1、某高校學生公寓設計(3) 摘要:本工程學生公寓位于成都市某大學內,其功能是為學校學生提供住所。該工程為多層現澆鋼筋混凝土框架結構,共五層,底層層高3.3米,其他層層高均為3.3米,建筑物總高度為18.5米,總建筑面積為4022.15平方米。4人間設計,有獨立的衛生間和陽臺,能滿足四百多人同時入住。關鍵詞: 鋼筋混凝土, 框架, 結構設計 the design of students apartment of an university abstract:this is a students dormitory of a middle school in the xian newly devel
2、oped area. its function is provides the residence for the school student. it is a multi-layer reinforced concrete frame. it has five stories, the height of the first storey is 3.3 meters, and the height of other stories are all 3.3 meters. the height of the whole building is 18.5 meters. the total f
3、loor space is 4022.15 square meters. one room can live four students, has the independence the bathroom and the balcony. altogether can live 440 people.keywords :reinforced concrete, frame, the design of the structure目 錄1.設計原始資料及條件12.建筑初步設計說明書 12.1工程設計依據1 2.1.1成都大學本科畢業設計(論文)任務書1 2.1.2本畢業設計(論文)所遵循的主要
4、規范和規程12.2工程概況12.3設計特點22.4防火與疏散設計2 2.4.1防火設計2 2.4.2疏散設計22.4土方工程22.5墻體工程22.6樓地面22.7門窗32.8建筑節能32.9其他33.結構計算書3 3.1工程概況3 3.2設計依據3 3.3圖紙說明4 3.4建筑分類等級4 3.5主要荷載(作用)取值4 3.6設計建設程序4 3.7主要結構材料43.7.1混凝土43.7.2鋼筋43.7.3砌體4 3.8樓蓋設計43.8.1樓面做法43.8.2樓面荷載43.8.3材料43.8.4樓蓋的結構平面布圖43.8.5截面設計53.8.6次梁的設計5 3.9恒荷載計算63.9.1屋面框架梁線
5、荷載標準值 63.9.2樓面框架梁線荷載標準值63.9.3屋面框架節點集中荷載標準值73.9.4樓面框架節點集中荷載標準值73.10樓梯設計 7 3.10.1 梯斷板7 3.10.2平臺板8 3.10.3平臺梁8 3.11基礎設計83.11.1基礎臺階的寬高比和偏心距控制83.11.2 獨立基礎的最小配筋率 83.11.3 柱縱向受力筋的插筋在基礎內的錨固長度 83.11.4獨立柱基間拉梁 83.11.5 多層鋼筋砼框架結構設置拉梁層問題 9 3.12施工需特別注意的問題9 3.13其他12 3.14計算結果文件123.14.1結構分析、設計信息輸出文件(wmass.out)123.14.2周
6、期、地震力與振型輸出文件(wzq.out)193.14.3結構位移輸出文件(wdisp.out)303.14.4各層內力標準值輸出文件(wnl*.out、wwnl*.out)353.14.5底層柱、墻最大組合內力(wdcnl.out)493.14.6混凝土構件配筋、鋼構件驗算輸出文件(wpj*.out)563.14.7超筋超限信息(wgcpj.out)913.14.8樓層地震作用調整信息(wv02q.out)923.14.9各層配筋構件編號簡圖 933.14.10混凝土構件配筋及鋼構件驗算簡圖 933.14.11梁彈性撓度、柱軸壓比、墻邊緣構件簡圖 933.14.12各荷載工況下構件標準內力簡
7、圖 933.14.13梁設計內力包絡圖 933.14.14梁設計配筋包絡圖 934.結論 945.致謝 956.參考文獻 967.附錄 971. 設計原始資料及條件 1.1 設計原始資料 1.1.1 建設地點 該工程位于成都市市區某高校內。 1.1.2 建筑物主要功能 建筑物主要功能為住宿,盥洗、管理等用房于一體,建筑面積4000m2左右。主要結構形式采用框架結構。 1.2 設計條件 1.2.1 水文地質條件 擬建場地地形平坦,場區地質情況規整,無不良工程地質現象,場地穩定性好,宜于建筑。屬岷江系府河i級階上,地層為地四系全新統至上更新統,屬ii類場地,地基土分布均勻,自地表向下依次為:耕作土
8、0.7米;粘性土6.6米(fk=180kpa,r=18kn/m3), 其下為礫卵石土層,樁端極限端阻力標準值為4500kpa。可不考慮地下水的影響。擬建物可采用天然基礎,基礎形式為條形基礎,建議以粘性土作為擬建物基礎持力層,建議基礎埋置深度為1.5米。 1.2.2 氣象條件 該地區主導風向為東北風,基本風壓w0=0.30kn/m2;基本雪壓s0=0.10kn/m2。 1.2.3 抗震設防 抗震設防烈度為7度,設計基本地震加速度值0.10g,設計地震分組為第三組,遠震。 1.2.4 其他條件 該工程所需的預制構件及其它材料均可保證供應;水電供應有保證,有較強的施工力量及各種施工機械。2. 建筑初
9、步設計說明書 2.1 工程設計依據 2.1.1 成都大學本科畢業設計(論文)任務書 2.1.2 本畢業設計(論文)所遵循的主要規范和規程 2.2 工程概況本工程為某高校學生宿舍。工程為五層現澆鋼筋混凝土框架結構。工程所在地抗震設防烈度為7度,設計基本地震加速度為0.20g,設計地震分組為第一組,場地類別為類。屋面做法:鋼筋混凝土現澆板,20mm石灰砂漿抹底,20mm水泥砂漿找平,80160厚(3%找坡)膨脹珍珠巖保溫層,四層作法防水層(一氈二油上鋪小石子)。樓面做法:鋼筋混凝土現澆板,20mm石灰砂漿抹底,20mm水泥砂漿找平,水磨石面層。墻身做法:由普通磚砌筑而成,普通磚自重18kn/m3,
10、厚度240mm。門窗做法:門為木門,自重0.2 kn/m2,窗為鋼窗玻璃窗,自重0.4 kn/m2。活荷載:上人屋面均布活荷載標準值2.0kn/m2,樓面活荷載標準值2.0kn/m2。常年主導風向為東北風,基本風壓650n/m2,年最高溫度38,最低溫度0。年降水量:624.0mm,日最大降水量92.3mm地基情況:表面為0.5米原耕種土。下為濕陷性黃土,地耐力標準值為 2.3設計特點 2.4防火與疏散設計 2.4.1 防火設計 2.4.1.1 建筑分類 本工程屬于二類公共建筑,建筑總高度小于24m,執行建筑設計防火規范gb50016-2006,防火設計建筑分類為二類,耐火等級為二級。 2.4
11、.1.2 自動滅火系統設置 在每層樓房間及走道設置自動噴水系統,與時代接軌,此外在走道上隔距設置消火栓,確保突發狀況能夠安全應對。 2.4.1.3 防排煙設施 由于本工程走道較長,一旦發生火災將會阻礙煙霧排出,嚴重影響疏散速度,故走道每隔20m設置機械防、排煙系統。 2.4.1.4 火災報警設施 每間學生宿舍設置火災探測器(走道一般無可燃物,校方可根據資金狀況決定是否在走道安裝探測器)。 2.4.1.5 防火材料 樓地面,墻面及天棚裝修材料均采用燃燒性能等級為a級的建筑材料,或采用符合工程建設標準強制性條文中燃燒性能等級要求的建筑裝飾材料。 2.4.2 疏散設計 合理設計疏散樓梯布局,分別位于
12、建筑物兩側,確保了每個分隔區域至少有兩個樓梯可以直達地面,此外疏散樓梯根據本工程的建筑面積及學生公寓一般入住率計算人數,根據人流量進行了樓梯長寬布置。 2.5 標高 本工程室內標高0.000相當于絕對標高,室內外高差為0.500m,絕對標高由現場定。各層柱注的標高為建筑完成面標高,屋面標高為結構面標高。本工程標高以m為單位,其它尺寸以mm為單位。 2.4 土方工程 2.5 墻體工程 2.5.1 內墻采用普通機制磚填充墻,m5混合砂漿砌筑,“803”內墻涂料兩度。衛生間、陽臺墻面貼白色瓷磚,高至板底。2.5.2 外墻采用普通機制填充墻,m5混合砂漿砌筑,1:3水泥砂漿抹底,20厚,陶瓷錦磚貼面。
13、2.5.3 墻身防潮20厚1:2水泥砂漿加5%防水劑,詳見西南04jii2。遇地面有高差時沿墻身迎土面設豎向防潮層與水平防潮層形成閉合。2.6 樓地面2.6.1 樓面類型采用水泥豆石樓面。2.6.2 排水凡設有地漏或出水口的樓地面均做1%坡度,坡向地漏或出水口。2.6.3 防水衛生間及其他用水房間的地面需進行防水處理,墻體基腳均用c30素砼現澆高,寬度同墻厚,加做一道防水層:高分子防水涂料2.5mm,墻地交界處垂直向上延伸300mm高,衛生間墻地交界處垂直向上延伸1800mm高。2.6.3 其他管道穿樓板處應填塞密實防水材料嵌縫處理,樓面防水層反上300高。管道井每層用相當于樓板耐火極限的不燃
14、材料封堵。底層地面墊層橫縱向縮縫詳西南04j312-7。2.7 門窗2.7.1 氣密性本工程外窗氣密性為3級。2.7.2 相關規定門窗玻璃的選用應遵照建筑玻璃應用技術規程和建筑安全玻璃管理規定發改運行20032116號及地方管理部門的有關規定。2.7.3 過梁問題門窗頂無框架梁者,當門窗洞口寬度b1000時做磚過梁,1000b1.5m的窗玻璃,易遭受撞擊、沖擊而造成人體傷害的其他部位。2.8 建筑節能2.9 其他圖中所選用標準圖中有對結構工種的預埋件、預留洞,如鋼結構樓梯、金屬欄桿、門窗、建筑配件等,以及本圖所標注的各種留洞和預埋件應與各工種密切配合,確認無誤后方可施工。施工中應強調土建與設備
15、安裝之間的密切配合,除按施工圖選用的標準圖及設備產品說明等要求進行施工外,還應嚴格按照國家相關施工規范規程進行施工,并做好隱蔽工程的記錄。如發現圖紙矛盾,應及時與設計單位協商解決,嚴禁擅自更改、隱瞞,避免出現嚴重的工程質量問題和設計意圖受到破壞。預埋木磚及貼鄰墻體的木質面均做防腐處理,露明鐵件均做防銹處理。二次裝修材料不得降低原建筑材料的耐火等級;二次裝修不得影響消防設施的正常使用。施工圖中的房間功能不得任意變更,若確有需要,必須先通知設計單位并確認同意。施工過程中應嚴格執行國家各項施工質量驗收規范。3.結構計算書3.1 工程概況 本工程學生公寓位于成都市某大學內,其功能是為學校學生提供住所。
16、該工程為多層現澆鋼筋混凝土框架結構,共五層,底層層高3.3米,其他層層高均為3.3米,建筑物總高度為18.5米,總建筑面積為4022.15平方米。4人間設計,有獨立的衛生間和陽臺,能滿足四百多人同時入住。3.2 設計依據3.2.1 學生公寓規范根據學生公寓建筑設計規范gbj3899要求,該公寓建筑方案設計考慮到了學生上課、休息、娛樂等多方面。3.2.2 學生公寓選址和總平面布置公寓位置適中、交通方便、環境安靜、工程地質及水文地質條件都為較有利的地段;總平面布置功能分區明確、總體布局合理、各區聯系方便、互不干擾,并留有發展用地; 交通組織考慮到了人、車分流,道路布置,便于學生進出及消防疏散。3.
17、2.3 國家規范和行業標準分別依據以下國家規范和行業標準進行設計:房屋建筑制圖統一標準gbt500012001 ;建筑制圖標準gb/t50104-2001;建筑結構制圖標準 gb/t 501052001;圖書館建筑設計規范jgj38-99;工程建設標準強制性條文(房屋建筑部分2002年版);建筑設計防火規范gb500162006;建筑工程抗震設防分類標準gb50223-2008;民用建筑設計通則gb503522005;建筑結構荷載規范gb500092001(2006年版);混凝土結構設計規范gb500102002;建筑抗震設計規范gb500112001(2008年版);砌體結構設計規范gb50
18、0032001;建筑地基基礎設計規范 gb500072002;土木工程專業畢業設計指導。3.2.4 設計手冊參考以下手冊:建筑設計資料集(第2、4、8集);建筑結構靜力計算手冊;混凝土結構設計手冊;砌體結設構計手冊;建筑抗震設計手冊等。3.2.5 標準圖集 混凝土結構施工圖平面整體表示方法制圖規則和構造詳圖(圖集號03g101-1);建筑物抗震構造詳圖(圖集號03g329-1);建筑物抗震構造詳圖03g3291 ;西南地區相關圖集等。3.3 圖紙說明3.4 建筑分類等級3.4.1 安全等級本工程建筑結構安全等級為二級。3.4.2 耐火等級本工程耐火等級為二級。3.5 主要荷載(作用)取值上人屋
19、面:2.0 kn/;宿舍:2.0kn/;宿管休息室:2.0kn/;管理室:2.0kn/;陽臺:2.0kn/;廁所:2.0kn/;走廊:2.5 kn/;樓梯間:2.5kn/;不上人屋面:0.5kn/3.6 設計建設程序3.7 主要結構材料3.7.1 混凝土梁、板、柱混凝土等級均采用c30。3.7.2 鋼筋梁、柱主筋采用熱軋級鋼筋,箍筋采用熱軋級鋼筋,板、樓梯構件及非主結構構件采用冷軋級鋼筋。3.7.3 砌體本工程采用全現澆施工工藝。3.8 樓蓋設計3.8.1樓面做法: 鋼筋混凝土現澆板,20mm石灰砂漿抹底,20mm水泥砂漿找平,水磨石面層。 3.8.2樓面荷載: 均布活荷載標準值2kn/m2
20、3.8.3材料: 混凝土強度等級為c30;梁內受力縱筋為hrb335,其余為hpb235鋼筋 3.8.4 樓蓋的結構平面布置圖 見下圖 3.8.5截面設計 截面有效高度:假定選用8鋼筋,則l01方向跨中截面的h01=80mm;l02方向跨中截面的 h02=70mm; 支座截面h0=80mm。 最小配筋率smin=0.27%,則asmin=0.27%1000100=270mm2 截面設計時取用的彎矩設計值:中間跨的跨中截面及中間支座截面減小20%;邊跨跨中截面 及樓板邊緣算起的第二個支座截面處,當lb/l01.5時減小20%,當lb/l0=1.52.0時減小10%; 樓板的角區格不折減。 3.8
21、.6 次梁的設計 次梁l跨度7.2m,次梁截面高度h=l/18l/12=7200/187200/12=400mm600mm,取 h=600mm,截面寬度取b=200mm。 荷載設計值板傳來的荷載p=2pe=23.76kn/m次梁自重0.2(0.6-0.1)251.2=3kn/m次梁粉刷0.02(0.6-0.1)2+0.2171.2=0.5kn/m填充墻自重和粉刷 0.24(3.3-0.6) 18+0.022(3.3-0.617) 2=15.34 kn/m則荷載總設計值g+q=42.6kn/m 3.9 恒荷載計算 3.9.1屋面框架梁線荷載標準值 20厚水泥沙漿找平0.0220=0.40kn/m
22、2 80160厚(3%找坡)膨脹珍珠巖(0.08+0.16)27=0.84kn/m2 四層作法防水層 0.36kn/m2 100mm厚鋼筋混凝土樓板 0.125=2.5kn/m2 20mm厚石灰砂漿抹底 0.0217=0.34kn/m2 屋面恒荷載 4.44 kn/m2 邊框架梁自重 0.30.825=6kn/m 邊框架梁粉刷 2(0.8-0.1)0.0217=0.48kn/m 中框架梁自重 0.30.625=4.5kn/m2 中框架梁粉刷 2(0.6-0.1)0.0217=0.34kn/m 則作用于屋面框架梁上線荷載標準值為: g5ab1=6.48kn/m g5bc1=4.84kn/m g5
23、ab2=4.443.6=15.98kn/m g5bc2=4.442.4=10.66kn/m 3.9.2樓面框架梁線荷載標準值 20mm厚水泥砂漿找平 0.0220=0.40kn/m2 100mm厚鋼筋混凝土樓板 0.125=2.5kn/m2 20mm厚石灰砂漿抹底 0.0217=0.34kn/m2 水磨石面層 0.65 kn/m2 樓面恒荷載 3.89 kn/m2 邊框架梁自重及粉刷 6.48kn/m 中框架梁自重及粉刷 4.84kn/m 邊跨填充墻自重 0.24(3.3-0.8)18=10.8kn/m 填充墻粉刷 (3.3-0.8)0.02217=1.7kn/m 則作用于樓面框架梁上線荷載標
24、準值為: gab1=6.48+10.8+1.7=18.98kn/m gbc1=4.84kn/m gab2=3.893.6=14.00kn/m gbc2=3.892.4=9.34kn/m 3.9.3屋面框架節點集中荷載標準值 縱向框架梁自重 0.30.87.225=43.2kn 縱向框架梁粉刷 2(0.8-0.1)0.027.217=3.43kn 縱向框架梁傳來的屋面恒荷載 2(3.6/2)24.44=28.77kn 次梁自重及粉刷 0.60.2257.2/2+20.02(0.6-0.1)7.2/2=10.87kn 次梁傳來的屋面恒荷載 (1-20.252+0.253)4.443.67.2/2=
25、51.25kn 1m高女兒墻自重及粉刷 17.20.2418+217.20.0217=36kn 則頂層邊節點集中荷載為:g5a=176.52kn 縱向框架梁自重及粉刷 43.1+3.43=46.63kn 縱向框架梁傳來的屋面恒荷載 28.77+(1-20.172+0.173)4.447.22.4/2=65.10kn 次梁自重、粉刷及傳來的屋面恒荷載 10.87+51.25=62.12kn 則頂層中節點集中荷載為:g5b=173.85kn 3.9.4樓面框架節點集中荷載標準值 縱向框架梁自重及粉刷 46.63kn 縱向框架梁傳來的樓面恒荷載 2(3.6/2)23.89=25.21kn 次梁自重及
26、粉刷 10.87kn 次梁傳來的樓面恒荷載 (1-20.252+0.253)3.893.67.2/2=44.9kn 鋼窗自重 (21.01.7+1.22.6) 0.42=5.216kn 墻體自重 (3.37.2-6.52)0.2418=74.48kn 墻面粉刷 2(3.37.2-6.52)0.0217=13.07kn 框架柱自重 0.5023.325=20.63kn 柱面粉刷40.50.0217=0.68kn 中間層邊柱節點集中荷載為:ga=241.69kn 縱向框架梁自重及粉刷 46.63kn 縱向框架梁傳來的樓面恒荷載25.21+(1-20.172+0.173)3.897.22.4/2=5
27、7.04kn 次梁粉刷、自重及傳來的樓面恒荷載 10.87+44.9=55.77kn 木門自重 21.02.60.2=1.04kn 墻體自重 (3.37.2-5.2)0.2418=80.18kn 墻面粉刷 20.02(3.37.2-5.2)17=12.62kn 框架柱自重及粉刷 20.63+0.68=21.31kn 中間層中柱節點集中荷載為:gb=274.59kn3.10 樓梯設計3.10.1 梯斷板樓梯踏步尺寸150mm300mm,板厚120mm,tan=150/300=0.5,cos=0.894取1m寬板帶計算 恒載 水磨石面層 (0.3+0.15)0.65/0.3=0.98 kn/ 三角
28、形踏步 0.50.30.1525/0.3=1.88 kn/ 混凝土斜板 0.1225/0.894=3.36 kn/ 20厚板底抹灰 0.0217/0.894=0.38 kn/ 合計: 6.6 kn/3.10.2平臺板設平臺板厚100mm恒載 水磨石面層 0.65 kn/100厚混凝土板 0.125=2.5 kn/ 20厚板底抹灰 0.0217=0.34 kn/ 合計:3.49 kn/ 3.10.3平臺梁設平臺梁截面尺寸為200mm350mm恒載 梁自重 0.2(0.35-0.1)25=1.25 kn/m 梁側粉刷 2(0.35-0.1)0.0217=0.17 kn/m 0.1564平臺板傳來
29、3.491.6/2=2.792 kn/m 4.788/3.192梯段板傳來 6.63.3/2=10.89 kn/m 合計:15.102 kn/m 3.11基礎設計 3.11.1基礎臺階的寬高比和偏心距控制 基礎平面長寬比控制接近矩形,獨立基礎是以柱為固定端四面挑出的懸臂板; 基礎臺階的寬高比2.5;基礎有一定的抗彎剛度,確保地基反力線性分布; 基礎的偏心距eb/6保證基底面積上的地基反力pmin0; 上述條件成立,才能近似地將地基反力設計值按對角線劃分,兩全方向的彎矩mi和mii等于梯形基底面枳上地基反力設計值在計算截面產生的彎矩 3.11.2 獨立基礎的最小配筋率 目前工程做法列表: 目前工
30、程做做法 1 2 3 4每m寬配筋 1000h0.15%1000hz0.15% 1000h10.15%最小構造配筋 10200 10200 10200 10200實配 上兩值與計算值取大值 3.11.3 柱縱向受力筋的插筋在基礎內的錨固長度 1當(1)柱為軸心受壓或小偏心受壓,基礎高度1200mm;(2)柱為大偏心受壓,基礎高度1400mm時,可只將柱四角插筋伸至基礎底鋼筋網上直角彎勾錨固(直鉤長6d,150mm) 2 當柱插筋在基礎內保護層厚度3d,且柱在基礎內有箍筋時(圖4),柱插筋最小錨固長度可取0.8(laor,lae); 3 當基礎高不滿足插筋錨固長度要求時可直鉤彎折,要求直線段長0
31、.5(la或,lae),直鉤長=12d. 3.11.4獨立柱基間拉梁 1抗規規定獨立柱基在下情況之一時,應設拉梁: 1)一級框架和 iv類場地的二級框架; 2)各柱基承受的重力荷載代表值差別大; 3)基礎埋置深,或各基礎埋置深度差別大; 4)地基主要受力層范圍內存在軟弱下臥層、液化層和嚴重不均勻沉降土層; 5)少于3樁的樁基承臺間及兩樁承臺軸線垂直方向(包括程序自動生成兩樁承臺因碰撞而旋轉90度的情況)。 3 無5.1情況且柱距較大(如單跨廠房、體育館、影劇院、餐廳等)沒必要設拉梁,拉梁剛度小, 4 拉梁應有一定剛度,截面高度取(1/51/20)l,寬度取(1/251/35)l,l為柱間距;
32、5 拉梁位置除在樁基承臺上,宜靠近首層地面. 6 拉梁的計算模型及配筋 1) 作為軸心受拉構件,軸拉力f=較大柱軸力的1/10;上下均配214,箍筋6200; 2) 平衡柱底彎矩,柱基按中心受壓計;拉梁正彎矩鋼筋全拉通,支座負彎矩筋1/2拉通;粱高取5.4中大值; 3) 拉梁當一層樓進行整體計算.,取較大柱軸力的1/10+整體計算內力配筋,彎矩設計值增大系數在拉梁層取1.0。 3.11.5 多層鋼筋砼框架結構設置拉梁層問題 多層鋼筋砼框架結構底層層高較高,為滿足抗震設計層間位移角要求,常采用短柱基礎或設置拉梁層解決;拉梁層的處理: 1 拉梁層的拉梁應按框架梁設計,梁按相應抗震等級設置箍筋加密區
33、; 2 拉梁層無樓板,在pkpm前處理時房間開洞,計算時定義彈性膜,總剛分析; 3 如實輸入拉梁上的荷載; 4 設拉梁層時,按框架嵌固于基礎面和一層地下室,回填土對地下室約束剛度比取”1”各算一次,配筋取大值; 5 拉梁層柱配筋按層上下柱配筋大值;拉梁層柱箍筋抗震設計時密箍. 3.12施工需特別注意的問題 施工中需要注意的問題在施工前,必須仔細查閱其他專業的施工圖紙,尤其是土建結構施工圖、水、電、通風施工圖。因為水平路由的長短將會對系統的等級有一定的影響,而土建結構施工圖、水、電、通風施工圖對水平布線子系統管線路由的走向影響最大。可利用autocad繪出三維大樣圖,在大樣圖上注明其它專業管路的
34、走向、標高以及各種管路的規格型號,制定出最優敷設管路的施工方案,滿足管線路由最短,便于安裝的要求。目前水平布線有三種方法:鋼管暗敷設法、吊頂內走線槽,線槽至信息點之間采用鋼管連接方法、地面線槽暗敷設法,其中地面線槽暗敷設法適用于較高檔的智能大廈。大廈內布置的信息點密集、大開間需要打隔斷的辦公場所,它的特點是投資比較大,工藝要求高,施工比較困難。良好的安裝質量,可以使水平布線子系統在其工作周期內,始終保證良好工作狀態和穩定的工作性能,尤其對于高性能的通信線纜和光纖,安裝質量的好壞對系統的開通影響尤其顯著,因此筆者認為在安裝線纜中,要嚴格遵守eia/tia569規范標準。綜合布線系統所選用的線纜、
35、信息插座、跳線、連接線等部件,必須與選擇的類型一致,如選用5類標準,則線纜、信息插座、跳線、連接線等部件必須為5類;如系統采用屏蔽措施,則系統選用的所有部件均為屏蔽部件,只有這樣才能保證系統屏蔽效果,達到整個系統的設計性能指標。地面金屬線槽施工技術地面金屬線槽布線是為了適用智能大廈弱電系統日趨復雜,出線口位置變化不定,而推出的一種新型的布線方式。地面金屬線槽分為單槽、雙槽、三槽和四槽,規格有5025、7025、10025、12525。地面金屬線槽敷設時,電氣專業應與土建專業密切配合,結合施工圖出線口的位置,線槽的走向,確定分線盒的位置。線槽在交叉、轉彎或分支處應設置分線盒,線槽的長度超過6米時
36、,應加分線盒。設備間配線架、集線器、配電箱等設備引至線槽的線路,用終端變形連接器與線槽連接。線槽每隔2米處設置固定支架和調整支撐,并與鋼筋連接防止移位。線槽的保護層應達到35mm以上,線槽連接完后應進行整體調整,請采用測量工具進行復核,嚴禁地面線槽超高。連接器、分線盒、線槽接口處應用密封條粘貼好,防止砂漿滲入腐蝕線槽內壁。在連接線槽過程中,出線口、分線盒應加防水保護蓋,待底板的混凝土強度達到50%時,取下保護蓋換上標識蓋。施工中,應用鋼銼對金屬線槽的毛刺銼平,否則會劃傷雙絞線的外皮,使系統的抗干擾性、數據保密性、數據傳輸速度降低,甚至導致系統不能順利開通。線纜的敷設水平布線子系統要求在90m的
37、距離范圍內,這個距離范圍是指從樓層接線間的配線架到工作區的信息點的實際長度。與水平布線子系統有關的其它線纜,包括配線架上的跳線和工作區的連線總共不應超過90m。一般要求跳線長度小于6m,信息連線長度小于3m。由于地面內暗敷金屬線槽,所以它的散熱條件比明敷線槽效果好。控制、信號線路為非載流線纜,不存在因散熱效果不好而使線纜損壞的問題。因此雙絞線纜在線槽內的填充率可達到線槽截面的50%。同一回路的所有雙絞線纜可在同一線槽內敷設。強、弱電線纜應分槽敷設,兩種線路交叉處應設置有屏蔽分線板的分線盒。線纜不得有接頭,接頭應在分線盒或線槽出線盒內處理。配線子系統電纜在地板下的安裝方式,應根據環境條件選用地板
38、下橋架布線法、蜂窩狀地板布線法、高架(活動)地板布線法、地板下管道布線法等四種安裝方式。配線子系統電纜宜穿鋼管或沿金屬電纜橋架敷設,并應選擇最短捷的路徑。干線子系統垂直通道有電纜孔、管道、電纜豎井等三種方式可供選擇,宜采用電纜孔方式。水平通道可選擇管道方式或電纜橋架方式。一根管子宜穿設一條綜合布線電纜。管內穿放大對數電纜時,直線管路的管徑利用率宜為 50%60%,彎管路的管徑利用率宜為 40%50%。管內穿放4對對絞電纜時,截面利用率宜為25%30%。允許綜合布線電纜、電纜電視電纜,火災報警電纜,監控系統電纜合用金屬電纜橋架,但與電纜電視電纜宜用金屬隔板分開。建筑物內暗配線一般可采用金屬配線材
39、料或塑料管。由于金屬的配線材料有屏蔽作用,與強電(220v以上)管線平行或交叉可以減少隔距要求,因此是首推方式。設備安裝工藝設備間1.設備間的設計應符合下列規定:設備間應處于干線綜合體的最佳網絡中間位置,應盡可能靠近建筑物電纜引入區和網絡接口。電纜引入區和網絡接口的相互間隔宜15m;設備間的位置應便于接地裝置的安裝;設備間室溫應保持在 1027之間,相對濕度應保持 30%80%。設備間應安裝符合法規要求的消防系統,應使用防火防盜門,至少能耐火1小時的防火墻;設備間內所有設備有足夠的安裝空間,其中包括:程控數字用戶電話交換機,計算機主機,整個建筑物用的交接設備等。2.設備間的室內裝修、空調設備系
40、統和電氣照明等安裝應在裝機前進行。設備間的裝修應滿足工藝要求,經濟適用。容量較大的機房可以結合空調下送風、機架間走纜和防靜電等要求,設置活動地板。3.設備間應防止有害氣體(如so2、 h2s、 nh3、 no2等)侵入,并應有良好的防塵措施(灰塵粒子應是不導電的,非鐵磁性和非腐蝕性的)。4.至少應為設備間提供離地板2.55m高度的空間,門的高度應大于2.lm,門寬應大于90cm,地板的等效均布負載應大于5kn/m2。凡是安裝綜合布線硬件的地方,墻壁和天棚應涂阻燃漆。5.設備間的一般照明,最低照度標準應為150ix,規定照度的被照面,水平面照度指距地面0.8m處,垂直面照度指距地面1.4m處的規
41、定。交接間1.確定干線通道和交接間的數目,應從所服務的可用樓層空間來考慮。如果在給定樓層所要服務的信息插座都在75m范圍以內,宜采用單干線接線系統。凡超出這一范圍的,可采用雙通道或多個通道的干線系統,也可采用經過分支電纜與干線交接間相連接的二級交接間。2.干線交接間兼作設備間時,其面積不應小于10m2。干線交接間的面積可按78倍配線柜占地面積考慮。3.配線設備靠墻安裝干線交接間的面積為1.8m2時(1.2m1.5m)可容納端接200個工作區所需的連接硬件和其它設備。綜合布線的防護接地系統接地技術綜合布線系統采用屏蔽措施時,應保證有優良好的接地系統,可單獨設置接地體,接地電阻4;采用聯合接地體時
42、,接地電阻1。綜合布線系統所用屏蔽層必須保持連續性,并保證線纜的相對位置不變,屏蔽層的配線設備端應接地。采用屏蔽綜合布線系統時 屏蔽層的配線設備 fd或bd 端必須良好接地 用戶端 終端設備 視具體情況接地 兩端的接地應連接至同一接地體。若接地系統中存在兩個不同的接地體時 其接地電源差不應大于1vrms 有效值采用屏蔽布線系統時 每一樓層的配線柜都應采用適當截面的銅導線單獨布線至接地體 也可采用豎井內集中用銅排或粗銅線引到接地體 導線或銅導體的截面應符合標準。接地導線應接成樹狀結構的接地網 避免構成直流環路。信息插座的接地可利用電纜屏蔽層連至每層的配線柜上。工作站的外殼接地應單獨布線連接至接地
43、體 一個辦公室的幾個工作站可合用同一條接地導線 應選用截面不小于25mm2的絕緣銅導線。屏蔽線纜屏蔽層接地兩端測量鏈路屏蔽線、屏蔽層與兩端接地電流差5v。防護技術當電纜從建筑物外面進入建筑物內部容易受到雷擊、電源碰地、電源感應電勢或地電勢上浮等外界影響時必須采用保護器。在下述的任何一種情況下線路均屬于處在危險環境之中均應對其進行過壓過流保護。1.雷擊引起的危險影響;2工作電壓超過250v的電源線路碰地;3地電勢上升到 250v以上而引起的電源故障;4交流50hz感應電壓超過250v。5綜合布線系統的過壓保護宜選用氣體放電管保護器。6過流保護宜選用能夠自復的保護器。7在易燃的區域或大樓豎井內布放的光纜或銅纜必須有阻燃護套;當這些纜線被布放在不可燃管道里或者每層樓都采用了隔火措施時則可以沒有阻燃護套。綜合布線系統有源設備的正極或外殼電纜屏蔽層及連通接地線均應接地宜采用
溫馨提示
- 1. 本站所有資源如無特殊說明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請下載最新的WinRAR軟件解壓。
- 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請聯系上傳者。文件的所有權益歸上傳用戶所有。
- 3. 本站RAR壓縮包中若帶圖紙,網頁內容里面會有圖紙預覽,若沒有圖紙預覽就沒有圖紙。
- 4. 未經權益所有人同意不得將文件中的內容挪作商業或盈利用途。
- 5. 人人文庫網僅提供信息存儲空間,僅對用戶上傳內容的表現方式做保護處理,對用戶上傳分享的文檔內容本身不做任何修改或編輯,并不能對任何下載內容負責。
- 6. 下載文件中如有侵權或不適當內容,請與我們聯系,我們立即糾正。
- 7. 本站不保證下載資源的準確性、安全性和完整性, 同時也不承擔用戶因使用這些下載資源對自己和他人造成任何形式的傷害或損失。
最新文檔
- 續簽勞動合同的文書準備
- 資源開發效率評估-全面剖析
- 2024年中山市高校畢業生“三支一扶”計劃招募筆試真題
- 情感化導覽系統的設計路徑-全面剖析
- 皮革電商市場潛力分析-全面剖析
- 2024年淮南市招聘村級后備干部筆試真題
- 中和試驗快速檢測材料-全面剖析
- 2024年德陽市旌陽區衛生事業單位招聘專業技術人員筆試真題
- 2024年安徽建工集團招聘筆試真題
- 美術館藏品保護技術-全面剖析
- 廣州小學六年級英語下冊知識點歸納和習題(全冊)
- 節能評審和節能評估文件編制費用收費標準
- 2023-2024年《勞務勞動合同樣本范本書電子版模板》
- 中國居民口腔健康狀況第四次中國口腔健康流行病學調查報告
- MOOC 數據挖掘-國防科技大學 中國大學慕課答案
- 中藥注射劑合理使用培訓
- 第13課+清前中期的興盛與危機【中職專用】《中國歷史》(高教版2023基礎模塊)
- 2024年國家糧食和物資儲備局直屬事業單位招聘筆試參考題庫附帶答案詳解
- 蘇軾臨江仙課件大學語文完美版
- 《施工測量》課件
- 情緒健康管理服務規范
評論
0/150
提交評論