版權說明:本文檔由用戶提供并上傳,收益歸屬內容提供方,若內容存在侵權,請進行舉報或認領
文檔簡介
ICS27.010
CCSP46
團體標準
T/CECA-G00XX—202X
戶式空氣源熱泵三聯供系統技術規范
Technicalspecificationforcooling,heatingandhotwaterbyair-sourceheatpump
system
(征求意見稿)
202X-XX-XX發布202X-XX-XX實施
中國節能協會發布
T/CECA-G00XX—202X
目??次
前??言.............................................................................................................................................................III
1范圍................................................................................................................................................................1
2規范性引用文件...........................................................................................................................................1
3術語和定義...................................................................................................................................................1
4設計參數及計算...........................................................................................................................................2
4.1一般規定....................................................................................................................................................2
4.2冷負荷計算................................................................................................................................................2
4.3熱負荷計算................................................................................................................................................3
4.4新風負荷計算............................................................................................................................................3
4.5生活熱水負荷計算....................................................................................................................................4
5系統設計.......................................................................................................................................................4
5.1一般規定....................................................................................................................................................4
5.2系統要求....................................................................................................................................................5
5.3輸配系統....................................................................................................................................................6
5.4冷熱水管路系統........................................................................................................................................6
5.5水泵............................................................................................................................................................7
5.6水箱............................................................................................................................................................9
6末端設計.......................................................................................................................................................9
6.1一般規定....................................................................................................................................................9
6.2風機盤管....................................................................................................................................................9
6.3地暖............................................................................................................................................................9
7電氣系統與智能控制.................................................................................................................................10
7.1一般規定..................................................................................................................................................10
7.2系統集成控制器......................................................................................................................................10
7.3房間溫度控制器、室內溫濕度傳感器、室外溫度傳感器..................................................................10
7.4配電系統..................................................................................................................................................11
7.5控制與監測..............................................................................................................................................11
7.6安全防護..................................................................................................................................................11
8安裝施工與調試驗收.................................................................................................................................11
8.1一般規定..................................................................................................................................................11
8.2施工準備..................................................................................................................................................12
8.3主設備安裝..............................................................................................................................................12
8.4末端設備安裝..........................................................................................................................................12
8.5輸配管路及輔件安裝..............................................................................................................................12
8.6管道系統沖洗、試壓..............................................................................................................................13
8.7管道絕熱..................................................................................................................................................13
8.8電氣系統安裝..........................................................................................................................................13
8.9調試與驗收..............................................................................................................................................14
附錄A(資料性)間歇供冷民用建筑單位面積冷負荷概算值.........................................................17
I
T/CECA-G00XX—202X
附錄B(資料性)戶式三聯供系統示意圖.........................................................................................18
II
T/CECA-G00XX—202X
前??言
本文件按照GB/T1.1—2020《標準化工作導則第1部分:標準化文件的結構和起草規則》的規定起
草。
請注意本文件的某些內容可能涉及專利。本文件的發布機構不承擔識別專利的責任。
本文件由中國節能協會提出并歸口。
本文件由中國節能協會熱泵專業委員會負責組織起草。
本文件起草單位:造夢者(浙江)科技有限公司、××××、××××等。
本文件主要起草人:。
III
T/CECA-G00XX—202X
戶式空氣源熱泵三聯供系統技術規范
1范圍
本文件規定了戶式空氣源熱泵三聯供系統(以下簡稱戶式三聯供系統)的設計、施工、系統調試與
驗收。
本標準適用于單臺機組名義制熱量不大于100kW,以空氣源熱泵三聯供機組與同等數量的承壓式儲
能水箱及承壓式換熱熱水水箱組合而成的冷暖兩聯供加熱水系統。
2規范性引用文件
下列文件中的內容通過文中的規范性引用而構成本文件必不可少的條款。其中,注日期的引用文件,
僅該日期對應的版本適用于本文件;不注日期的引用文件,其最新版本(包括所有的修改單)適用于本
文件。
GB/T9237制冷系統及熱泵安全與環境要求
GB50015-2019建筑給水排水設計標準
GB50057建筑物防雷設計規范
GB50242建筑給水排水及采暖工程施工質量驗收規范
GB50254電氣裝置安裝工程低壓電器施工及驗收規范
GB50303建筑電氣工程施工質量驗收規范
GB50411建筑節能工程施工質量驗收標準
GB50736民用建筑供暖通風與空氣調節設計規范
GB50738通風與空調工程施工規范
JGJ142輻射供暖供冷技術規程
JGJ242住宅建筑電氣設計規范
RISN-TG039-2021戶式空氣源熱泵冷暖兩聯供工程技術導則
T/CECA-G0094-2020商業或工業用及類似用途的熱泵熱水集成系統設計、安裝與驗收規范
3術語和定義
T/CECA-G0094-2020界定的以及下列術語和定義適用于本文件。
3.1
空氣源熱泵三聯供機組cooling,heatingandhotwaterbyair-sourceheatpumpsystem
以空氣為冷、熱源,采用電動機驅動的蒸氣壓縮制冷循環,既能在夏季制取空調用冷水和生活熱水,
也能在冬季制取供暖用熱水和生活熱水的熱泵機組。
3.2
承壓式儲能水箱pressureenergystoragehotwatertank
模塊承壓系統中,與空氣源熱泵機組循環加熱的承壓式水箱。
3.3
1
T/CECA-G00XX—202X
承壓式換熱熱水水箱pressurethermalexchanginghotwatertank
模塊承壓系統中,負責貯存熱水內置盤管換熱的承壓式水箱。
3.4
換季三通閥Seasonalthree-wayvalve
系統中,在水箱一二次測,為提高制冷、熱效率,用于供回水口切換的閥門裝置。
3.5
一次泵系統primarywaterpumpingdistributionsystem
冷熱源側和負荷側共用一個循環泵組的水系統。
3.6
二次泵系統secondarywaterpumpingdistributionsystem
冷熱源側和負荷側分為兩個環路,并單獨配置循環泵組的水系統。
4設計參數及計算
4.1一般規定
4.1.1人員長期逗留區域室內設計參數應符合表1的規定。
表1人員長期逗留區域室內設計參數
溫度相對濕度風速
參數熱舒適度等級
℃%m/s
I級22~24≥30≤0.2
供熱工況
II級18~22—≤0.2
I級24~2640~60≤0.25
供冷工況
II級26~28≤70≤0.3
注1:I級熱舒適度較高,II級熱舒適度一般。
注2:熱舒適度等級劃分見4.1.3。
4.1.2人員短期逗留區域室內設計參數的供冷工況溫度宜比人員長期逗留區域高1℃~2℃,供熱
工況溫度宜比人員長期逗留區域低1℃~2℃,供冷工況的風速宜不大于0.5m/s,供熱工況的風速宜
不大于0.3m/s。
4.1.3供暖與空調室內熱舒適性應按GB/T18049的有關規定執行,熱舒適度等級應按表2劃分。
表2熱舒適度等級
熱舒適度等級PMVPPD
I級-0.5≤PMV≤0.510%
II級-1≤PMV<-0.5,0.5<PMV≤127%
注:PMV為預計平均熱感覺指數,PPD為預計不滿意者的百分數。
4.2冷負荷計算
4.2.1戶式三聯供系統冷負荷計算應符合GB50736的規定,宜采用專業軟件進行計算。
2
T/CECA-G00XX—202X
4.2.2按各房間冷負荷選用末端設備。間歇使用戶式三聯供系統的房間,間歇系數應選取1.5~2.0。
4.2.3按戶內總冷負荷選用冷熱源設備。戶內總冷負荷應按下列情況確定:
a)當系統設有自控時,將同時使用的各個房間逐時冷負荷累加,得出建筑物冷負荷的逐時值,取
其中的最大值;
b)當基礎數據不全時,可將各房間冷負荷按公式(1)進行概算后累加:
式中:
?L=?L×?×?#……1
QL——冷負荷,單位為瓦(W);
2
qL——單位面積冷負荷概算值,單位為瓦每平方米(W/m),見附錄A;
S——供冷區域面積,單位為平方米(m2);
A——同時使用系數,當所有房間的空調需同時使用時取1.0,當無法確定同時使用的各房
間時取0.5~0.7。
4.2.4若設置新風系統,產生的新風冷負荷應計入戶內總冷負荷,按4.4計算。
4.2.5戶內總冷負荷應考慮風機、風管、水泵、管道和水箱溫升導致的附加冷負荷。
4.3熱負荷計算
4.3.1戶式三聯供系統熱負荷計算應符合GB50736的規定,宜采用專業軟件進行計算。
4.3.2民用建筑的戶內供暖總熱負荷應包含:
a)外圍護結構的傳熱耗熱量;
b)由外門、窗縫隙滲入室內的冷空氣耗熱量;
c)當外門開啟時經外門進入室內的冷空氣耗熱量;
d)戶間傳熱量。
4.3.3結合開機率等確定冬季間歇供暖戶內供暖總熱負荷,宜為冬季連續供暖戶內供暖總熱負荷的
1.05倍~1.20倍。
4.3.4若設置新風系統,產生的新風負荷應計入戶內供暖總熱負荷,按4.4計算。
4.3.5輻射面的傳熱量計算應符合JGJ142的有關規定。
4.4新風負荷計算
4.4.1采用戶式三聯供系統的建筑,其新風補充方式主要有:
a)門、窗的自然滲透;
b)新風未經處理,由小型風機直接送風;
c)新風經新風空氣處理機組處理后送入室內;
d)新風經熱回收裝置處理后送入室內。
4.4.2新風負荷的計算應符合下列規定。
a)新風未經處理直接進入室內,其負荷全部由房間末端設備負擔時,新風負荷按公式(2)計算:
式中:
??=0.28×?v×?a×|?w??n|………………2
Qf——新風負荷,單位為瓦(W);
3
qv——新風量,單位為立方米每小時(m/h);
3
ρa——新風密度,單位為千克每立方米(kg/m);
hw——室外計算參數的比焓,單位為千焦每千克(kJ/kg);
hn——室內計算參數的比焓,單位為千焦每千克(kJ/kg)。
3
T/CECA-G00XX—202X
b)當新風經新風空氣處理機組處理到室內空氣等焓值時,新風負荷全部由新風空氣處理機組負擔,
房間末端設備不負擔新風負荷;當沒有處理到室內空氣等焓值,還需要房間末端設備進一步處
理至室內空氣狀態焓值時,這部分新風負荷由房間末端設備負擔,可按公式(2)計算,此時
室外計算參數的比焓按新風空氣處理機組后的新風焓值。
c)新風經熱回收裝置處理后,一般達不到室內空氣狀態等焓值。這部分新風送入房間,并通過專
門的新風空氣處理機組處理時,新風負荷由該空氣處理機組負擔;未設置新風空氣處理機組時,
新風負荷由房間末端設備負擔;可按公式(2)計算,此時室外計算參數的比焓按熱回收裝置
后新風焓值。
4.5生活熱水負荷計算
4.5.1空氣源熱泵三聯供機組產水量應滿足GB/T23137-2020相關規定。
4.5.2空氣源熱泵三聯供機組產水能力按下列規定:
a)當使用承壓式換熱熱水水箱時,給水定額流量應綜合考慮衛生器具的同時使用系數,滿足不
低于各衛生器具同時使用流量之和,設計水箱所需換熱量按公式(3)計算:
T………………(3)
式中:
?i= 主站蜘蛛池模板: 旬阳县| 铅山县| 屯门区| 开鲁县| 长汀县| 凤山市| 济阳县| 城市| 河池市| 鲁山县| 平顺县| 宜良县| 宿迁市| 金昌市| 奈曼旗| 长宁区| 兴文县| 盐山县| 淳安县| 黄山市| 四会市| 綦江县| 康马县| 长白| 阿尔山市| 米易县| 安龙县| 施甸县| 钟山县| 万安县| 深水埗区| 阜康市| 潞西市| 阜阳市| 红桥区| 桦川县| 连山| 商南县| 宜阳县| 嘉善县| 香格里拉县|