電氣專業外文翻譯-抗雷擊架空配電線路的可靠性_第1頁
電氣專業外文翻譯-抗雷擊架空配電線路的可靠性_第2頁
電氣專業外文翻譯-抗雷擊架空配電線路的可靠性_第3頁
電氣專業外文翻譯-抗雷擊架空配電線路的可靠性_第4頁
電氣專業外文翻譯-抗雷擊架空配電線路的可靠性_第5頁
已閱讀5頁,還剩8頁未讀 繼續免費閱讀

下載本文檔

版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領

文檔簡介

外文資料翻譯ReliabilityofLightningResistantOverheadDistributionLinesLightingcontinuestobethemajorcauseofoutagesonoverheadpowerdistributionlines.Throughlaboratorytestingandfieldobservationsandmeasurements,thepropertiesofalightningstrokeanditseffectsonelectricaldistributionsystemcomponentsarewell-understoodphenomena.Thispaperpresentsacompilationof32yearsofhistoricalrecordsforoutagecauses,duration,andlocationsforeightdistributionfeedersattheOakRidgeNationalLaboratory(ORNL).Distributiontypelightningarrestersareplacedatdead-endandanglestructuresatpolemountedwormerlocationsandathighpointsontheoverheadline.Stationclasslightningarrestersareusedtoprotectundergroundcableruns,padmountedswitchgearandunitsubstationtransformers.Resistancetoearthofeachpolegroundistypically15ohmsorless.Athigherelevationsinthesystem,resistancetoearthissubstantiallygreaterthan15ohms,especiallyduringthedrysummermonths.Atthesehighpoints,groundrodswererivenandbondedtothepolegroundingsystemsinthe1960'sinanattempttodecreaselightningoutages.Theseattemptswereonlypartiallysuccessfulinloweringtheoutagerate.Fromasurgeprotectionstandpointthevarietyofpolestructuresused(in-line,corner,angle,deadend,etc.)andthevarietyofinsulatorsandhardwareuseddoesnotalloweach13.8kVoverheadlinetobecategorizedwithauniformimpulseflashoverrating(170kV,etc.)oranumericalBILvoltageclass(95kVBIL;etc.).Forsimplicitypurposesintheanalysis,eachoverheadlinewascategorizedwithanominalvoltageconstructionclass(15kV,34kV,or69KV).Sixoftheeightoverheadlines(feeders1through6)werebuiltwithtypicalREAStandardhorizontalwoodcrossarmconstructionutilizingsingleANSIClass55-5porcelainpininsulators(nominal15kVinsulation).Theshieldangleoftheoverheadgroundwiretothephaseconductorsistypically45degrees.Oneoverheadline(feeder7)wasbuiltwithtransmissiontypewoodpoleconstructionbecausethelineextendedtoaresearchfacilitywhichwastohavegeneratedelectricalpowertofeedbackintothegrid.PolestructureofthislineareofdurablewoodcrossaconstructionwhichutilizedoubleANSI52-3porcelainsuspensioninsulatorstosupporttheconductors(nominal34kVinsulation).Theshieldangleoftheoverheadgroundwiretothephaseconductorsforfeeder7istypically30degrees.In1969,anoverheadline(feeder8)wasintentionallybuiltwith"lightningresistant"constructioninanattempttoreducelightningcausedoutages.Polestructuresofthelinehavephaseoverphase24-inchlongfiberglasssuspensionbracketswithdoubleANSI52-3porcelainsuspensioninsulatorstosupporttheconductors(nominal69kVinsulation).Theshieldangleoftheoverheadgroundwiretothephaseconductorsforfeeder8istypically30degrees.Thefailuredatawascompiledforeachoftheeight13.8kVfeedersandispresentedinTable,alongwithpertinentinformationregardingfeederconstruction,elevation,length,andage.Akeyfindingofthefailureanalysisisthatweather-relatedeventsaccountforoverhalf(56%)ofthefeederoutagesrecorded.Fifty-sevenofthe76weather-relatedoutageswereattributedtolightning.Insulationbreakdowndamageduetolightningisalsosuspectedinatleastadozenoftheequipmentfailuresobserved.Thedataindicatesoverheadlineswhichpassoverhighterrainarelessreliablebecauseofthegreaterexposuretolightning.Forexample,feeder3hadthemostrecordedoutages(48),ofwhichtwo-thirdswereduetoweather-relatedevents;thisfeederisalsothehighestlineontheplantsite,risingtoanelevationof450abovethereferencevalleyelevation.Overheadlinesthatarelongerandtowhichmoresubstationsandequipmentareattachedwerealsoobservedtobelessreliable(moreexposuretolightningandmoreequipmenttofail).Theageofthelinedoesnotappeartosignificantlylessenitsreliabilityaslongasadequatemaintenanceisperformed;noneofthelineshavehadanotableincreaseinthefrequencyofoutagesasthelineshaveaged.Aswouldbeexpected,theempiricaldatapresentedinTableIconfirmsthetwooverheadlineswhichhavebeeninsulatedtoahigherlevel(34or69KV)havesignificantlybetterreliabilityrecordsthanthoseutilizing15kVclassconstruction.Feeder7(insulatedto34KV)andfeeder8(insulatedto69kV)havebadonly3outageseachovertheir32and23yearlifespans,respectively.Theselinesfollowsimilarterrainandarecomparableinlengthandagetothe15kVclasslines,yettheyhaveacombinedfailurerateof0.22failuresperyearversus4.32failuresperyearfortheremainingfeeders.Ontypical15kVinsulatedlineconstruction,lightningflashoversoftencause60cyclepowerfollowandfeedertrip.Withthehigherinsulationconstruction,outageratesarereducedbylimitingthenumberofflashoversandtheresultantpowerfollowwhichcausesanovercurrentdevicetotrip.Thisallowslightningarresterstoperformtheirdutyofdissipatinglightningenergytoearth.Thenumberofrecloseractionsandtheirresultantmomentaryoutagesarealsoreduced.Thisisbeneficialforcriticalfacilitiesandprocesseswhichcannottolerateevenmomentaryoutages.Anadditionalbenefitisthatoutagesduetoanimalcontactarealsoreducedbecauseofthegreaterdistancefromphaseconductortogroundonpolestructures.Distributionlineequipmenttoincreaselineinsulationvaluesare"offtheshelf"itemsandproventechnology.Newlightningresistantconstructiontypicalbyutilizeshorizontallineposts,fiberglassstandoffbracketsoranyothermethodwhichworldincreasetheinsulationvalue.Thereplacementofstandardpininsulatorswithlinepostinsulatorsofgreaterflashovervalueisaneffectivemeanstoretrofitexistingwoodcrossarmconstruction.Thedoublingandtriplingofdeadendandsuspensioninsulatorsisalsoameansofincreasingflashovervaluesonexistingangleanddead-endstructures.Currentfiberglass,polymer,andepoxytechnologiesprovideanaffordablemeanstoincreaselineinsulation.Whiletheuseofincreasedinsulationlevelstoreducelightningflashoversandtheresultantoutagesonoverheaddistributionlineshasbeenthoroughlytestedanddemonstratedinlaboratoryandexperimentaltests[5],longtermhistoryfielddatahaspositivelydemonstratedthattheuseof"lightningresistant"constructioncangreatlyreduceoutages.FielduseatORNLhasshownthatinareaswhicharevulnerabletolightning,theuseofincreasedinsulationandasmallershieldingangleisanimpressiveandcosteffectivemeanstoappreciablyincreasethereliabilityofoverheaddistributionlines.Thisreliabilitystudyclearlyillustratesthattheinsulationrequirementsforhigh-reliabilitydistributionfeedersshouldbedeterminednotbythe60Hzoperatingvoltagebutratherbywithstandrequirementsforthelightningtransientsorotherhighvoltagetransientsthatareimpressedupontheline.Electricalequipment(switchgear,insulators,transformers,cables,etc.)haveareserve(BElevelorflashovervalue)tohandlemomentaryovervoltages,andbyincreasingthatreserve,theservicereliabilityisappreciablyincreased.Astheelectricalindustrygraduallymovesawayfromstandardwoodcrossarmconstructionandmovestowardmorefiberglass,polymerandepoxyconstruction,increasedinsulationmethodscanbeappliedaspartofnewconstructionoraspartofanupgradeorreplacementeffort.Inconsideringneworupgradedoverheadlineconstruction,theincrementalincreasedcostofthehigherinsulationequipmentisdinproportiontothetotalcostsofconstruction(labor,capitalequipment,cables,electricpoles,right-of-wayacquisition),Itscosteffectivenessvarieswiththeapplicationandtheconditionstowhichitisbeapplied.Economicbenefitsincludeincreasedelectricalservicereliabilityanditsinherentabilitytokeepmanufacturingprocessesandcriticalloadsinservice.Othermoredirectbenefitsincludelessrepairofoverheaddistributionlines,whichcanhaveasignificantreductioninmaintenancecostduetolessreplacementmaterialsandalargereductioninovertimehoursformaintenancecrews.抗雷擊架空配電線路的可靠性閃電仍然是架空配電線路上的中斷1的主要原因。通過實驗室測試和現場觀察和測量,雷擊和其對配電系統組件的屬性是很好理解的現象。本文提出了一個32年的歷史記錄,停運的原因,時間,地點,在橡樹嶺國家實驗室的八個配電饋線匯編。配電型避雷器在死胡同和角度的結構被放置在極安裝W奧莫爾的位置,并在高點上的架空線。站級避雷器是用來保護地下電纜運行,墊置式開關柜,單位變電站變壓器。每個極接地的接地電阻通常是15歐姆或更小。在高海拔系統中,基本上是對地電阻大于15歐姆,尤其是在干燥的夏季。在這些高點,研磨棒極接地系統,在1960年,企圖以減少雷擊停電驅動和保稅。這些嘗試只是部分成功地降低停電率。從浪涌保護的角度來看,使用各種不同的桿件結構(列直插式,角,角,死路,等),和絕緣體及使用的硬件的各種不允許每13.8千伏架空線具有均勻的沖擊閃絡分類評價(170千伏,等)或一個數值的的BIL電壓類(95千伏BIL,等等)。在分析中為了簡單起見,每個分類的額定電壓建筑類(15千伏,34千伏,69千伏)架空線。六七八個架空線(饋線1至6)建立典型的REA標準水平木橫擔,利用單級的ANSI55-5瓷針式絕緣子(標稱15千伏絕緣)。架空地線相導線的屏蔽角通常是45度。一架空線(饋線7)建延長線傳輸型木桿建設,因為這是已產生的電能反饋到電網的研究設施。這條線極結構耐久的建設的其中利用雙ANSI52-3瓷懸式絕緣子支持(標稱34千伏絕緣)。饋線7的架空地線的相導體的屏蔽角通常是30度。在1969年,架空線(饋線8)有意建立“抗雷擊”試圖減少雷電造成的停電。該行的極結構階段階段超過24英寸長的玻璃纖維懸掛支架與雙ANSI52-3瓷懸式絕緣子,支持標稱69千伏絕緣的導體。饋線8架空地線的相導體的屏蔽角通常是30度。編制各八個13.8千伏饋線故障數據列于表I中,沿饋線結構,海拔高度,長度,和年齡的相關信息。故障分析的一個重要發現是,與天氣有關的事件占了一半以上(56%)的饋線停電記錄。五十七名76天氣有關的中斷是由于雷擊。絕緣擊穿損壞,由于雷擊還涉嫌至少有十幾觀察到的設備故障。數據表明架空線路經過地勢高,是不可靠的,因為雷擊風險更大。例如,饋線3最錄制中斷(48),其中三分之二是由于與天氣有關的事件,這也是最高的饋線線廠區,上升到海拔450英尺以上的參考山谷高度。也觀察到架空線更長,更多的變電站和設備連接不可靠(多接觸雷擊和更多的設備失敗)。行的年齡似乎并不顯著減輕其只要足夠的維護;線中斷的頻率有一個顯著的增加作為線路歲。正如所預料的,實證的數據列于表我確認兩架空線路絕緣已到一個更高的水平(34或69千伏),有顯著更好的可靠性記錄比那些利用15千伏級建設。饋線7(絕緣的34千伏)和饋線8(絕緣的69千伏)每過32年和23年的壽命只有3停電有壞。下面的幾行類似的地形,在15千伏級線路長度和年齡相媲美,但他們有一個合并的失敗率每年0.22次失敗與4.32每年剩余的饋線故障。在典型的15千伏絕緣線建設,雷電閃絡往往造成60循環發電后續和饋線跳閘。具有較高的絕緣結構,減少停機率次數限制的閃絡,這會導致過電流跳閘的移動設備以所得的功率后續。這使避雷器雷電能量耗散地球履行撫養義務。重新接近的行動和其產生的瞬間中斷的數量也減少了。這有利于對關鍵設備和工藝無法容忍甚至瞬間停電。另外一個好處是,由于動物接觸的停電也減少了,因為更大的距離從相導線接地極結構。配電線路設備,以提高線路的絕緣值是“現成的”項目和成熟的技術。新抗雷擊建設典型的利用水平線職位,玻纖對峙括號或任何其他方法,增加保溫值世界。更換標準針式絕緣子線路柱式絕緣子閃絡值更是一種有效的手段來改造現有的木材橫擔建設。增加一倍和兩倍死路一條懸式絕緣子閃絡值增加現有的角度和死胡同結構的一種手段。電流的玻璃纖維,聚合物,和環氧技術提供價格合理的手段,以提高線路的絕緣。雷擊閃絡,以及由此產生的架空配電線路停電,雖然使用的絕緣水平增加已徹底測試,在實驗室和實驗測試證明,長期歷史的現場數據,積極表明,使用“抗雷擊”可大大減輕施工中斷。在橡樹嶺國家實驗室的現場使用表現出易受雷電領域,使用增加的絕緣和一個較小的遮光角是一個令人印象深刻的和成本有效的手段架空配電線路的可靠性明顯增加。這種可靠性研究清楚地表明,絕緣要求高可靠性的配電饋線應確定,而不是由60赫茲工作電壓,而是承受雷電瞬變要求或其他高電壓瞬變行后留下了深刻的印象。電氣設備(開關,絕緣子,變壓器,電纜等)儲備(水平或閃絡值)來處理瞬時過電壓,并通過增加儲備,服務的可靠性明顯提高。由于電器行業逐漸移開木橫擔從標準建設和走向更多的玻璃纖維,聚合物和環氧樹脂建設,增加??保溫方法可用于新建筑的一部分,或作為升級或更換努力的一部分。在考慮新的或升級的架空線路施工,更高的絕緣設備的增量成本增加比例為的總建設成本(電纜,電線桿,偏右的方式收購),它的成本效益變化與該應用程序和條件是它是被應用。經濟效益包括增加電力服務的可靠性和其固有的能力,以保持制造工藝和關鍵負載的服務。其他更直接的好處包括架空配電線路較少的維修,它可以有一個顯著減少維護成本較少的替代材料,并大量減少維修人員的加班時間。

本科生學位論文論多媒體技術在教學中的應用姓名:指導教師:專業:教育管理專業年級:完成時間:

論多媒體技術在教學中的應用[摘要]多媒體不再是傳統的輔助教學工具,而是為構造一種新的網絡教學環境創造了條件,特別是對于教育社會化來說,多媒體網絡是一種更理想的傳播工具。多媒體本身具有:融合性、非線性化,無結構性、相互交涉性、可編輯性、實時性等特點;同時運用在教育教學上又有其特長:利于信息的存儲利用、是培養發散性思維的工具、促使學習個別化的實現。多媒體在教學中的應用有著多種的形式,它在提高學生學習興趣上有著積極的作用,同時它還能促進學生知識的獲取與保持、對教學信息進行有效的組織與管理、建構理想的學習環境,促進學生自主學習等多方面的效果。立足未來發展,利用多媒體網絡技術,開展教學試驗。[關鍵詞]多媒體網絡教學系統資源共享多媒體技術主要指多媒體計算機技術,加工、控制、編輯、變換,還可以查詢、檢索。人們借助于多媒體技術可以自然貼切地表達、傳播、處理各種視聽信息,并具有更多的參與性和創造性。當今多媒體已成為廣泛流傳的名詞,但人們對于它的認識,特別是對于它在教育教學方面如何更好應用,未知的因素還很多。

一、多媒體的教育特長任何一種媒體不管其怎樣先進,它只能是作為一種工具被應用到教育領域,能不能促進教育的改革,。。。。。。應當吸取教訓,加強理論研究,充分認識多媒體的特性及其教育特長,以便更好地在教育領域開發應用多媒體。

1、多媒體的特性

(1)融合性多種符號系統的融合是多媒體的特性之一,多媒體的這一特性區別于過去媒體符號系統的單一性或復合性。也就是說多媒體技術不是將符號系統疊加,而是具有整體性的融合。

(2)非線性化,無結構性因為多媒體是在超文本、,其組合結構是固定的、不變的。

(5)實時性多媒體信息中的聲音、活動視瀕、動畫于時間

溫馨提示

  • 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
  • 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
  • 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
  • 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
  • 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。

評論

0/150

提交評論