氣型可燃氣體探測器宜距地面300mm,天然氣可燃氣體探測器應安裝在頂板上。或參照生產廠家產品說明書的要求安裝。(四)手動報警按鈕的安裝1.報警區域內每個樓層或每個防火分區內,應至少設置一只手動報警按鈕;一個防火區內的任何位置到最鄰近的一個手動報警按鈕的距離不應大于30m。2.手動報警按鈕安裝,應距墻邊、柱體邊緣、門框邊的凈距離不小于200mm。3.手動報警按鈕應安裝在墻上距地(樓)面高度1.3~1.5m處,同一層手動報警按鈕高度應一致。4.手動報警按鈕應安裝牢固,不得松動、傾斜。5.手動報警按鈕的外接導線,應留有不小于10cm的余量,其端部應有明顯標志。(五)聲光報警器、警鈴的安裝1.聲光報警器和警鈴是火災報警系統的燈光、音響報警設備,一般應安裝在門口、走廊和樓梯間等人員經常出入的場所,其燈光、音響應能在樓層或防火分區內任何一處都能看到或聽到。2.聲光報警器應安裝在距地面2.2m處。有吊頂時應安裝在吊頂下0.2m處。3.警鈴,無吊頂時應安裝在距地面1.8m處,有吊頂時應安裝吊頂下0.2m處。(六)端子箱、模塊箱的安裝1.自動報警系統在建筑物內每一樓層或每一分區,應設置專用接線箱。本系統聯動控制的模塊,通常安置在模塊箱內,并應有醒目標志。例如宜用紅色漆料噴涂“消防專用”字樣,以利警示和識別。2.端子箱、模塊箱的安裝位置應按施工圖紙確定,安裝在便于檢查、維修的地方。3.端子箱、模塊箱應采用金屬膨脹螺栓固定在墻上。暗裝時,箱體四周應無空隙,其面板應緊貼墻面。垂直偏差不應大于3mm,箱底邊距地面高度不宜小于1.8m。4.進出端子箱、模塊箱的管路應排列整齊,管路應用管卡固定,不應使端子箱、模塊箱受力過大,箱體的入線孔處應妥善密封,防止灰塵、蟲、鼠進入箱內。5.端子箱、模塊箱的入線孔應光滑,無毛刺,導線的入孔處應設置絕緣膠圈保護。6.端子箱、模塊箱內的端子板應牢固,每個端子不超過兩根導線,并且不受應力。7.端子箱、模塊箱設置在弱電豎井、吊頂內時,必須留有檢查口。8.端子箱、模塊箱內的導線,其功能、數量,應與被控設備的功能數量一一對應,并宜留有備份。信號‘+’、‘-’線,電源‘+’、‘-’線與其它導線應有明顯的標志、能明確地識別。且宜用↑↓箭頭符號表明其走向。9.模塊箱內的各種模塊,各自應有其關于部位、類別、功能、編號等標志,且應與圖紙或設計說明一一對應,如原圖無具體標明,應事前進行編制。10.需要受聯動控制的系統設備,如風機、泵類、電梯、防火卷簾門、非消防用電的強切等,應協調相關專業、工種配合。驗證其獨立功能的有效性。如:啟動、停止,升、降,通、斷等等,是否正常,返回信號的觸點是否良好,有否對地漏電,有否存在短路,并做記錄。無異常時,方可接入相應的模塊。11.總線制系統中,模塊如果具有編碼功能,應正確進行編碼。(七)控制器及聯動設備的安裝連接1.控制器應安裝在消防控制中心或指定的值班室內便于操作和觀察的位置。壁掛式控制器安裝前應按照圖紙或現場環境,確定具體位置鉆孔安裝。如果安裝在支架上,應事先預制支架并進行防腐涂漆。直接落地放置時,應查看機柜四角是否完全著地,必要時用楔子楔緊。2.控制器的周圍應留有適當的空間,以利操作和維修,不可有妨礙操作的障礙物。3.控制器應垂直安裝牢固,不得傾斜。如必須安裝在輕質墻體上時,應采取加固措施。應使用金屬膨脹螺栓固定,不允許使用塑料漲塞。(1)在墻壁上安裝時,其底邊距地(樓)面高度宜為1.5m;(2)落地安裝時,其底部宜設置適當的基座,高出地坪0.1~0.2m;(3)其側面靠近門框的距離不應小于0.5m;(4)集中控制器正面操作距離不應小于1.5m;(5)區域控制器正面操作距離不應小于1.2m;(6)集中控制器雙列布置時正面操作間距不應小于2m;(7)控制器的后蓋板與墻壁的距離不應小于1m;(8)控制器如必須一側靠墻安裝,另一側與墻的距離不應小于1m;(9)控制器重量小于30Kg時,采用膨脹螺栓≥Φ6;(10)控制器重量大于30Kg時,采用膨脹螺栓≥Φ8。4.控制器主電源的入端,應做醒目的標識,并應接入消防專用電源箱,不得接入通常電網。不可使用插頭、插座連接。專用電源箱應有明顯醒目的紅色“消防專用”字樣,以利識別、警示。5.全部線管匯集至中控室后,應先引入總接線箱。總接線箱應有明顯醒目的紅色“消防專用”字樣。6.各部位、各回路、各模塊、各模塊箱的導線,其性能、狀態,均應確認無疑。必要時可再抽測,無誤時方可接入總接線箱。7.進入接線箱的導線,應分機柜(例如:主機柜,1區機柜,2區機柜等)、分類別(如:報警、風機、泵類等)分樓段、分樓層,按照事前編制的接線圖表,壓接于預定的端子排上,并宜加注↓↑走向的符號。再由相應的端子排引出,經由金屬軟管、線槽,引入相應的機柜。8.引入控制器機柜的導線應符合如下要求:(1)確認所有導線正確無誤;(2)配線整齊,結扎成束,不可絞結、交叉,裝卡牢固;(3)導線的尾端應標明編號,且與事前編制的接線圖表一致;(4)每個接線端子不可壓接兩根以上的導線。如超出時,應分散聯通至其余閑置的端子上。9.按廠家編程手冊向各機柜輸入正確的運行程序,并仔細進行核對。10.控制器在特殊條件下工作時(如強磁場、強電場),應有效加強屏蔽保護措施。11.對消防控制室的要求:消防控制室應設在首層主要入口附近出入方便的地方;消防控制室的門應安裝甲級防火門,并向疏散走道方向開啟,且門上方應設置明顯標志;消防控制室應設置外線直撥電話;消防控制室應設置備用應急照明電源;消防控制室的送、回風管在其穿墻處應設防火閥;消防控制室的最小使用面積不宜小于30m2;消防控制室周圍不應布置電磁場干擾較強及其他影響消防控制設備工作的設備用房。(八)系統的接地1.當具備專用接地裝置時,應采用銅芯絕緣導線作為接地線,其截面積應不小于4mm2,接地電阻不大于4Ω。2.當采用聯合接地裝置時,應采用銅芯絕緣導線或銅質編織線連至接地母線。其截面積不小于4mm2,接地電阻應不大于1Ω。3.控制中心備有聯合接地母線時,所有控制設備均應妥善接至該母線上,宜采用總截面不小于4mm2的銅質編織線作為接地導線。4.由控制室引至接地母線的聯線,如需通過墻壁時,應穿入金屬保護管。5.工作接地與保護接地的聯線必須分開,任何接地導體不得以鍍鋅鐵板或金屬軟管代替。8.1.3工程調試驗收(一)自動報警控制系統調試前的準備1.自動報警系統的調試,應在建筑內部裝修完成,其它水電工程完工。無漏水、漏電的條件下,系統施工結束并經監理認定后進行。2.調試負責人必須由有資格的專業技術人員擔任,所有參加調試人員應明確職責,并按照分工有序進行。3.調試前應備有系統圖、布線圖、原理圖、設備使用說明書,系統編程手冊等有關技術資料。4.準備好調試記錄簿、必要的聯絡通訊器材、信號(煙、溫)發生器或生產廠家技術人員認可的代用品等。以及各種型號、規格、數量足夠的備品備件。5.按“規范”的要求檢查系統的施工安裝狀況。對于施工安裝中出現的問題,應會同有關單位協商解決,要有文字記錄。6.系統線路、設備、部件,確認無差錯、無遺漏、無短缺。對于錯線、錯號、開路、短路、錯焊、虛焊以及錯誤“程序”等,必須進行糾正。(二)單機、部件的調試1.分別對區域報警控制器、集中報警控制器、備用電源等,進行初步通電試驗,觀察控制器的儀表、指示燈是否正常,有否異常響動。打開后蓋板,查看有否冒煙情況,有否焦糊異味,有否異常溫升等。確認正常無誤后,可進行下一步。2.控制器通電無誤后,應對下列功能進行檢查:(1)控制器自檢功能:按下自檢按鈕,控制器應能順利通過自檢,然后轉為巡檢狀態;(2)故障報警功能:人為地摘除一只或多只探測器,控制器應能發出持續的故障聲光信號。故障燈閃爍,時鐘停止,顯示首次故障發生的“地址”和時間;(3)火警優先功能:在控制器發出故障報警的狀態下,人為地形成一處或多處火警信號,控制器應能從故障報警的狀態自動轉換為火災報警狀態,火警燈閃爍,時鐘停止,顯示首次火警的發生的“地址”和時間;(4)消音、復位功能:按下消音鈕,報警聲響停止。按下復位按鈕,控制器恢復常態;(5)報警記憶功能:無論故障或火警狀態,控制器均能記憶并顯示首次發生故障或火警的‘地址’和時間。即使故障或火警解除,控制器仍應顯示曾經發生故障或火警的“地址”和時間。直至按下復位按鈕,控制器才恢復常態;(6)主、備電源的自動互投功能:當消防專用電源意外斷電時,控制器應能自動切換到機內蓄電池組繼續工作。當消防專用電源恢復供電時,控制器應能由機內蓄電池組自動切換到消防專用電源繼續工作。如其中某一項失靈,應及時通知廠家維修或更換;(7)電源欠壓、過壓報警功能:正常狀態下,控制器的電源以恒定電壓維持系統正常工作,并對備用蓄電池組充電。如恒定電壓因故超高、蓄電池組電壓超高,控制器將發出“過壓”報警。如恒定電壓低落,或蓄電池組電壓因故跌落,控制器將發出“欠壓”報警。如果此項功能失常,應立即通知廠家維修或更換;(8)打印機:按下打印機的自檢按鈕,打印機應能清晰順利地打印出預置的全部字符。當火警或故障時,打印機應能正確地打印出火警或故障的“地址”和時間,否則不正常。應予調整、維修或更換。3.系統主、備電源的標稱容量應符合設備說明書所注明的數值。4.控制器監控整個系統時,即使發生最大限量的報警情況,其主電源仍應能夠正常工作,不得發生主電系統過熱、跳閘、停頓、死機等異常現象。切換至備電運行40min后,其輸出電壓不得低于22V。如連續3次充放電后,仍不能保證,應由廠家維修或更換。5.分別用主電源和備用電源供電,檢查火災自動報警系統的各項控制功能和聯動功能應該性能一致。6.調試過程中,系統的各項運行功能、故障現象、故障部位、解決途徑、調試日期、時間等,均需在《調試記錄》上詳細記載,并由調試主持人、主要參與者共同簽字。《調試記錄》還應附有控制器當日的打印記錄。7.自動報警系統在連續正常運行120h無故障后,應按本公司規定填寫調試報告,調試報告應有專業技術人員及主要參與者的簽字。(三)系統的聯動調試確認單機、部件及被聯動控制的各專業設備,其獨立功能全部正常后,可進行系統聯動調試。系統聯動調試應由建設主管單位主持,工程監理在場,各施工單位、各專業、各工種等聯合參加,共同進行。1.自動報警:在系統全程范圍內,要求各種報警信號及時準確,所打印的記錄應清晰完整。2.火警事故廣播:應按實際安裝數量全部進行下列功能檢驗:開通緊急廣播擴音機,插入話筒或錄音帶。(1)消防控制室選層廣播:例如:選定開通B層的火警事故廣播,B層及與其上下相鄰的A層、C層,均應能聽到廣播,此外的其它各層都應不能聽到廣播。否則不正常;(2)共用揚聲器系統強切試驗:如果報警系統是與本建筑物內的其它設施共用揚聲器系統(例如某些商場的背景音樂)。當報警系統從巡檢狀態轉入火警狀態時,應能將該共用揚聲器的背景音樂停止,立即轉入火警事故廣播的狀態。否則不正常;(3)備用擴音器切換功能試驗:如果系統內有兩套(或以上)火警事故廣播設備,當其中一套設備突然損壞時,應能夠自動或手動地切換到另一套備用設備上工作。否則不正常。以上試驗,語音應清楚,錄放功效正常,有關現場及控制室的監聽器均應正常收聽。8.2消防噴灑系統部分8.2.1施工工藝流程本工程水噴淋系統管網,根據設計要求,全部采用鍍鋅焊接鋼管,絲扣連結,施工工藝流程如下:安裝準備套絲干管安裝報警閥安裝立管安裝噴淋干支管及水流指示器安裝管道試壓管道沖洗水流指示器安裝及二次安裝報警閥噴淋頭安裝。(1) 施工人員必須經過專業培訓,并有詳細的技術交底。(2) 系統管材及其他所有材料和組件在安裝前必須經過嚴格的檢驗及復查,不合格的產品嚴禁使用。(3) 管道在安裝前必須清除管內的雜物,并注意保持管內清潔,安裝位置必須符合設計要求。(4) 管道連接采用絲扣連接方式時,絲扣質量必須符合有關要求,填料用麻絲鉛油,絲扣不得有超過10%的缺扣或斷絲,外露絲扣在管網試壓驗收后涂刷油漆。(5) 管道支、吊架、防晃支架的制作及安裝必須符合規范要求,當管道改變方向必須設置防晃支架。(6) 管道穿過墻體或樓板時應加設套管,且接縫不得位于套管內,管道穿過變形縫時,應加設柔性管;管道在穿越沉降縫、伸縮縫時應于兩端采用同管徑的橡膠軟接頭連接。(7) 噴淋管支吊架的設置應滿足:a支吊架的設置不得妨礙噴頭的效果;距離應小于300mm;b相鄰兩個噴頭間應至少設置一個吊架,且吊架間距不大于3600mm。C配水支管的第一管段及未梢管段,必須設置吊架。噴淋配水立管、干管及支管上必須設置防晃支架。防晃支間應能承受管道、管子零件、閥門及管內水的總重量及50%水平推力而不損壞或產生永久變形。(8) 管網安裝完畢后,應按標準進行管道沖洗和水壓試驗。(9) 每層噴水支管管網必須有0.002的坡度坡向給水立管。(10)管器連接時,應對機器連接件密封面及密封墊片進行外觀檢查。對口應保持平行,其偏差不大于1.5/1000D(D為管外徑)且小于等于2mm,連接件應保持同軸,其螺栓孔中心偏差小于等于孔徑的5%。法蘭緊固螺栓應對稱均勻,松緊適度。并保證螺栓自由穿入,每個螺栓墊圈不應超過一個。(11)自動噴水滅火系統不同管徑的管道連接,應采用異徑管連接,不得采用補芯。(12)管道閥門的檢驗及安裝要求A、 閥門必須具有合格證明書及標牌B、 從每批閥門中抽查10%(至少一個),進行強度和嚴密性試驗,若有不合格,再抽查20%,如仍有不合格,則需逐個檢查,濕式報警閥閥體必須全部實驗。C、 閥門強度試驗壓力為其公稱壓力的1.5倍,試驗時間大于等于5min,填料無滲漏為合格。D、 閥門試驗作好試驗記錄,并歸入竣工擋案。E、 閥門應在關閉狀態下安裝。F、 所有閥門消防管道管徑<50mm采用截止閥,≥DN50采用優質閘閥或蝶閥。水泵吸水口采用閘閥,管頂平接。水泵出口止回閥采用防水錘消聲止回閥。潛污泵排出管采用閘閥,止回閥采用滑道滾球式排水專用單向閥,市政給水及消防接入管設置防污隔斷器。屋頂水箱出口止回閥采用橡膠瓣逆止閥,閥門壓力等級同各系統管道壓力等級。G、 其法蘭面的連接應符合有關法蘭連接的要求。H、 閥門安裝后,應起閉靈活,指示準確。(13)管道安裝如有間斷時,應及時封閉敞開的管口。(14)噴灑頭安裝必須用專用工具,安裝后濺水盤無歪斜,玻璃球無裂紋和滲漏,噴頭上應無雜物,噴灑頭安裝完畢后,應做試壓滲漏實驗,噴頭安裝前應按全部噴頭的10%按規定壓力進行打壓實驗。(15)管道支吊架的間距應符合設計或規范要求,且間距滿足下表要求:管徑253240507080100125150最大間距3.54.04.55.06.08.08.57.08.0且支、吊架距噴頭不宜小于30cm,距末端噴頭不宜大于75cm。(16)管網安裝完后應按設計或規范要求涂刷紅色標志,支、吊架應涂刷防銹漆。(17)噴頭安裝位置應符合設計及使用要求,噴頭距梁、墻、門、窗、洞口、通風管道、隔斷墻等CFC物的距離應符合規范要求。(18)自動噴水滅火系統A、本工程無吊頂部分采用標準直立型噴頭朝上安裝;其余有吊頂部分采用標準下垂型噴頭朝下安裝,當凈空高度大于800mm的悶頂和技術夾層內有可燃物時應加設標準直立型噴頭朝上安裝。B、自動噴水滅火系統管道的安裝,應為0.02的坡度向放水閥。配水支管至噴頭之間管段的管徑為DN25。C、噴淋消防滅火系統除各泄水閥、末端試水閥為常閉外,其余閥門均為常開閥門,且應有明顯啟閉標志。D、系統末端的試不裝置和試水閥應便于操作,且安裝足夠排水能力的排水設施。E、噴頭安裝應避開燈具,與燈具的水平間距應大于0.3米以上。F、系統安裝做法詳見《自動噴水及水噴霧滅火設施安裝》04S206。(19)報警閥組的安裝應符合規范要求,壓力表安裝位置應宜于觀測,實驗閥、排水閥,控制閥等位置應便于操作,報警閥組組裝后應單獨對閥組進行打壓實驗,不和格的不準使用。(20)法蘭采用絲扣法蘭(21)水流指示器應在管道試壓和沖洗
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 材料加工工藝優化經濟開發合同
- 老妖精造價工程師課件
- 大學近代史考試試題及答案
- 美術說課課件風箏
- 2025年企業安全事故案例分析
- 美術兒童教學課件模板
- 安全評價相關法規
- 機械工程師資格認證考試
- 物流公司司機培訓課件
- 安全檢查活動總結
- 云南省曲靖市宣威市民中2025屆高一化學第二學期期末檢測試題含解析
- 2024年寧夏銀川金鳳區社區專職工作者考試真題
- 新疆天富能源股份有限公司2024年度商譽減值測試資產評估報告
- 2025年黑龍江龍東地區中考數學試卷真題及答案詳解(精校打印)
- 《新青年 鄭出發》打造城市夜經濟文旅美食商業街運營規劃方案
- 普陀區2024-2025學年下學期期末考試六年級數學試卷及答案(上海新教材滬教版)
- 咖啡師考試題庫
- 2025年中國水下測深儀市場調查研究報告
- 2025年陜西省中考數學真題含答案
- 2025年春國家開放大學《馬克思主義基本原理》期末終考試卷1參考答案試卷1
- 2025年供應鏈管理專業考試題及答案
評論
0/150
提交評論