BARTECBARTECGmbH

Schulstra?e30

D-94239

Gotteszell

Telefon

+49(0)9929)-301-0

Telefax+49(0)9929)-301-112

E-Mail:

info@go.bartec.de

Internet:

www.bartec.deHYGROPHIL?

F

5673Operating

manualSoftware

version

1.4BA

080211ContentsC

-

1HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)ContentsContents

PageSystem

description

1-1Measurement

principle,Functionand

applications

1-1Measurement

ofwater

dew

pointtemperature

(Gashumidity)

1-1Layout

ofthe

humidity

measurement

system

1-3Operator

controls

and

display

elements

1-3Keyboard

1-3Key

functions

1-4Display

1-5Interfaces

1-6Technical

data

1-10EvaluationunitF

5673

1-10CPU

plug-inunittype5673-100

1-11Powersupply

plug-inunitDC

24V

type5673-101

1-11Powersupply

plug-inunit

AC

100...240Vtype5673-102

1-11Analogand

digital

I/O

Extype

5673-104

1-12Plug-ininterface

forexternal

touchExtype

5673-105

1-12Plug-ininterfacetype

5673-103

1-12Polychromator

plug-inunit

type

5673-302

1-13Humidity

sensorL1660

1-13Spareparts,accessories

1-15Safety

precautions

2-1Installation

3-1General

3-1Wiring

thesensorL1660

3-1Installing

thesensor

L1660

_3-4Installing

accessories

3-4Assembly

examples

3-4Installation

advice

3-11Operation

4-1Start

up

4-1Calibratingthecoordinatesofthe

touch-screen

4-1Automatic

sensor

equalizing

4-3Display

modes

4-3Combined

display

4-4Selecting

aline

4-4Assigningachannel

4-5Assigninga

measurement

variable

4-5Fixed

values

4-6Status

indication

4-6Graphic

4-6Infoline

4-7Measurementvalue

display

with

sixlines

4-8Measuring

thehumidityinliquids

4-8Online

graphicdisplay

4-9History

graphic

display

4-10History

Setup

4-10Defining

the

presentationperiod

4-10Defining

the

presentationof

thegraph

4-12Displaythehistory

graphic

4-13HideGraphs

4-14Changing

the

display

mode

4-14Issue

date......23.3.3..Contents

C

-

2HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)Contents PageProgramming

5-1General

instructions

5-1Calling

up

programming

mode

5-2Selecting

and

opening

themenu

5-3Editing

parameters

5-4Selecting

the

parameter

setting

5-4Selecting

the

parametersforediting

5-5Numericalentries

5-5Structureofthe

programming

menu

5-6Program

parameters

5-10Dimension

units

5-10Analogoutputs

5-11Analoginputs

5-14Temperature

5-14Pressure

5-15CO2

content

5-15Default

values

5-16Limits

5-17Dateandtime

5-18Serialoutput

5-19Assigninga

liquidtoa

channel

5-20Default

curves

5-21User

specific

curves

5-22EditLiqiuid

Curves

5-22Default

curves

5-22User

specific

curves

5-23Createa

newcurve

5-23Editacurve

5-27Delete

acurve

5-27Offset

5-28Canceloffset

5-29Reset

configuration

to

default

5-30Language

5-30

SystemInformation

5-31ChangePassword

5-32

Maintenance

menu

5-32Error

handling

6-1Limit

transgressions

6-1Warnings

6-2Errors

6-2HELP

key

6-3Maintenance

7-1Cleaning

the

sensor

7-1Appendix

8-1Listofresistanceandsideeffectsforfibre-opticsensorL1660

8-1

Default

liquidcharacteristic

curves

inHYGROPHILF

5673

8-3Certifications

9Issue

date..........146.4789ContentsC

-

3HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)All

rights

reserved

andsubject

tochange.Duplication,

processing

anddistribution

ofthis

document,

including

parts

thereof,

is

prohibitedwithoutthe

prior

writtenconsent

of

BARTEC.Copyright

?

2008

by

BARTEC

Schulstra?e

30,D-94239

GotteszellDocument:BA

080211valid

from:

04.08Revision:Software

version1.421.05.2008Author:G.

RotheTranslation:E.

BauernfeindBARTEC1-1HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)11.1System

description

系統(tǒng)介紹Measurement

principle,

Functionand

applications測量原理、功能、和應(yīng)用HYGROPHILF5673isahigh-quality,microprocessor-controlledfibre-optic

hygrometerformeasuringthemoistureortracehumidityatlowdew-point

temperatures

in

gases

and

liquids.

HYGROPHIL

F

5673

是一款高質(zhì)量,微處理器控制的光纖濕度計(jì),用于測量氣體和液體中的微量水。HYGROPHILF5673worksinmulti-channeloperationwithatemperature-

compensated

fibre-optic

sensordeveloped

especially

formeasuring

the

moisture

content

ingas

mixturesandliquids.HYGROPHIL

F

5673

工作在多通道,帶溫度補(bǔ)償?shù)墓饫w傳感器特別適合測量混合氣體和液體中的水分含量。Measurementofwaterdewpointtemperature

(Gas

humidity)

測量水露點(diǎn)溫度(氣體濕度)The

water

dew

point

is

measured

with

the

HYGROPHIL?

F

and

sensor

type

L1660. HYGROPHIL?

F

用于測量水露點(diǎn),傳感器的型號是

L1660Themoisturesensor,typeL1660,consistsofarobustmulti-layerofoptically

high

and

lowrefractive

layers

connected

to

2fibre-optical

cables.型號為

L1660

的濕度傳感器,由高和低折射率構(gòu)成的多層結(jié)構(gòu),連接到

2

根光纖電纜組成。Duetoaspecialthermalcoatingtechnique,poreswiththediameterofawa-

ter

molecule

(approx.

0,3

nm)

are

generatedon

thelayer.由于特別的熱固化技術(shù),在傳感器表面形成

0.3nm

孔徑。Duetothemoistureequilibriumcontent,waterisdepositedinthelayerand

changes

therefractiveindex

of

the

irradiating

light

(air:

1,00/water1,33).根據(jù)濕度平衡原理,進(jìn)入傳感器的水分子會改變光的折射(空氣

1.00/水1.33)Withinthelayersystemthisresultsinawavelengthshiftinproportiontothe

moisture

prevailing

in

the

medium.

介質(zhì)中的水分含量會引起系統(tǒng)波長成比例的發(fā)生變化。Thisshift

is

measured

by

the

evaluation

unitand

assigned

to

adew

point.電子單元測量到波長的變化并且轉(zhuǎn)換成露點(diǎn)。TheL1660probemakesmeasurementswhicharetemperaturecompen-

sated

(by

the

integratedPt100)

and

pressure

compensated.L1660探頭測量中帶溫度補(bǔ)償(內(nèi)置

PT100)和壓力補(bǔ)償。Inshort,theHYGROPHILF5673worksinconjunctionwithacombination

sensorwhichfibre-opticallydeterminesthemoisturecontentandmeasures

the

temperature

in

the

medium

with

a

Pt100.

總之,HYGROPHIL

F

5673

工作的組合傳感器包括測量濕度含量的光纖和內(nèi)置測量介質(zhì)溫度的

PT100.BARTEC

1-2HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)Apart

from

the

extremely

robust

construction

of

the

sensor,

it

is

above

all

else,the

measurementtechniquewhich

offers

several

decisive

advantages.

除了傳感器具有牢固的結(jié)構(gòu)外,測量技術(shù)還具有幾個(gè)明顯的優(yōu)勢。Some

of

theadvantagesof

this

patentedmeasuring

method

are

asfollows:專利測量技術(shù)的優(yōu)勢體現(xiàn)在以下幾個(gè)方面:High

measuring

confidence,

including

precision,

reproducibility

and

low

hysteresis.

高可靠性,包括精度、重復(fù)性和低滯后。Long-term

stability

of

the

sensor

(no

drift!)

傳感器長期穩(wěn)定(無漂移)Measurement

is

possible

on

the

high-pressure

side(pressure

dew

point!)可以測量高壓下的露點(diǎn)(工況露點(diǎn))Application

in

explosive

areas

(zone

0and

higher)應(yīng)用于防爆場所(zone

0

和更高)Simple

installation

and

upgrading

(Swagelok,

Parker,

…)安裝和升級簡單TheL1660wasdevelopedespeciallyfornaturalgasapplicationsandisnow

appliedintracemoisturemeasurementforalargenumberofdifferentgases

and

liquids.

L1660

特別適合在天然氣中的應(yīng)用,且可以應(yīng)用于多種不同的氣體和液體中微量水的測量。Duetotheusageofhigh-qualitymaterials,thesensorisextremelyrobustand

resistant

to

most

media.

由于探頭選用高品質(zhì)的材質(zhì),傳感器非??煽?,幾乎適應(yīng)于所有的介質(zhì)。BARTEC1-3HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)1.2Layoutofthehumiditymeasure-

ment

system 濕度測量系統(tǒng)的布局The

measurement

system

consists

of

an

evaluation

unit

and

up

to

threehu-

midity

sensors.

測量系統(tǒng)由一臺電子單元和最多

3

個(gè)濕度傳感器組成。The

evaluation

unit

is

designed

as

a

19“rack

which

can

take

several

plug-in

units.The

evaluation

unit

can

also

be

installedas

adesktop

device.電子單元有幾個(gè)插件構(gòu)成

19“機(jī)架。電子單元也可以被安裝成臺式設(shè)備。The

humidity

sensor

consists

of

a

sensor

layer

and

an

integrated

tempera-

ture

sensor,

the

fibre-optic

cable

and

the

plug

connector,

which

also

contains

the

sensor′s

adjustment

data. 濕度傳感器由傳感器層和內(nèi)置的溫度傳感器構(gòu)成,光纖電纜和連接頭,還包括傳感器的標(biāo)定數(shù)據(jù)。The

humidity

sensor

is

available

in

three

standard

dimensions

for

installation

depthsof

0...36

mm,0...100

mm

and

0...225

mm

respectively.濕度傳感器有

3

種標(biāo)準(zhǔn)尺寸的安裝深度

0...36mm,

0...100mm

0...225mmOperator

controls

and

display

ele-

ments 運(yùn)行控制和顯示原理All

operator

controls

and

display

elements

are

at

the

front

side

of

the

evalu

a-

tion

unit.

The

device

is

not

equipped

with

a

mains

switch.

If

shutdown

is

re-quired,

you

have

to

disconnect

the

device

from

the

mains

supply

(mains

plug).

If

operated

as

a

desktop

device,

the

two

front

feet

of

the

evaluationunit

can

beswivelledout

foreasier

operation

and

a

better

viewing

angle.所有的運(yùn)行控制和顯示在電子單元的前部。設(shè)備沒有電源開關(guān),如果需要關(guān)斷,你應(yīng)該從主電源處連接一個(gè)電源開關(guān)。如果是臺式設(shè)備,電子單元的前面有

2

個(gè)腳可以立起來,便于操作和觀察。Keyboard

鍵盤Thedeviceisoperatedviatouch-sensitivekeysonthefrontsideofthede-

vice(numericandmeasurementvariablekeys)andviacertainkeyfunctions

ofthetouch-screen.Allkeysaretouch-sensitive,i.e.youdon’tneedtopress

them,

only

touch

them.

設(shè)備的運(yùn)行是通過設(shè)備前面的觸摸鍵(數(shù)字和測量參數(shù)鍵)和通過觸摸的功能鍵來完成的。所有的鍵都是感應(yīng)的,也就是說,

你不需要按它們,只需要觸摸它們。DisplayKeyboarHYGROPHIL

F

5673,

front

viewF1F2BARTEC

1-4HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)Key

functions

功能鍵Indicationof

the

water

vapour

content[Vol%] 顯示水蒸氣含量Indication

of

the

water

vapour

content

in

parts

per

million

volume

or

in

parts

permillion

weight

PPMV

PPMW

顯示水蒸氣含量Indication

of

thedew-point

temperature

顯示露點(diǎn)溫度Indicationof

the

frost

point 顯示霜點(diǎn)Indicationof

the

watercontent[lb/MMscF]

or[mg/m3]用[lb/MMscF]

[mg/m3]顯示水含量Indication

of

the

water

vapour

partial

pressure

顯示水蒸氣的分壓Selection

of

the

measurementchannel

(see

section

)選擇測量通道(見章節(jié)

)Indication

of

thetemperatureat

themeasuringpoint

顯示測量點(diǎn)的溫度Indication

of

the

pressureatthe

measuringpoint

顯示測量點(diǎn)的壓力Indication

of

thewavelength

顯示波長(1)

In

the

entering

mode

or

programming

mode,

these

keys

serve

to

enter

numerical

values.

在輸入模式或編程模式,這些鍵提供輸入數(shù)字值。Triggerthe

sensor

equalizing(see

section

4.3)

觸發(fā)傳感器自動調(diào)整Call

up

the

history

setup

(see

section

4.4)

進(jìn)入歷史設(shè)置(見章節(jié)

4.4)Switch

from

onlinegraphic

modeto

history

graphic

mode

(see

section

4.4)從當(dāng)前的圖形模式切換到歷史圖形模式(見章節(jié)

4.4)(2)IfthesetwokeysarenotlabelledwithF1andF2onyourmeasuringde-

vice,thisdoesnotmeanthefunctionisrestricted.Thekeyfunctionsare

available

anyhow.Display

ofwarnings

anderror

messages

顯示警告和錯(cuò)誤信息Call

uptheprogramming

mode

(see

section

5.2)進(jìn)入編程模式(見章節(jié)

5.2)Selection

keys

(seesection

5.3),

選擇鍵(見章節(jié)

5.3)Switch

between

the

display

modes

(seesection

4.4)

在顯示模式間切換Change

the

cursorposition

in

entry

fields

(see

section

5.4.3)在輸入?yún)^(qū)域改變光標(biāo)的位置(見章節(jié)

5.4.3)VOL%1PPM2DT3FP4MC5VP-(1)CH16CH27CH38TT9SP0WL,(2)F1F2HELPPROGBARTEC1-5Thefourkeystotherightofthedisplayarenotlabelled.Dependingonthe

operating

status

of

the

measurementsystem,

different

functions

are

as-

signed

to

them.

The

current

function

is

marked

by

a

symbol

next

to

the

key

in

the

display

(forthe

meaningof

thesymbols

seesection5.1).HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)1.3.2Display

顯示A

graphic

display

screen

designed

as

a

touch-screen

is

used

for

display

purposes.

圖形顯示器和觸摸屏設(shè)計(jì)用于顯示Some

functions

are

operated

by

means

of

key

functions

located

on

the

dis-

play

screendependanton

thesituation.BARTEC

1-6HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)1.3.3When

configuring

the

analog

outputs

and

analog

inputs

is

the

designation

of

theclamps

to

beusedshown

inthe

display

(see

sections

5.6.2and

5.6.3).0/4-20mAcurrentoutput

Limit-RelayError-RelayTemperature

sensor

(PT100)Pressuresensor

(4...20mA)CO2

sensor

(4...20

mA)Power

supplyCPUPolychromatorCOMInterfacesChannel

1

Channel

2Channel

3BARTEC1-7HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)BARTEC

1-8HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)BARTEC1-9HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)BARTEC

1-10HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)TechnicaldataEvaluation

unit

F

5673Evaluation

unitDisplay

ranges(defaults)Measurement

variableLower

range

limitUpper

range

limitVol%[%]0100PPM[ppm]025000DT[°C]-100100FP[°C]-100100MC[mg/m3]030000VP[hPa]0250TT[°C]-50100SP[bar]0250WL[nm]780830Auxiliary

variablesThe

temperature

(TT)

at

the

measuring

point

is

measured

via

a

sensor

int

e-gratedinthehumiditysensororenteredbyhand.Thepressure(SP)ismeasuredviaa4...20mAsignalfromanexternalpressuretransmitteror

enteredbyhand.CO2-content(0...100%)ismeasuredviaa0/4...20mA-

signal

orentered

by

hand..Measurement

channelsup

to

3Measuring

rateapprox.

20

measurementsperminute

(per

channel)Inputs

per

measurement

channelLight

waveguideport

for

optical

humidity

sensor9-pole

D-SUB

plugfor

data

memory

withsensor

characteristicClamp-type

terminal

for

PT

100

measurement

sensor

in

sensorheadClamp-typeterminal

for

signalfromapressure

transmitter

(0/4...20

mA)Clamp-typeterminalforsignal0/4...20mA(e.g.CO2content)

allinputs

Ex

ia,

galvanically

separatedAnalog

outputs

per

measurement

channelClamp-typeterminal0/4...20mA,EExia,galvanicallyseparated

SourceandsinkResolution

0,0003

mA

Max.load:500Ω

Accuracy:

0,03

mATemperature

drift:

<0,001

mA/

°CControl

outputs1controloutput

Open

Collector,

EEx

ia,

galvanicallyseparated

Switching

voltage

20...30

V,

switching

currentmax.0,2A

Insulationvoltage

VCM

=1500V

max.1relaychangeovercontact

intrinsicallysafe30V,min.20mA

Connection

viaclamp-type

terminalsInterfacesRS

232,

RS

485DisplayGraphic

display

320

x

240

dotsKeyboardRed

backlit

touch-screenAuxiliary

energyDC10...36Vmax.50W(Si6,3AMT)

AC

100...240V

max.

50

W(Si

4

A

MT)Ambient

conditionsPermissible

workingtemperature:

0...+50°C

Permissiblestoragetemperature:

-25...+60C

Climaticcategory:

IWIaccording

toDIN

40040Dimensions

(WxHxD)483

x

192

x

212Weightapprox.

8,5

kgBARTEC1-11HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)1.4.2CPU

plug-in

unit

type

5673-100Electrical

dataOperating

voltage

ofCPU5,5

V

2

%Power

consumption800

mAFuse

of

battery3,5

AInterface

1USB

2,0

HostOHCI

implementation

12

Mbit

at

fullspeedInterface

2Ethernet100

MBitInterface

3

-7Serial

interfacesUp

to115200

Bit/s,

3,3

V

LVTTLElectronicsProcessorMPC8270

(266

MHz),

Linux

operating

system

Kernel

2.4.25Flash32/64/128

MB

on

board

FlashSDRAM128/256

MB

(CL3)Realtime

clock32,768

kHz

(battery

buffered)Compact

FlashAll

sizesBattery

backupProtects

against

datalossin

caseofunexpected

voltage

breakdownAmbient

conditionsOperating

temperature-

10

+

50

°CStorage

temperature-

20

+

70

°CClimatic

classJWF

in

accordance

with

DIN

40040Protection

typeIP00

in

accordance

with

DIN

400501.4.3Power

supplyplug-in

unitDC

24V

type

5673-101Electrical

dataInput

voltageDC

10...36V,fuse

6,3

A

(MT)Output

voltage5,5V

3,2

Ashort-circuit-proof24

V1,2Ashort-circuit-proof10

V

max.

100

mAMaximum

performance44,8

WAmbient

conditionsOperating

temperature-

10

+

50

°CStorage

temperature-

20

+

70

°C1.4.4Power

supply

plug-in

unit

AC

100...240V

type

5673-102Electrical

dataInput

voltageAC

100...240V,

fuse1

A

(T)Output

voltage5,5V

3,2

A

short-circuit-proof24

V1,2Ashort-circuit-proof10

V

max.

100

mAMaximum

performance44,8

WAmbient

conditionsOperating

temperature-

10

+

50

°CStorage

temperature-

20

+

70

°CBARTEC

1-12HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)1.4.5Analog

and

digitalI/OEx

type

5673-104Electrical

dataOperating

voltage

for

CPUDC

5.5V

2%

200mA

fuse

1

A

(MT)Operating

voltage

for

outputs/inputsDC

24

V

5

%

160

mA

fuse

1.25

A

(MT)Micro-controllerHCS12

16

BitUSB

interface12

Mbit/s

(full

speed)PT-100TypePt-100

4

l

1

mA

-50...+100°CResolution0,005

°C

(16

bit)SeparationGalvanically

separatedAnalog

OutputCurrent

resolution0/4-20

mASeparationGalvanically

separatedSamplingMax.

90

s/sAnalog

InputQuantity2Current0/4...20

mAResolution0,005

mASeparationGalvanicallyseparatedSamplingMax.

100

s/sDigital

Output

OptocouplerVoltage

range20...30

VLoad

currentMax.

0.5

ASeparationGalvanically

separated

VCM

=

1500VUpdate

rateMax.

140/sDigital

Output

RelayVoltageDC

30

VLoad

current10

A

(min.

20

mA)Type1

changeoverAmbient

conditionsOperating

temperature-10…+50

°CStorage

temperature-20…+70

°C1.4.6Plug-in

interface

for

external

touch

Ex

type

5673-105Take

dataof

the

plug-in

interfacefrom

drawingat

page

1-9please.1.4.7Plug-in

interfacetype

5673-103Take

dataof

the

plug-ininterface

from

drawingat

page

1-8

please.BARTEC1-13HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)1.4.8Polychromator

plug-in

unit

type

5673-302Electrical

dataOperating

voltageDC

5.5

VPower

consumption200

mAConnection

typeVGterminal

strip64-pole(bus),

ST

plug

optical

(sensor)InterfaceUSB

12Mbit/s

(full

speed)Measuring

rangeca.

720...870

nmResolution2000

Pixel

0.17nm/PixelAmbient

conditionsOperating

temperature-10…+50

°CStorage

temperature-20…+60

°C1.4.9Humidity

sensor

L1660Thesensorisdesignedwithaporestructuresuitablefortracehumidityap-

plications.Asinglesensorelementcoversthedew-pointrangefrom+20°CDTtoapprox.-80°CDTatdutytemperaturesofupto95°C.Moisturecon-

densationdoesnotimpairthesensor;oncedryitcanbeusedagainwithouthavingtoberecalibrated,i.e.itcanbeusedwithoutdifficultyinmostproc-

esses

subject

to

temporary

condensation.Permissible

working

tempera-

ture-30...+95°C

(sensor

point)Permissible

storage

temperature-30...+50

°CIntegrated

Pt100-50…+100°C,DIN

IEC

751,

4-wire

classAMaximal permissible workingpressure100bar,

200

bar

on

request

with

certificate

(gas-pressure

test)MaterialShaft: 1.4571Sensor

head: POMProtection

typeIP

65

(inbuilt-in

state)DimensionsBARTEC

1-14HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)3020100-10-20-30-40-50-60-70-80-90-100Dew-point

temperature

DT

[°C]-30

-20

-10330 10 20 30 40 50 60 70 80 90

100Gas

temperature

TT

[°C]

Out

ofcalibrated

range

Calibrated

range

Function

range

extrapolatedSensorL

1660,

Dew-point

measuring

range2000010000100010010112PPMV

(at

1013

hPa)BARTEC1-15HYGROPHIL?F5673

Operating

manual,Software

version

1.4,

BA

080211

(2008-5-21)1.5Spare

parts,

accessoriesDesignationTypeSpecificationOrder

No.Evaluation

unit5673-10AC100...240

V Class1/Div.21

channel

installed246

1215673-11AC100...240

V Class1/Div.1inEEx-dcasing

1

channelinstalled242

0575673-12DC

10...36

V Class1/Div.21

channel

installed246

1195673-13DC10...36V Class1/Div.

1

in

EEx-d

casing

1

channelinstalled242

056Accessories

for

evaluation

unit5673-103Plug-in

interface242

0815673-104Channel

extension242

0845673-105Plug-ininterface

forexternal

touch242

0835673-107Wall

holder

/mounting

plate246

120Humidity

sensor

with

integrated

Pt

100Diameter

ofmeasuring

tube

10

mm,

100

bar,

calibratedfrom

80...+

20

°CL

1660Immersion

depth

36

mm221288Immersion

depth

100

mm221227Immersion

depth

225

mm222168Immersion

depth

225

mm

(for

use

with

retraction

tool)275739Specialcalibrationinnaturalgas(withDAPcali-

brationcertificate,calibratedfrom–20...0°DT,at

40

bar)232340Special

calibration

in

hexane

(freely

selectable

measurementrange)232165Special

calibrationin

severalgases

and

liquids

(freely

selectable

measurement

range)239

022Fibre-optic

extension

cable,

field

fitIncluding

ST

plugs

and

adapters1631Length 5

mU01120051631Length 10

mU01120101631Length 20

mU01120201631Length 50

mU01120501631Length 100

mU01121001631Special

lengthsin5

m

steps

up

to100

mSpecial

lengthsin10m

steps,from

100

mup-

wards,

max.length:

800

mU0112xxx1631(xxx

=

length

in

m)Pt100

cable,

field

fit4-wire,

shieldedDeliverable

in

all

lengths232128Fibre-optic

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁內(nèi)容里面會有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫網(wǎng)僅提供信息存儲空間,僅對用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

最新文檔

評論

0/150

提交評論